Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm

被引:66
|
作者
Elkouri, S
Panneton, JM
Andrews, JC
Lewis, BD
McKusick, MA
Noel, AA
Rowland, CM
Bower, TC
Cherry, KJ
Gloviczki, P
机构
[1] Mayo Clin & Mayo Fdn, Div Vasc Surg, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
关键词
D O I
10.1007/s10016-004-0034-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to compare our experience with duplex ultrasonography (US) and computed tomography (CT) for the routine follow-up of patients after endovascular repair (EVAR) of abdominal aortic aneurysm (AAA). We reviewed the electronic charts and radiologic exams of the first 125 patients (113 males, 12 females, median age of 76 years, range 48-98 years) with AAA treated by EVAR from June 1996 to November 2001. Our follow-up protocol included serial CT and US at regular intervals after the procedure (before discharge, at 1 month, and then every 6 months). Adequacy of each exam, ability to detect endoleaks, measurements of AAA diameter, and ability to determine graft patency were compared. For endoleak detection, comparison between CT and US was done using CT as the gold standard. A total of 608 exams, 337 CTs and 271 US, were performed 1 day to 5 years after endovascular aneurysm repair; 98% of CT and 74% of US were technically adequate. Contrary to CT, the proportion of adequate US exam was significantly less in patients with higher body mass index (BMIgreater than or equal to30=54% vs. BMI<30=81%, p<0.001) and for pre-discharge US compared to the post-discharge US (54% vs. 88%, p=0.0005). Concurrent scan pairs were obtained in 252 instances in 107 patients (1-8 pairs per patient). Excellent correlation between AAA diameter measured on CT and US was noted (correlation coefficient of 0.9, p<0.0001). However, agreement was poor. CT anteroposterior (AP) and transverse measurements were on average 2.9 mm (95% limits of agreement = -7 to 13 mm) and 1.8 mm (95% limits of agreement = -9 to 12 mm) greater than US. For AAA diameter change, there was no case of increase AP diameter on CT. However, in 23% (29/128 pairs of sets) of US, an increase in AAA size that could have influenced patient management (greater than or equal to4 mm) was reported despite no change demonstrated on CT. For endoleak detection, sensitivity and specificity of US compared to that of CT was 25% and 89%. Similar sensitivity and specificity were noted when we excluded the first set (25% and 95%), sets done prior to 2000 (30% and 89%), inadequate CT or US scans (31% and 98%), or duplicate sets of results for each patient (28% and 81%). Of the 27 endoleaks missed on US in 17 patients, 2 were type I endoleaks. None of the four endoleaks seen only on US were type I endoleak. US usefulness prior to discharge was reduced by the high rate of inadequate exam, especially in obese patients. Despite the excellent correlation in AAA diameter between US and CT, there was significant disagreement in AAA diameter measurement and diameter change. Sensitivity of nonstandardized US for endoleak was low compared to CT. CT remains our primary imaging study after EVAR, but standardization of post-EVAR US technique may improve its accuracy.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 50 条
  • [1] Clinical Utility and Safety of Noncontrast Computed Tomography for Follow-up After Endovascular Abdominal Aortic Aneurysm Repair
    Bobadilla, Joseph L.
    Suwanabol, Pasithorn
    Reeder, Scott
    Pozniak, Myron
    Tefera, Girma
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 51 : 28S - 29S
  • [2] Clinical Implications of Non-Contrast-Enhanced Computed Tomography for Follow-Up After Endovascular Abdominal Aortic Aneurysm Repair
    Bobadilla, Joseph Louis
    Suwanabol, Pasithorn A.
    Reeder, Scott B.
    Pozniak, Myron A.
    Bley, Thorsten A.
    Tefera, Girma
    [J]. ANNALS OF VASCULAR SURGERY, 2013, 27 (08) : 1042 - 1048
  • [3] Role of Contrast-Enhanced Ultrasound in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Benedetto, Filippo
    Spinelli, Domenico
    La Corte, Francesco
    Pipito, Narayana
    Passari, Gabriele
    De Caridi, Giovanni
    [J]. DIAGNOSTICS, 2022, 12 (12)
  • [4] Volumetric analysis by non contrast computed tomography is comparable to that of contrast enhanced computed tomography in the follow-up of patients with endovascular abdominal aortic aneurysm repair
    Nambi, Preethi
    Sengupta, Ranjila
    Muthupillai, Raja
    Strickman, Neil
    Krajcer, Zvonimir
    Cheong, Benjamin Y. C.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A353 - A353
  • [5] Follow up of endovascular abdominal aortic aneurysm repair with contrast ultrasound
    Deklunder, G.
    Sediri, I.
    Donati, T.
    Boivin, V.
    Gautier, C.
    Haulon, S.
    [J]. JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 141 - 147
  • [6] Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair
    Wever, JJ
    Blankensteijn, JD
    Mali, WPTM
    Eikelboom, BC
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 177 - 182
  • [7] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [8] Follow-up of aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Bravo Soberon, Alberto
    Marti de Garcia, Milagros
    Garzon Moll, Gonzalo
    Rodriguez Vigil, Beatriz
    Allona Krauel, Maria
    Alvarez-Sala Walter, Rodolfo
    [J]. ANNALS OF VASCULAR SURGERY, 2008, 22 (04) : 559 - 563
  • [9] Follow-Up Compliance After Endovascular Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P.
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 809 - 809
  • [10] Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair
    Spanos, Konstantinos
    Karathanos, Christos
    Athanasoulas, Athanasios
    Sapeltsis, Vasileios
    Giannoukas, Athanasios D.
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (04): : 611 - 618