Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking

被引:236
|
作者
Keall, PJ
Joshi, S
Vedam, SS
Siebers, JV
Kini, VR
Mohan, R
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC 27514 USA
[3] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[4] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
4D radiotherapy; deformable image registration; treatment planning;
D O I
10.1118/1.1879152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. Temporal anatomic changes can occur for many reasons, though the focus of the current investigation is respiration motion for lung tumors. The aim of this study was to develop 4D radiotherapy treatment-planning methodology for DMLC-based respiratory motion tracking. A 4D computed tomography (CT) scan consisting of a series of eight 3D CT image sets acquired at different respiratory phases was used for treatment planning. Deformable image registration was performed to map each CT set from the peak-inhale respiration phase to the CT image sets corresponding to subsequent respiration phases. Deformable registration allows the contours defined on the peak-inhale CT to be automatically transferred to the other respiratory phase CT image sets. Treatment planning was simultaneously performed on each of the eight 3D image sets via automated scripts in which the MLC-defined beam aperture conforms to the PTV (which in this case equaled the GTV due to CT scan length limitations) plus a penumbral margin at each respiratory phase. The dose distribution from each respiratory phase CT image set was mapped back to the peak-inhale CT image set for analysis. The treatment intent of 4D planning is that the radiation beam defined by the DMLC tracks the respiration-induced target motion based on a feedback loop including the respiration signal to a real-time MLC controller. Deformation with respiration was observed for the lung tumor and normal tissues. This deformation was verified by examining the mapping of high contrast objects, such as the lungs and cord, between image sets. For the test case, dosimetric reductions for the cord, heart, and lungs were found for 4D planning compared with 3D planning. 4D radiotherapy planning for DMLC-based respiratory motion tracking is feasible and may offer tumor dose escalation and/or a reduction in treatment-related complications. However, 4D planning requires new planning tools, such as deformable registration and automated treatment planning on multiple CT image sets. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 50 条
  • [21] Four-dimensional treatment planning strategies for dynamic tumor tracking
    Carpentier, Emilie E.
    McDermott, Ronan L.
    Camborde, Marie-Laure A.
    Karan, Tania
    Bergman, Alanah M.
    Mestrovic, Ante
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [22] Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
    Rietzel, E
    Chen, GTY
    Choi, NC
    Willet, CG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1535 - 1550
  • [23] Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    Shirato, H
    Shimizu, S
    Kitamura, K
    Nishioka, T
    Kagei, K
    Hashimoto, S
    Aoyama, H
    Kunieda, T
    Shinohara, N
    Dosaka-Akita, H
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 435 - 442
  • [24] Quantification of motion of different thoracic locations using four-dimensional computed tomography: Implications for radiotherapy planning
    Maxim, Peter G.
    Loo, Billy W., Jr.
    Shirazi, Haider
    Thorndyke, Brian
    Luxton, Gary
    Le, Quynh-Thu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (05): : 1395 - 1401
  • [25] IMPLICATIONS OF RESPIRATORY MOTION AS MEASURED BY FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY FOR RADIATION TREATMENT PLANNING OF ESOPHAGEAL CANCER
    Patel, Abhijit A.
    Wolfgang, John A.
    Niemierko, Andrzej
    Hong, Theodore S.
    Yock, Torunn
    Choi, Noah C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 290 - 296
  • [26] Real-time tumor-tracking and four-dimensional radiotherapy
    Shirato, H. (shirato@med.hokudai.ac.jp), 1600, Institute of Electronics Information and Communication Eng., Annex 3F, 5-22, Shibakoen 3 chome, Minato-ku, Tokyo, 105-0011, Japan (96):
  • [27] Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning
    Mori, Shinichiro
    Endo, Masahiro
    Asakura, Hiroshi
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : 5231 - 5244
  • [28] EFFECTIVE DOSES IN FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY FOR LUNG RADIOTHERAPY PLANNING
    Mori, Shinichiro
    Ko, Susumu
    Ishii, Takayosfii
    Nishizawa, Kanae
    MEDICAL DOSIMETRY, 2009, 34 (01) : 87 - 90
  • [29] An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapy
    Shankar Siva
    Daniel Pham
    Suki Gill
    Mathias Bressel
    Kim Dang
    Thomas Devereux
    Tomas Kron
    Farshad Foroudi
    Radiation Oncology, 8
  • [30] A novel four-dimensional radiotherapy planning strategy from a tumor-tracking beam's eye view
    Li, Guang
    Cohen, Patrice
    Xie, Huchen
    Low, Daniel
    Li, Diana
    Rimner, Andreas
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : 7579 - 7598