Air-kerma to Hp(0.07), Hp(3), and Hp(10) conversion coefficients for monoenergetic photons

被引:7
|
作者
Al Kanti, Hassan [1 ]
El Hajjaji, O. [1 ]
El Bardouni, T. [1 ]
Boukhal, H. [1 ]
机构
[1] Abdelmalek Essaadi Univ, Fac Sci, Radiat & Nucl Syst Lab, Tetouan, Morocco
关键词
Conversion coefficients; Personal dose equivalent; Photons; MC; MONTE-CARLO; CYLINDER PHANTOM; ELECTRONS; ENERGY; EGSNRC;
D O I
10.1016/j.apradiso.2020.109123
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This work aims for calculating a new set of the personal dose equivalent conversion coefficients H-p(d)/K-air when d = 0.07, 3, and 10 mm, for monoenergetic photons beams ranged from 0.015 to 10 MeV, which have incident on ICRU slab phantom for H-p (0.07) and H-p (10) and cylindrical phantom for H-p (3). The new cylindrical phantom of the ORAMED project was proposed for calculating the eye lens dose equivalent as a cylinder much better approximates the form of a head than a slab. The calculations were carried out with MC and an analytical fit is applied to the data. Our results are found in a good agreement with those previously published, with a local difference less than 1.5%. We have concluded that new analytical fits provide a suitable method for determining conversion coefficients for discrete incident such as MC.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Monte Carlo simulation of the conversion coefficients for Hp(3) and Dp lens for diagnostic X-rays
    Teng Z.
    Song M.
    Wei K.
    Hang Z.
    Geng X.
    Gao F.
    Liu Y.
    Liu S.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2022, 43 (11): : 1604 - 1610
  • [32] THE PERSONAL-COMPUTER APPLICATION FOR HS(0.07) AND HP(10) MEASUREMENT IN THE NATIONAL PERSONNEL DOSIMETRY SERVICE IN CZECHOSLOVAKIA
    TROUSIL, J
    STRBA, J
    PLICHTA, J
    PRUSA, J
    HANAUER, K
    KERNENERGIE, 1991, 34 (03): : 94 - 97
  • [33] Bias-corrected Hp(10)-to-Organ-Absorbed Dose Conversion Coefficients for the Epidemiological Study of Korean Radiation Workers
    Jeong, Areum
    Kwon, Tae-Eun
    Lee, Wonho
    Park, Sunhoo
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2022, 47 (03): : 158 - 166
  • [34] The experimental study of R290 mass distribution and indoor leakage of 2 HP and 3 HP split type household air conditioner
    Tang, Weier
    He, Guogeng
    Zhou, Sai
    Sun, Wei
    Cai, Dehua
    Liu, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 246 - 254
  • [35] Evaluation of conversion coefficients relating air-kerma to H☆(10) using primary and transmitted x-ray spectra in the diagnostic radiology energy range
    Santos, J. C.
    Mariano, L.
    Tomal, A.
    Costa, P. R.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 117 - 132
  • [36] Evaluation of mean conversion coefficients from air-kerma to H*(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range
    Gonzales, A. H. Lopez
    Santos, J. C.
    Mariano, L.
    Tomal, A.
    Costa, P. R.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : 842 - 857
  • [37] AIR KERMATO HP(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICS
    Principi, S.
    Guardiola, C.
    Duch, M. A.
    Ginjaume, M.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 45 - 48
  • [38] MONTE CARLO DETERMINATION OF THE CONVERSION COEFFICIENTS HP(3)/Ka IN A RIGHT CYLINDER PHANTOM WITH 'PENELOPE' CODE. COMPARISON WITH 'MCNP' SIMULATIONS
    Daures, J.
    Gouriou, J.
    Bordy, J. M.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 37 - 42
  • [39] AIR KERMA TO DOSE EQUIVALENT CONVERSION COEFFICIENTS NOT INCLUDED IN ISO 4037-3
    Behrens, Rolf
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 373 - 379
  • [40] SYNTHESIS OF K4HP3O10.XH2O
    SHASHKOVA, IL
    VRUBLEVSKII, AV
    LYUTSKO, VA
    PRODAN, EA
    INORGANIC MATERIALS, 1991, 27 (01) : 63 - 67