ENDOCOM: Implantable wireless pressure sensor for the follow-up of abdominal aortic aneurysm stented

被引:4
|
作者
Menudet, J. -F.
机构
[1] Univ Paris 06, UMR7606, SoC-SYEL, F-75005 Paris, France
[2] Univ Paris 06, UMR 7190, F-75252 Paris 05, France
[3] REO, Team Rocquencourt, INRIA, F-78153 Le Chesnay, France
[4] UMR 6594, Technopole de Chateau Gombert, F-13451 Marseille 13, France
[5] UMR 6600, F-60205 Compiegne, France
[6] Grp Hosp Pitie Salpetriere, F-75013 Paris, France
关键词
RFID pressure sensor; Numerical modelling; AAA; in vivo experiments; ENDOVASCULAR REPAIR; ENDOTENSION; RUPTURE;
D O I
10.1016/j.irbm.2011.01.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An abdominal aortic aneurysm (AAA) is a dilatation of the aorta at the abdominal level, the rupture of which is a life threatening complication with an 80% mortality rate. Even though those devices keep improving, the failure rate of the endovascular treatment is due to persisting pressure into the excluded aneurysmal sac. Since 2005, several integrated sensors have been designed for the follow-up of the AAA treated by a stent. Solutions are based on the use of a single sensor. Thrombus in the excluded AAA can modify the field of pressure when leaks appeared and a network of sensors should be used. We present in this paper the ENDOCOM project that aims to design an implantable pressure sensor that can be used in a network configuration. To validate the new materials, we developed a framework composed of in vitro experiments and in vivo tests on large animal model. Numerical modeling has been investigated from the experimental data to determine the optimal position of sensor. Some results of those different parts are shown in this paper. (C) 2011 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 50 条
  • [21] Follow-up of aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Bravo Soberon, Alberto
    Marti de Garcia, Milagros
    Garzon Moll, Gonzalo
    Rodriguez Vigil, Beatriz
    Allona Krauel, Maria
    Alvarez-Sala Walter, Rodolfo
    ANNALS OF VASCULAR SURGERY, 2008, 22 (04) : 559 - 563
  • [22] Endovascular therapy of abdominal aortic aneurysm:: Results of a mid-term follow-up
    Pitton, MB
    Schweitzer, H
    Herber, S
    Schmiedt, W
    Neufang, A
    Düber, C
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (10): : 1392 - 1402
  • [23] Follow-Up Compliance After Endovascular Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P.
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 809 - 809
  • [24] Endovascular abdominal aortic aneurysm repair: 5-year follow-up results
    Sandford, R. M.
    Bown, M. J.
    Sayers, R. D.
    Fishwick, G.
    London, N. J.
    Nasim, A.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (03) : 372 - 378
  • [25] Abdominal aortic aneurysm in a young child: A 25-year follow-up study
    Clark, N
    Brener, BJ
    JOURNAL OF VASCULAR SURGERY, 1998, 28 (04) : 715 - 718
  • [26] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [27] Inflammatory Abdominal Aortic Aneurysm Endovascular Repair into the Long-Term Follow-Up
    Coppi, Gioacchino
    Rametta, Francesco
    Aiello, Stefano
    Saitta, Giuseppe
    Gennai, Stefano
    Silingardi, Roberto
    ANNALS OF VASCULAR SURGERY, 2010, 24 (08) : 1053 - 1059
  • [28] Follow-up of abdominal aortic aneurysm after endovascular aortic repair: Comparison of volumetric and diametric measurement
    Hahne, J. D.
    Arndt, C.
    Herrmann, J.
    Schoennagel, B.
    Adam, G.
    Habermann, C. R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) : 1187 - 1191
  • [29] Effects of major endoleaks on a stented abdominal aortic aneurysm
    Li, Z
    Kleinstreuer, C
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 59 - 68
  • [30] Endovascular Technique Versus Conventional Replacement for Abdominal Aortic Aneurysm Up to 24 Months of Follow-Up
    De Luca, Ignacio
    Castelli, Mariano
    Pfund, Guillermo
    Alamo, Alejandro
    Auza, Delfina
    Zaefferer, Patricio
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E143 - E144