Follow-up of abdominal aortic aneurysm after endovascular aortic repair: Comparison of volumetric and diametric measurement

被引:9
|
作者
Hahne, J. D. [1 ]
Arndt, C. [1 ]
Herrmann, J. [1 ]
Schoennagel, B. [1 ]
Adam, G. [1 ]
Habermann, C. R. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Radiol & Endoscopy, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
关键词
Angiography; EVAR; CTA; Volume; Diameter; ENDOLEAKS; SAC; MANAGEMENT; EVAR;
D O I
10.1016/j.ejrad.2011.03.065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the correlation of maximal diameter measurements with volumetric evaluation of size after endovascular aortic repair (EVAR) of abdominal aortic aneurysms (AAA) using computed tomography angiography (CTA) and to survey its applicability for clinical follow-up. Materials and methods: 73 consecutive patients (2 females, 71 males; age 38-84 years; mean age, 69.1 +/- 8 years) with AAA were treated with percutaneous EVAR in a single institution. For follow-up, CTA was performed periodically after EVAR. Images were evaluated for maximal diameter in consensus by two experienced radiologists. Using OsirixTM, volumetric measurements were done by one radiologist, including the entire infrarenal abdominal aorta. Results: In 73 patients 220 CTA examinations were performed after EVAR with a mean follow-up of 17.3 months (range, 1.8-42.7 months). The mean postinterventional volume of aneurysm was 165.63 ml +/- 93.29 ml (range, 47.94-565.67 ml). The mean maximal postinterventional diameter was 5.91 +/- 1.52 cm (range, 3.72-13.82 cm). At large over the entire observation period a slight, non-significant decrease of 1.6% (2.58 ml +/- 69.05 ml, range 82.82-201.92 ml) in volumes and a 9.3% (mean 0.55 cm +/- 1.22 cm, range 2.85-1.93 cm) in diameters were observed. For all examinations a high correlation of volume and diameter was calculated (r = 0.813-0.905; alpha < 0.01). Conclusion: For follow-up of abdominal EVAR using CTA there is a high correlation between volumetric and diametric measurements of aneurysm. Based on a daily clinical routine setting, measurements of maximal diameters in cross sectional imaging of AAA after EVAR seems to be sufficient to exclude post interventional enlargement. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1187 / 1191
页数:5
相关论文
共 50 条
  • [1] Endovascular Abdominal Aortic Aneurysm Repair: Nonenhanced Volumetric CT for Follow-up
    Bley, Thorsten A.
    Chase, Peter J.
    Reeder, Scott B.
    Francois, Christopher J.
    Shinki, Kazuhiko
    Tefera, Girma
    Ranallo, Frank N.
    Grist, Thomas M.
    Pozniak, Myron
    [J]. RADIOLOGY, 2009, 253 (01) : 253 - 262
  • [2] Comparison of Volumetric and Diametric Analysis in Endovascular Repair of Descending Thoracic Aortic Aneurysm
    Nomura, Y.
    Sugimoto, K.
    Gotake, Y.
    Yamanaka, K.
    Sakamoto, T.
    Muradi, A.
    Okada, T.
    Yamaguchi, M.
    Okita, Y.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (01) : 53 - 59
  • [3] Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair
    Wever, JJ
    Blankensteijn, JD
    Mali, WPTM
    Eikelboom, BC
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 177 - 182
  • [4] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [5] Follow-Up Compliance After Endovascular Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P.
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 809 - 809
  • [6] Follow-up of aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Bravo Soberon, Alberto
    Marti de Garcia, Milagros
    Garzon Moll, Gonzalo
    Rodriguez Vigil, Beatriz
    Allona Krauel, Maria
    Alvarez-Sala Walter, Rodolfo
    [J]. ANNALS OF VASCULAR SURGERY, 2008, 22 (04) : 559 - 563
  • [7] Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair
    Spanos, Konstantinos
    Karathanos, Christos
    Athanasoulas, Athanasios
    Sapeltsis, Vasileios
    Giannoukas, Athanasios D.
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (04): : 611 - 618
  • [8] Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm
    Elkouri, S
    Panneton, JM
    Andrews, JC
    Lewis, BD
    McKusick, MA
    Noel, AA
    Rowland, CM
    Bower, TC
    Cherry, KJ
    Gloviczki, P
    [J]. ANNALS OF VASCULAR SURGERY, 2004, 18 (03) : 271 - 279
  • [9] Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Braegelmann, A.
    Bunck, A.
    Donas, K.
    Kasprzak, B.
    Maintz, D.
    Heindel, W.
    Seifarth, H.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (04): : 351 - 357
  • [10] Endoleaks during follow-up after endovascular repair of abdominal aortic aneurysm - Are they all dangerous?
    Buth, J
    Harris, PL
    Van Marrewijk, C
    Fransen, G
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 559 - 566