We assessed aneurysm neck diameter change after endovascular abdominal aortic aneurysm repair (EVAR) and its relationship to stent-graft diameter. Ninety-eight patients with abdominal aortic aneurysm who underwent EVAR were studied with multislice computed tomography following a standardized protocol. A preoperative study and immediate postoperative, 6-month, 1-year, and 2-year follow-up studies were performed. The aneurysm neck was measured from adventitia to adventitia, 6 mm below the lowermost renal artery, in planar images performed perpendicular to the vessel axis (real axial section). Baseline and follow-up neck diameters were compared with stent-graft diameters. For statistical analysis, a one-way analysis of variance with repeated measures was used. Pearson's correlation coefficient was used to examine the correlation between the change in neck diameter and stent-graft diameter. The average neck diameter was 22.38 mm (range 16-32.5) on the preoperative study and 23.35 mm (17-33.9) on the immediate postoperative, 24.35 mm (18.2-34.5) on the 6-month, 24.36 mm (18-34.5) on the 1-year, and 24.39 mm (17.8-35.7) on the 2-year follow-up. The mean device diameter was 24.08 mm (20-32). A significant increase in average neck diameter was found between the preoperative, immediate postoperative control, and 6-month control. There was no significant increase in the average neck diameter between the 6-month, 1-year, and 2-year follow-up. Baseline mean stent-graft oversizing was 1.7 mm, which decreased to -0.31 mm at latest follow-up. Dilation of the neck did not significantly exceed the endograft diameter in 83 cases (87.36%). An enlargement of the infrarenal aneurysm neck occurred during the first 6 months after EVAR. No significant variation in neck diameter occurred between the 6-month and 2-year follow-up visits. In the majority of cases, dilation of the aneurysm neck does not significantly exceed stent-graft diameter and, therefore, is possibly related to the presence of the endograft.
引用
收藏
页码:559 / 563
页数:5
相关论文
共 50 条
  • [1] Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Badran, MF
    Gould, DA
    Raza, I
    McWilliams, RG
    Brown, O
    Harris, PL
    Gilling-Smith, GL
    Brennan, J
    White, D
    Meakin, S
    Rowlands, PC
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (09) : 887 - 892
  • [2] Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair
    Wever, JJ
    Blankensteijn, JD
    Mali, WPTM
    Eikelboom, BC
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 177 - 182
  • [3] Patient preferences for follow-up methods after endovascular repair of abdominal aortic aneurysms
    Engellau, L
    Larsson, EM
    Norgren, L
    [J]. INTERNATIONAL ANGIOLOGY, 2003, 22 (04) : 407 - 413
  • [4] Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?
    Baumueller, Stephan
    Thi Dan Linh Nguyen
    Goetti, Robert Paul
    Lachat, Mario
    Seifert, Burkhardt
    Pfammatter, Thomas
    Frauenfelder, Thomas
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (06) : 1182 - 1189
  • [5] Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?
    Stephan Baumueller
    Thi Dan Linh Nguyen
    Robert Paul Goetti
    Mario Lachat
    Burkhardt Seifert
    Thomas Pfammatter
    Thomas Frauenfelder
    [J]. CardioVascular and Interventional Radiology, 2011, 34 : 1182 - 1189
  • [6] Remodeling of aortic aneurysm and aortic neck on follow-up after endovascular repair with suprarenal fixation
    Tsilimparis, Nikolaos
    Dayama, Anand
    Ricotta, Joseph J., II
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 28 - 34
  • [7] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [8] Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair
    Spanos, Konstantinos
    Karathanos, Christos
    Athanasoulas, Athanasios
    Sapeltsis, Vasileios
    Giannoukas, Athanasios D.
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (04): : 611 - 618
  • [9] Follow-Up Compliance After Endovascular Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P.
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 809 - 809
  • [10] Ultrasound Imaging of Abdominal Aortic Aneurysms: Diagnosis of Aneurysms and Complications and Follow-Up after Endovascular Repair
    Schuster, H.
    Duenser, E.
    Osinger, K.
    Bergmayr, W.
    Fischer-Scholz, U.
    Richter, W.
    Mostbeck, G. H.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2009, 30 (06): : 528 - 543