首页
学术期刊
论文检测
AIGC检测
热点
更多
数据
Efficient Method for Combining Flatbed Scanner Calibration and Lateral Response Correction in a Single Scan for Radiochromic Film Dosimetry
被引:0
|
作者
:
Ren, T.
论文数:
0
引用数:
0
h-index:
0
机构:
Wake Forest Sch Med, Winston Salem, NC USA
Wake Forest Univ, Winston Salem, NC 27109 USA
Wake Forest Sch Med, Winston Salem, NC USA
Ren, T.
[
1
,
2
]
Bourland, J.
论文数:
0
引用数:
0
h-index:
0
机构:
Wake Forest Sch Med, Winston Salem, NC USA
Wake Forest Univ, Winston Salem, NC 27109 USA
Wake Forest Sch Med, Winston Salem, NC USA
Bourland, J.
[
1
,
2
]
机构
:
[1]
Wake Forest Sch Med, Winston Salem, NC USA
[2]
Wake Forest Univ, Winston Salem, NC 27109 USA
来源
:
MEDICAL PHYSICS
|
2018年
/ 45卷
/ 06期
关键词
:
D O I
:
暂无
中图分类号
:
R8 [特种医学];
R445 [影像诊断学];
学科分类号
:
1002 ;
100207 ;
1009 ;
摘要
:
WE-C1000-G
引用
收藏
页码:E607 / E607
页数:1
相关论文
共 47 条
[1]
An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan
Lewis, David
论文数:
0
引用数:
0
h-index:
0
机构:
Ashland Inc, Adv Mat Grp, Wayne, NJ 07470 USA
Mem Sloan Kettering Canc Ctr, Dept Med Phys, Basking Ridge, NJ 07920 USA
Lewis, David
Micke, Andre
论文数:
0
引用数:
0
h-index:
0
机构:
Ashland Inc, Adv Mat Grp, Wayne, NJ 07470 USA
Mem Sloan Kettering Canc Ctr, Dept Med Phys, Basking Ridge, NJ 07920 USA
Micke, Andre
Yu, Xiang
论文数:
0
引用数:
0
h-index:
0
机构:
Ashland Inc, Adv Mat Grp, Wayne, NJ 07470 USA
Mem Sloan Kettering Canc Ctr, Dept Med Phys, Basking Ridge, NJ 07920 USA
Yu, Xiang
Chan, Maria F.
论文数:
0
引用数:
0
h-index:
0
机构:
Mem Sloan Kettering Canc Ctr, Dept Med Phys, Basking Ridge, NJ 07920 USA
Mem Sloan Kettering Canc Ctr, Dept Med Phys, Basking Ridge, NJ 07920 USA
Chan, Maria F.
MEDICAL PHYSICS,
2012,
39
(10)
: 6339
-
6350
[2]
Effect of mirror system and scanner bed of a flatbed scanner on lateral response artefact in radiochromic film dosimetry
Shameem, Tarafder
论文数:
0
引用数:
0
h-index:
0
机构:
North Coast Canc Inst, Lismore, NSW, Australia
Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
North Coast Canc Inst, Lismore, NSW, Australia
Shameem, Tarafder
Bennie, Nick
论文数:
0
引用数:
0
h-index:
0
机构:
North Coast Canc Inst, Lismore, NSW, Australia
North Coast Canc Inst, Lismore, NSW, Australia
Bennie, Nick
Butson, Martin
论文数:
0
引用数:
0
h-index:
0
机构:
Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
EPA, Sydney, NSW, Australia
North Coast Canc Inst, Lismore, NSW, Australia
Butson, Martin
Thwaites, David
论文数:
0
引用数:
0
h-index:
0
机构:
Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
North Coast Canc Inst, Lismore, NSW, Australia
Thwaites, David
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE,
2024,
47
(04)
: 1651
-
1663
[3]
Flatbed scanner stability for radiochromic film dosimetry
Laosa, C.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Laosa, C.
Calvo Ortega, J. F.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Calvo Ortega, J. F.
Moragues Femenia, S.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Moragues Femenia, S.
Casals, J.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Hosp Quironsalud, Radioterapia, Barcelona 08035, Spain
Casals, J.
RADIOTHERAPY AND ONCOLOGY,
2019,
133
: S910
-
S910
[4]
Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure
Menegotti, L.
论文数:
0
引用数:
0
h-index:
0
机构:
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Menegotti, L.
Delana, A.
论文数:
0
引用数:
0
h-index:
0
机构:
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Delana, A.
Martignano, A.
