Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation

被引:18
|
作者
König, A
Schiele, TM
Rieber, J
Theisen, K
Mudra, H
Klauss, V
机构
[1] Med Klin Innenstadt, Univ Hosp, Dept Cardiol, D-80336 Munich, Germany
[2] Stadt Klinikum Neuperlach, Dept Cardiol, Munich, Germany
关键词
stent type; vessel remodeling; neointima formation; restenosis;
D O I
10.1002/ccd.10249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The self-expanding Wallstent (WS) and balloon-expandable Palmaz-Schatz stents (PS) display different mechanical and dynamical stent properties. We analyzed the impact of the respective stent design on coronary wall geometry using quantitative coronary angiography (QCA) and intracoronary ultrasound (ICUS) measurements. Serial measurements were performed within the stent and within reference segments of 50 patients (25 WS, 25 PS). Relative changes for each parameter in both stent designs were calculated (Mann-Whitney U-test; 95% CI). The luminal net gain in WS was not significantly higher in WS compared with PS (1.63 +/- 1.11 vs. 1.44 +/- 0.63 mm; P = 0.2554). The respective loss indexes were also similar (0.38 +/- 0.42 vs. 0.36 +/- 0.23; P = 0.8578). The WS segments showed significant postinterventional stent expansion with positive vessel remodeling. The neointima formation was significantly higher in WS segments (4.23 +/- 2.07 vs. 2.22 +/- 2.22 mm(2)). The coronary wall morphology and stent geometry after 6.5 +/- 1.2 months are related to the stent design. In WS segments, the neointima formation was balanced by postinterventional stent expansion, resulting in a comparable relative lumen loss in both stent types. The respective stent design had no impact on the vessel reference segments.
引用
收藏
页码:478 / 486
页数:9
相关论文
共 50 条
  • [31] Bursting Fracture of Balloon-Expandable Stent and Pseudoaneurysm Formation in the Left Common Iliac Artery and Endovascular Treatment With Graft Stent
    Kim, Min
    Lee, Dae In
    Lee, Ju-Hee
    Lee, Sang Yeub
    Bae, Jang-Whan
    Hwang, Kyung-Kuk
    Kim, Dong-Woon
    Cho, Myeong-Chan
    Kim, Sangmin
    VASCULAR AND ENDOVASCULAR SURGERY, 2018, 52 (07) : 556 - 560
  • [32] Computational modeling of balloon-expandable stent deployment in coronary artery using the finite element method
    Umer, Muhammad
    Ali, Murtaza Najabat
    Mubashar, Aamir
    Mir, Mariam
    RESEARCH REPORTS IN CLINICAL CARDIOLOGY, 2019, 10 : 43 - 56
  • [33] Can a self-expanding pediatric stent expand with an artery? Relationship of stent design to vascular biology
    Nia, Nima V.
    Fishbein, Gregory A.
    Levi, Daniel S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (01) : 139 - 147
  • [34] Long-Term Impact of Balloon Postdilatation on Neointimal Formation: An Experimental Comparative Study Between Second-Generation Self-Expanding Versus Balloon-Expandable Stent Technologies
    Aboodi, Michael S.
    Milewski, Krzysztof
    Tellez, Armando
    Cheng, Yanping
    Yi, Geng-Hua
    Kaluza, Greg L.
    Granada, Juan F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (03) : 397 - 404
  • [35] Coronary artery aneurysm formation after balloon angioplasty and stent implantation
    Berkalp, B
    Kervancioglu, C
    Oral, D
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (01) : 65 - 70
  • [36] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08): : 489 - 495
  • [37] Intravascular Ultrasound Comparison of the Self-Expanding Sideguard Stent in the Side Branch Versus a Balloon-Expandable Stent in the Main Vessel to Assess Mechanisms of Acute Lumen Gain in Bifurcation Lesions
    Ma, Shixin
    Maehara, Akiko
    Hauptmann, Karl E.
    Guagliumi, Giulio
    Valsecchi, Orazio
    Vassileva, Angelina
    Appelman, Yolande
    Sangiorgi, Giuseppe
    Prati, Francesco
    Mintz, Gary S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) : 748 - 754
  • [38] Self-Expanding Versus Balloon-Expandable Stents for Iliac Artery Occlusive Disease The Randomized ICE Trial
    Krankenberg, Hans a
    Zeller, Thomas b
    Ingwersen, Maja a
    Schmalstieg, Josefin c
    Gissler, Hans Martin d
    Nikol, Sigrid e
    Baumgartner, Iris f
    Diehm, Nicolas g
    Nickling, Estell a
    Mueller-Huelsbeck, Stefan h
    Schmiedel, Rainer i
    Torsello, Giovanni j
    Hochholzer, Willibald k
    Stelzner, Christian l
    Brechtel, Klaus m
    Ito, Wulf n
    Kickuth, Ralph o
    Blessing, Erwin p
    Thieme, Marcus q
    Nakonieczny, Jaroslaw r
    Nolte, Thomas s
    Gareis, Ragnar t
    Boden, Harald u
    Sixt, Sebastian f
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (16) : 1694 - 1704
  • [39] In-hospital costs of self-expanding nitinol stent implantation versus balloon angioplasty in the femoropopliteal artery (The VascuCoil trial)
    Greenberg, D
    Rosenfield, K
    Garcia, LA
    Berezin, RH
    Lavelle, T
    Fogleman, S
    Cohen, DJ
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (10) : 1065 - 1069
  • [40] Inhibition of neointima formation by tranilast in pig coronary arteries after balloon angioplasty and stent implantation
    Ishiwata, S
    Verheye, S
    Robinson, KA
    Salame, MY
    de Leon, H
    King, SB
    Chronos, NAF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (05) : 1331 - 1337