Eye lens dosimetry in Canadian CANDU nuclear power plants based on operational dosimetric quantities Hp(10) and Hp(0.07)

被引:3
|
作者
Atanackovic, J. [1 ,3 ]
Hanu, A. R. [2 ,3 ]
Byun, S. H. [3 ]
机构
[1] Ontario Power Generat, Whitby, ON L1N 9E3, Canada
[2] Bruce Power, Tiverton, ON N0G 2T0, Canada
[3] McMaster Univ, Dept Phys & Astron, Hamilton, ON L8S 4L8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Eye lens dosimetry; CANDU power plants; Beta and gamma spectral measurements at; H-p(10) and H-p(0.07); Protection dosimetric quantities; Operational dosimetric quantities; CONVERSION COEFFICIENTS;
D O I
10.1016/j.apradiso.2021.109902
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this article, we present a methodology for performing eye lens dosimetry in CANDU nuclear power plants using an existing and highly accurate Harshaw 4-element TLD-700 dosemeter. This dosemeter, which has been specially designed for Ontario Power Generation (OPG) and Bruce Power (BP), measures the deep and shallow personal dose equivalent quantities H-p(10) and H-p(0.07), respectively. Using these measured personal dose equivalent quantities and applying a beta-ray strength scaling factor to the H-p(0.07) measurement in particular, we have developed an algorithm that can be used to calculate the dose to the lens of the eye in mixed beta-gamma fields. This scaling factor has been developed and is primarily based on results obtained from extensive collaborative study, performed by Ontario Power Generation (OPG), Bruce Power (BP) and McMaster University, through Candu Owners Group (COG) support (Bohra et al., 2021; Laranjeiro et al., 2020). Furthermore, scaling factor F, also includes effects of protective glass eyewear and results from Whole body dosimetry intercomparison exercises. The algorithm to calculate eye lens dose at CANDU power plants has been developed, based on this scaling factor and operational dosimetric quantities H-p(10) and H-p(0.07)
引用
收藏
页数:5
相关论文
共 6 条
  • [1] On the operational quantity Hp(3) for eye lens dosimetry
    Behrens, R.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (04) : 455 - 464
  • [2] A new personal dosimetry system for Hp(10) and Hp(0.07) photon dose based on OSL-dosimetry of beryllium oxide
    Sommer, M.
    Jahn, A.
    Henniger, J.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1818 - 1821
  • [3] Hp(0.07) PHOTON DOSEMETERS FOR EYE LENS DOSIMETRY: CALIBRATION ON A ROD Vs. A SLAB PHANTOM
    Behrens, R.
    Engelhardt, J.
    Figel, M.
    Hupe, O.
    Jordan, M.
    Seifert, R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 139 - 142
  • [4] Relationship between protection and operational quantities in dosimetry of photon external exposure -: Deficiencies of Hp(10)
    Chumak, VV
    Bakhanova, EV
    [J]. RADIATION PROTECTION DOSIMETRY, 2003, 104 (02) : 103 - 111
  • [5] CHARACTERIZATION OF A LANTHANUM BROMIDE DETECTOR FOR EYE LENS DOSIMETRY AT THE CANDU NUCLEAR POWER PLANTS BASED ON DIRECT MEASUREMENTS OF THE GAMMA-RAY SPECTRA
    Laranjeiro, A. S.
    Bohra, F.
    Byun, S. H.
    Atanackovic, J.
    Hanu, A. R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 309 - 320
  • [6] Quantification of pure beta spectra in mixed beta gamma fields as part of eye lens dosimetry at CANDU power plants
    Bohra, F.
    Atanackovic, J.
    Byun, S. H.
    Hanu, A. R.
    Laranjeiro, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 174 (174)