论文数:
0
引用数:
0
h-index:
0
机构:
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Sch Med Phys, Padua, Italy
Santa Chiara Hosp, Dept Med Phys, APSS Trento, Italy
Martignano, A.
MEDICAL PHYSICS,
2008,
35
(07)
: 3078
-
3085
[5]
RADIOCHROMIC FILM DOSIMETRY WITH FLATBED SCANNERS: A FAST AND ACCURATE METHOD FOR DOSE CALIBRATION AND UNIFORMITY CORRECTION WITH SINGLE FILM EXPOSURE
Menegotti, L.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp S Chiara, Med Phys, Trento, Italy
Hosp S Chiara, Med Phys, Trento, Italy
Menegotti, L.
Delana, A.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp S Chiara, Med Phys, Trento, Italy
Hosp S Chiara, Med Phys, Trento, Italy
Delana, A.
Vanoni, V.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp S Chiara, Radiotherapy, Trento, Italy
Hosp S Chiara, Med Phys, Trento, Italy
Vanoni, V.
Martignano, A.
论文数:
0
引用数:
0
h-index:
0
机构:
Hosp S Chiara, Med Phys, Trento, Italy
Hosp S Chiara, Med Phys, Trento, Italy
Martignano, A.
RADIOTHERAPY AND ONCOLOGY,
2008,
88
: S391
-
S391
[6]
Development of a User-Friendly Correction Method for the Lateral Response Artifact From Flatbed Scanners in Radiochromic Film Dosimetry
Guyer, G.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Guyer, G.
Kueng, R.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Kueng, R.
Joosten, A.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Joosten, A.
Fix, M. K.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Fix, M. K.
Manser, P.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Manser, P.
Mueller, S.
论文数:
0
引用数:
0
h-index:
0
机构:
Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
Mueller, S.
MEDICAL PHYSICS,
2021,
48
(06)
[7]
Correction of lateral response artifacts from flatbed scanners for dual-channel radiochromic film dosimetry
Akino, Yuichi
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Akino, Yuichi
Shiomi, Hiroya
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Shiomi, Hiroya
Isohashi, Fumiaki
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Isohashi, Fumiaki
Suzuki, Osamu
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Heavy Ion Therapy Ctr, Osaka 5400008, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Suzuki, Osamu
Seo, Yuji
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Seo, Yuji
Tamari, Keisuke
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Tamari, Keisuke
Hirata, Takero
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Hirata, Takero
Mizuno, Hirokazu
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Rousai Hosp, Sakai, Osaka 5918025, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Mizuno, Hirokazu
Ogawa, Kazuhiko
论文数:
0
引用数:
0
h-index:
0
机构:
Osaka Univ, Grad Sch Meidcine, Suita, Osaka 5650871, Japan
Osaka Univ Hosp, Oncol Ctr, 2-2 D10, Suita, Osaka 5650871, Japan
Ogawa, Kazuhiko
JOURNAL OF RADIATION RESEARCH,
2021,
62
(02)
: 319
-
328
[8]
Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry
Lewis, David
论文数:
0
引用数:
0
h-index:
0
机构:
RCF Consulting LLC, Monroe, CT 06468 USA
RCF Consulting LLC, Monroe, CT 06468 USA
Lewis, David
Chan, Maria F.
论文数:
0
引用数:
0
h-index:
0
机构:
Mem Sloan Kettering Canc Ctr, Basking Ridge, NJ 07920 USA
RCF Consulting LLC, Monroe, CT 06468 USA
Chan, Maria F.
MEDICAL PHYSICS,
2015,
42
(01)
: 416
-
429
[9]
A Simple Method for Quantifying and Reducing Lateral Response Artifact of Flatbed Scanner for Film Dosimetry
Du, X.
论文数:
0
引用数:
0
h-index:
0
机构:
Northwest Med Phys Ctr, Seattle, WA USA
Northwest Med Phys Ctr, Seattle, WA USA
Du, X.
Rasmussen, B.
论文数:
0
引用数:
0
h-index:
0
机构:
Marquette Gen Hosp, Marquette, MI USA
Northwest Med Phys Ctr, Seattle, WA USA
Rasmussen, B.
MEDICAL PHYSICS,
2021,
48
(06)
[10]
Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry
Paelinck, L.
论文数:
0
引用数:
0
h-index:
0
机构:
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
Paelinck, L.
De Neve, W.
论文数:
0
引用数:
0
h-index:
0
机构:
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
De Neve, W.
DeWagter, C.
论文数:
0
引用数:
0
h-index:
0
机构:
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
DeWagter, C.
PHYSICS IN MEDICINE AND BIOLOGY,
2007,
52
(01):
: 231
-
242
←
1
2
3
4
5
→