Evaluation of spatial resolution in image acquisition by optical flatbed scanners for radiochromic film dosimetry

被引:7
|
作者
Asero, G. [1 ,2 ]
Greco, C. [3 ,4 ]
Gueli, A. M. [1 ,2 ,4 ]
Raffaele, L. [3 ,4 ]
Spampinato, S. [1 ,2 ,4 ]
机构
[1] Univ Catania, Dipartimento Fis & Astron, PH3DRA Labs PHys Dating Diagnost Dosimetry Res &, Via Santa Sofia 64, I-95123 Catania, Italy
[2] Ist Nazl Fis Nucl, Via Santa Sofia 64, I-95123 Catania, Italy
[3] Azienda Osped Univ Policlin Vittorio Emanuele, Via Santa Sofia 78, I-95123 Catania, Italy
[4] Univ Catania, Scuola Fac Med, Dipartimento Sci Med Chirurg & Tecnol Avanzate GF, Scuola Specializzaz Fis Med, Via Santa Sofia 78, I-95123 Catania, Italy
来源
关键词
Image reconstruction in medical imaging; Data processing methods; Dosimetry concepts and apparatus; X-ray radiography and digital radiography (DR); XR TYPE-T; ENERGY RESPONSE;
D O I
10.1088/1748-0221/11/03/P03024
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Introduction: Radiochromic films are two-dimensional dosimeters that do not require developing and give values of absorbed dose with accuracy and precision. Since this dosimeter colours directly after irradiation, it can be digitized with commercial optical flatbed scanners to obtain a calibration curve that links blackening of the film with dose. Although the film has an intrinsic high spatial resolution, the scanner determines the actual resolution of this dosimeter, in particular the "dot per inch" (dpi) parameter. The present study investigates the effective spatial resolution of a scanner used for Gafchromic (R) XR-QA2 film (designed for radiology Quality Assurance) analysis. Material and methods: The quantitative evaluation of the resolution was performed with the Modulation Transfer Function (MTF) method, comparing the nominal resolution with the experimental one. The analysis was performed with two procedures. First, the 1951 USAF resolution test chart, a tool that tests the performance of optical devices, was used. Secondly, a combined system of mammography X-ray tube, XR-QA2 film and a bar pattern object was used. In both cases the MTF method has been applied and the results were compared. Results: The USAF and the film images have been acquired with increasing dpi and a standard protocol for radiochromic analysis, to evaluate horizontal and vertical and resolution. The effective resolution corresponds to the value of the MTF at 50%. In both cases and for both procedures, it was verified that, starting from a dpi value, the effective resolution saturates. Conclusion: The study found that, for dosimetric applications, the dpi of the scanner have to be adjusted to a reasonable value because, if too high, it requires high scanning and computational time without providing additional information.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Effect of mirror system and scanner bed of a flatbed scanner on lateral response artefact in radiochromic film dosimetry
    Shameem, Tarafder
    Bennie, Nick
    Butson, Martin
    Thwaites, David
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1651 - 1663
  • [32] High sensitivity radiochromic film dosimetry using an optical common-mode rejection and a reflective-mode flatbed color scanner
    Ohuchi, Hiroko
    MEDICAL PHYSICS, 2007, 34 (11) : 4207 - 4212
  • [33] Evaluation of Sensitivity and Uniformity of New Radiochromic Film with Two Commercial Scanners
    Kamomae, T.
    Miyabe, Y.
    Sawada, A.
    Oita, M.
    Fujimoto, T.
    Yano, S.
    Nakata, M.
    Nakayama, S.
    Hiraoka, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3727 - 3727
  • [34] High-resolution dosimetry using radiochromic film and a document scanner
    Stevens, MA
    Turner, JR
    Hugtenburg, RP
    Butler, PH
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11): : 2357 - 2365
  • [35] Comparison of three high-resolution digitizers for radiochromic film dosimetry
    Gluckman, GR
    Reinstein, LE
    MEDICAL PHYSICS, 2002, 29 (08) : 1839 - 1846
  • [36] Gafchromic film dosimetry: Four years experience using FilmQA Pro software and Epson flatbed scanners
    Mathot, M.
    Sobczak, S.
    Hoornaert, M. -T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 871 - 877
  • [37] Evaluation of a single-scan protocol for radiochromic film dosimetry
    Shimohigashi, Yoshinobu
    Araki, Fujio
    Maruyama, Masato
    Nakaguchi, Yuji
    Kuwahara, Satoshi
    Nagasue, Nozomu
    Kai, Yudai
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 412 - 424
  • [38] Efficient Method for Combining Flatbed Scanner Calibration and Lateral Response Correction in a Single Scan for Radiochromic Film Dosimetry
    Ren, T.
    Bourland, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E607 - E607
  • [39] The influence of scanner parameters on the accuracy of film dosimetry: A comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners
    Wilcox, E.
    Daskalov, G.
    Nedialkova, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2496 - 2496
  • [40] Does mechanical pressure on radiochromic film affect optical absorption and dosimetry?
    Yu P.K.N.
    Butson M.
    Cheung T.
    Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (3): : 285 - 287