The experimental study of R290 mass distribution and indoor leakage of 2 HP and 3 HP split type household air conditioner

被引:25
|
作者
Tang, Weier [1 ]
He, Guogeng [1 ]
Zhou, Sai [1 ]
Sun, Wei [1 ]
Cai, Dehua [1 ]
Liu, Feng [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Hubei, Peoples R China
[2] TCL Air Conditioner Zhongshan Co Ltd, Zhongshan 528427, Peoples R China
关键词
R290; Air conditioner; Mass distribution; Indoor leakage; Safety; QUANTITATIVE RISK-ASSESSMENT; DISPERSE REFRIGERANT RELEASES; HYDROCARBON REFRIGERANTS; FLAMMABILITY HAZARDS; EXPERIMENTAL PERFORMANCE; INSTALLATION FEATURES; EQUIPMENT DESIGN; ASSESSMENT MODEL; PART II; SAFETY;
D O I
10.1016/j.ijrefrig.2019.02.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
R290 is a promising future refrigerant, but its flammability presents the biggest obstacle to its adoption. This paper is concerned with the safety of a 2 HP and 3 HP split type household air conditioner (STHAC) with a 400 g, 450 g and 500 g charge of R290. Evaluation of the mass distribution of R290 in the indoor and outdoor units of the 2 HP and 3 HP STHAC was carried out and the R290 concentration distribution in a sealed room after a leakage under different scenarios was also examined. The results show that most of the refrigerant (72-80%) was located in the outdoor unit during the steady cooling mode. In the event of a leak indoors the combustible zone only appears underneath the leak position in the sealed room. The range and residence time of the combustible zone will increase with higher refrigerant charge quantity and negligible fire hazard appeared in the room if the leakage hole was 0.5 mm. In addition, the practical and achievable approach to significantly reduce the leaking rate and minimise the flammability hazard was found to be by installing a solenoid valve behind the capillary tube and is effective in both 2 HP and 3 HP STHAC. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 26 条
  • [1] R290 leakage hazards assessment of a 1 HP split-type household air conditioner by concentration detection and ignition experiment
    Ning, Qian
    He, Guogeng
    Sun, Wei
    Fan, Mingjing
    Li, Xiao
    Hong, Zhiwei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 139 : 70 - 83
  • [2] Assessment of leakage and risk reduction of R290 in a split type household air conditioner
    Tang, Weier
    He, Guogeng
    Sun, Wei
    Zhou, Sai
    Cai, Dehua
    Zhu, Yihao
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 89 : 70 - 82
  • [3] The experimental investigation of refrigerant distribution and leaking characteristics of R290 in split type household air conditioner
    Tang, Weier
    He, Guogeng
    Cai, Dehua
    Zhu, Yihao
    Zhang, Aoni
    Tian, Qiqi
    APPLIED THERMAL ENGINEERING, 2017, 115 : 72 - 80
  • [4] Measurement of refrigerant mass distribution within a R290 split air conditioner
    Li, Tingxun
    Lu, Jian
    Chen, Lei
    He, Dongcai
    Qiu, Xiaozhou
    Li, Hongyao
    Liu, Zhen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 57 : 163 - 172
  • [5] INVESTIGATION OF THE PRACTICAL METHOD FOR ENHANCING THE SAFETY OF R290 SPLIT TYPE HOUSEHOLD AIR CONDITIONER
    Tang, Weier
    He, Guogeng
    Cai, Dehua
    Zhu, Yihao
    Zhang, Aoni
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 514 - 521
  • [6] INVESTIGATION OF THE PRACTICAL METHOD FOR ENHANCING THE SAFETY OF R290 SPLIT TYPE HOUSEHOLD AIR CONDITIONER
    Tang, Weier
    He, Guogeng
    Cai, Dehua
    Zhu, Yihao
    Zhang, Aoni
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1169 - 1176
  • [7] A mathematical model of critical releasable charge for R290 indoor leakage of split-type household air conditioners
    Ning, Qian
    He, Guogeng
    Xiong, Jun
    Fan, Mingjing
    Li, Xiao
    BUILDING AND ENVIRONMENT, 2023, 228
  • [8] Experimental study of an R290 split-type air conditioner using a falling film condenser
    Ruan, Jiangao
    Liu, Jinping
    Xu, Xiongwen
    Chen, Jianxun
    Li, Guoli
    APPLIED THERMAL ENGINEERING, 2018, 140 : 325 - 333
  • [9] Experimental study of leakage safety of a novel integral-type air conditioner using R290
    Wu, Guoqiang
    Ma, Guoyuan
    Xu, Shuxue
    Jia, Xiaoya
    Liu, Shuailing
    Gong, Yuexuan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 296 - 304
  • [10] Performance and refrigerant mass distribution of a R290 split air conditioner with different lubricating oils
    Chen, Rui
    Wu, Jianhua
    Duan, Jvyuan
    APPLIED THERMAL ENGINEERING, 2019, 162