Follow-up of aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms

被引:18
|
作者
Bravo Soberon, Alberto [1 ]
Marti de Garcia, Milagros [1 ]
Garzon Moll, Gonzalo [1 ]
Rodriguez Vigil, Beatriz [1 ]
Allona Krauel, Maria [1 ]
Alvarez-Sala Walter, Rodolfo [2 ]
机构
[1] Univ Hosp La Paz, Dept Radiol, Madrid 28046, Spain
[2] Univ Hosp La Paz, Dept Pneumol, Madrid 28046, Spain
关键词
D O I
10.1016/j.avsg.2008.01.009
中图分类号
R61 [外科手术学];
学科分类号
摘要
We assessed aneurysm neck diameter change after endovascular abdominal aortic aneurysm repair (EVAR) and its relationship to stent-graft diameter. Ninety-eight patients with abdominal aortic aneurysm who underwent EVAR were studied with multislice computed tomography following a standardized protocol. A preoperative study and immediate postoperative, 6-month, 1-year, and 2-year follow-up studies were performed. The aneurysm neck was measured from adventitia to adventitia, 6 mm below the lowermost renal artery, in planar images performed perpendicular to the vessel axis (real axial section). Baseline and follow-up neck diameters were compared with stent-graft diameters. For statistical analysis, a one-way analysis of variance with repeated measures was used. Pearson's correlation coefficient was used to examine the correlation between the change in neck diameter and stent-graft diameter. The average neck diameter was 22.38 mm (range 16-32.5) on the preoperative study and 23.35 mm (17-33.9) on the immediate postoperative, 24.35 mm (18.2-34.5) on the 6-month, 24.36 mm (18-34.5) on the 1-year, and 24.39 mm (17.8-35.7) on the 2-year follow-up. The mean device diameter was 24.08 mm (20-32). A significant increase in average neck diameter was found between the preoperative, immediate postoperative control, and 6-month control. There was no significant increase in the average neck diameter between the 6-month, 1-year, and 2-year follow-up. Baseline mean stent-graft oversizing was 1.7 mm, which decreased to -0.31 mm at latest follow-up. Dilation of the neck did not significantly exceed the endograft diameter in 83 cases (87.36%). An enlargement of the infrarenal aneurysm neck occurred during the first 6 months after EVAR. No significant variation in neck diameter occurred between the 6-month and 2-year follow-up visits. In the majority of cases, dilation of the aneurysm neck does not significantly exceed stent-graft diameter and, therefore, is possibly related to the presence of the endograft.
引用
下载
收藏
页码:559 / 563
页数:5
相关论文
共 50 条
  • [21] Change in Aortic Neck Diameter after Endovascular Aortic Aneurysm Repair
    Kret, Marcus R.
    Tran, Kenneth
    Lee, Jason T.
    ANNALS OF VASCULAR SURGERY, 2017, 43 : 115 - 120
  • [22] Type II Endoleaks After Endovascular Repair of Abdominal Aortic Aneurysms: Fate of the Aneurysm Sac and Neck Changes During Long-term Follow-up
    Nolz, Richard
    Teufelsbauer, Harald
    Asenbaum, Ulrika
    Beitzke, Dietrich
    Funovics, Martin
    Wibmer, Andreas
    Plank, Christina
    Prusa, Alexander M.
    Lammer, Johannes
    Schoder, Maria
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (02) : 193 - 199
  • [23] Regarding "Remodeling of aortic aneurysm and aortic neck on follow-up after endovascular repair with suprarenal fixation" Reply
    Tsilimparis, Nikolaos
    Ricotta, Joseph J., II
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (03) : 840 - 841
  • [24] Secondary Interventions and Long-term Follow-up after Endovascular Abdominal Aortic Aneurysm Repair
    Geraedts, Anna C. M.
    Mulay, Sana
    Vahl, Anco
    Wisselink, Willem
    Koelemay, Mark J. W.
    Balm, Ron
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 381 - 391
  • [25] Clinical significance of endoleak detected on follow-up CT after endovascular repair of abdominal aortic aneurysm
    Hong, Cheng
    Heiken, Jay P.
    Sicard, Gregorio A.
    Pilgram, Thomas K.
    Bae, Kyongtae T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (03) : 808 - 813
  • [26] Role of Contrast-Enhanced Ultrasound in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Benedetto, Filippo
    Spinelli, Domenico
    La Corte, Francesco
    Pipito, Narayana
    Passari, Gabriele
    De Caridi, Giovanni
    DIAGNOSTICS, 2022, 12 (12)
  • [27] Endovascular abdominal aortic aneurysm repair: 5-year follow-up results
    Sandford, R. M.
    Bown, M. J.
    Sayers, R. D.
    Fishwick, G.
    London, N. J.
    Nasim, A.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (03) : 372 - 378
  • [28] Inflammatory Abdominal Aortic Aneurysm Endovascular Repair into the Long-Term Follow-Up
    Coppi, Gioacchino
    Rametta, Francesco
    Aiello, Stefano
    Saitta, Giuseppe
    Gennai, Stefano
    Silingardi, Roberto
    ANNALS OF VASCULAR SURGERY, 2010, 24 (08) : 1053 - 1059
  • [29] Towards individualized follow-up protocols after endovascular aortic aneurysm repair
    Laturnus, Johanna
    Oliveira, Nelson
    Basto Goncalves, Frederico
    Schurink, Geert W.
    Verhagen, Hence
    Jacobs, Michael J.
    Mees, Barend M. E.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (02): : 242 - 247
  • [30] Early changes in abdominal aortic aneurysm diameter after endovascular repair
    Farner, MC
    Carpenter, JP
    Baum, RA
    Fairman, RM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (02) : 205 - 210