Air-kerma to Hp(0.07), Hp(3), and Hp(10) conversion coefficients for monoenergetic photons

被引:7
|
作者
Al Kanti, Hassan [1 ]
El Hajjaji, O. [1 ]
El Bardouni, T. [1 ]
Boukhal, H. [1 ]
机构
[1] Abdelmalek Essaadi Univ, Fac Sci, Radiat & Nucl Syst Lab, Tetouan, Morocco
关键词
Conversion coefficients; Personal dose equivalent; Photons; MC; MONTE-CARLO; CYLINDER PHANTOM; ELECTRONS; ENERGY; EGSNRC;
D O I
10.1016/j.apradiso.2020.109123
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This work aims for calculating a new set of the personal dose equivalent conversion coefficients H-p(d)/K-air when d = 0.07, 3, and 10 mm, for monoenergetic photons beams ranged from 0.015 to 10 MeV, which have incident on ICRU slab phantom for H-p (0.07) and H-p (10) and cylindrical phantom for H-p (3). The new cylindrical phantom of the ORAMED project was proposed for calculating the eye lens dose equivalent as a cylinder much better approximates the form of a head than a slab. The calculations were carried out with MC and an analytical fit is applied to the data. Our results are found in a good agreement with those previously published, with a local difference less than 1.5%. We have concluded that new analytical fits provide a suitable method for determining conversion coefficients for discrete incident such as MC.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Eye lens dosimetry in Canadian CANDU nuclear power plants based on operational dosimetric quantities Hp(10) and Hp(0.07)
    Atanackovic, J.
    Hanu, A. R.
    Byun, S. H.
    APPLIED RADIATION AND ISOTOPES, 2021, 177
  • [22] Fluence to Hp(3) conversion coefficients for neutrons from thermal to 15 MeV
    Gualdrini, G.
    Ferrari, P.
    Tanner, R.
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 278 - 290
  • [23] Comparing Hp(3) evaluated from the conversion coefficients from air kerma to personal dose equivalent for eye lens dosimetry calibrated on a new cylindrical PMMA phantom
    Esor, J.
    Sudchai, W.
    Monthonwattana, S.
    Pungkun, V.
    Intang, A.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016, 2017, 860
  • [24] Characterisation of a personal TL photon dosemeter based on two LiF(Mg,Cu,P) detectors in terms of Hp(0.07,α) and Hp(10,α)
    Fantuzzi, E
    Monteventi, F
    Sermenghi, I
    Uleri, G
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 179 - 182
  • [25] Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling
    Arectout, A.
    Zidouh, I
    Sadeq, Y.
    Azougagh, M.
    Maroufi, B.
    Chakir, E.
    Boukhal, H.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (01) : 301 - 309
  • [26] TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H) WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07)
    Pereira, J. S.
    Pereira, M. F.
    Rangel, S.
    Caldeira, M.
    Carvalhal, G.
    Santos, L. M.
    Cardoso, J. V.
    Alves, J. G.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 216 - 223
  • [27] Development of a badge for the thin-layer thermoluminescence dosemeter system TL-DOS to measure the personal dose equivalent Hp(10) and Hp(0.07)
    Piepenbrock, M.
    Busch, F.
    Henniger, J.
    Kroeninger, K.
    Walbersloh, J.
    RADIATION MEASUREMENTS, 2017, 106 : 543 - 545
  • [28] Conversion coefficients from fluence and air kerma to personal dose equivalent for monoenergetic photons using analytical fit and Monte Carlo simulation
    Al Kanti, Hassan
    El Hajjaji, O.
    El Bardouni, T.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (01): : 31 - 44
  • [29] MEASUREMENT OF OPERATIONAL QUANTITIES HP(0.07) AND HP(3) FOR INDIGENOUSLY DEVELOPED 106Ru/106Rh SOURCE USING AN EXTRAPOLATION CHAMBER
    Vandana, S.
    Bakshi, A. K.
    Behrens, R.
    Chattaraj, A.
    Saxena, S. K.
    Dhami, P. S.
    Panja, S.
    Jagasia, P.
    Selvam, T. Palani
    Dash, A.
    Datta, D.
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (03) : 376 - 386
  • [30] HP(3)/Φ CONVERSION COEFFICIENTS FOR NEUTRONS: DISCUSSION ON THE BASIS OF THE NEW ICRP RECOMMENDED LIMIT FOR THE EYE LENS
    Ferrari, P.
    Gualdrini, G.
    Tanner, R.
    Fantuzzi, E.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 17 - 22