The experimental study of R290 mass distribution and indoor leakage of 2 HP and 3 HP split type household air conditioner

被引:25
|
作者
Tang, Weier [1 ]
He, Guogeng [1 ]
Zhou, Sai [1 ]
Sun, Wei [1 ]
Cai, Dehua [1 ]
Liu, Feng [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Hubei, Peoples R China
[2] TCL Air Conditioner Zhongshan Co Ltd, Zhongshan 528427, Peoples R China
关键词
R290; Air conditioner; Mass distribution; Indoor leakage; Safety; QUANTITATIVE RISK-ASSESSMENT; DISPERSE REFRIGERANT RELEASES; HYDROCARBON REFRIGERANTS; FLAMMABILITY HAZARDS; EXPERIMENTAL PERFORMANCE; INSTALLATION FEATURES; EQUIPMENT DESIGN; ASSESSMENT MODEL; PART II; SAFETY;
D O I
10.1016/j.ijrefrig.2019.02.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
R290 is a promising future refrigerant, but its flammability presents the biggest obstacle to its adoption. This paper is concerned with the safety of a 2 HP and 3 HP split type household air conditioner (STHAC) with a 400 g, 450 g and 500 g charge of R290. Evaluation of the mass distribution of R290 in the indoor and outdoor units of the 2 HP and 3 HP STHAC was carried out and the R290 concentration distribution in a sealed room after a leakage under different scenarios was also examined. The results show that most of the refrigerant (72-80%) was located in the outdoor unit during the steady cooling mode. In the event of a leak indoors the combustible zone only appears underneath the leak position in the sealed room. The range and residence time of the combustible zone will increase with higher refrigerant charge quantity and negligible fire hazard appeared in the room if the leakage hole was 0.5 mm. In addition, the practical and achievable approach to significantly reduce the leaking rate and minimise the flammability hazard was found to be by installing a solenoid valve behind the capillary tube and is effective in both 2 HP and 3 HP STHAC. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 26 条
  • [21] Experimental study on startup characteristics of a R290 room air conditioner under various ambient temperatures
    Wang, Che
    Wu, Jianhua
    Du, Yanjun
    Li, Jinbo
    Du, Wenqing
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 : 37 - 44
  • [22] Study on fault identification rules for real refrigerant leakage in R290 room air conditioner based random forest algorithm
    Yang, Jie
    Wu, Jianghong
    Yu, Xinyu
    Liang, Yongbiao
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238
  • [23] Experimental and numerical analysis of the performance of the R290 rotary compressor used in a split-room air conditioner at high ambient temperature
    Wu, Jian Hua
    Shi, Hong Yan
    Zhang, Shuai
    Li, Jia Chen
    Lei, Bo Wen
    Du, Yan Jun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 27 (02) : 226 - 239
  • [24] Oil retention and its mass distribution within a R290 room air conditioner using miscible or partially miscible oils
    Wu, Jianhua
    Chen, Zhenhua
    Chen, Rui
    Du, Yanjun
    Duan, Jvyuan
    Li, Xiaoyang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 111 : 20 - 28
  • [25] Experimental study on electronic expansion valve failure of a R290 room air conditioner during heating-defrosting process
    Du, Yanjun
    Wu, Jianhua
    Che Wang
    Li Jinbo
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [26] Experimental study on ventilation effect on concentration distribution of R32 leaking from floor type air conditioner
    Jin, Wufeng
    Gao, Pan
    Zheng, Yafei
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105