Four-dimensional treatment planning strategies for dynamic tumor tracking

被引:0
|
作者
Carpentier, Emilie E. [1 ,2 ,4 ]
McDermott, Ronan L. [3 ]
Camborde, Marie-Laure A. [2 ]
Karan, Tania [2 ]
Bergman, Alanah M. [2 ]
Mestrovic, Ante [2 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, 600 W 10th Ave, Vancouver, BC, Canada
[2] BC Canc, Dept Med Phys, Vancouver, BC, Canada
[3] BC Canc Vancouver, Radiat Oncol, Vancouver, BC, Canada
[4] BC Canc Vancouver, Med Phys, 600 W 10th Ave, Vancouver, BC, Canada
来源
关键词
4D dose calculation; 4D treatment planning; dynamic tumor tracking; gimballed linac system; GUIDED RADIOTHERAPY SYSTEM; MOTION; MANAGEMENT;
D O I
10.1002/acm2.14269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionDynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the "Boolean OAR Method" and the "Aperture Sorting Method," to determine if they can successfully spare an OAR while maintaining sufficient target coverage.Materials and methodsA step-and-shoot intensity modulated radiation therapy (sIMRT) treatment plan was re-optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the "Boolean OAR Method" created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the "Aperture Sorting Method" assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose.ResultsAll 10 OARs exceeded their dose constraints on the original plan four-dimensional (4D) dose distributions and average target coverage was V100% = 91.3% +/- 2.9% (ranging from 85.1% to 94.8%). The "Boolean OAR Method" spared 7/10 OARs, and mean target coverage decreased to V100% = 87.1% +/- 3.8% (ranging from 80.7% to 93.7%). The "Aperture Sorting Method" spared 9/10 OARs and the mean target coverage remained high at V100% = 91.7% +/- 2.8% (ranging from 84.9% to 94.5%).Conclusions4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The "Boolean OAR Method" improved sparing of OARs but target coverage was reduced. The "Aperture Sorting Method" further improved sparing of OARs and maintained target coverage.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    Shirato, H
    Shimizu, S
    Kitamura, K
    Nishioka, T
    Kagei, K
    Hashimoto, S
    Aoyama, H
    Kunieda, T
    Shinohara, N
    Dosaka-Akita, H
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 435 - 442
  • [2] A four-dimensional dynamic conformal arc approach for real-time tumor tracking: A retrospective treatment planning study
    Yau, Timothy
    Kempe, Jeff
    Gaede, Stewart
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [3] Planning Four-Dimensional Intensity-Modulated Arc Therapy for Tumor Tracking
    Niu, Y.
    Betzel, G.
    Yang, X.
    Gui, M.
    Parke, W.
    Yi, B.
    Yu, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] A four-dimensional dynamic conformal arc approach for real-time tumour tracking: a treatment planning study
    Yau, Timothy
    Gaede, Stewart
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5694 - 5694
  • [5] Respiratory gated and four-dimensional tumor tracking radiotherapy
    Keall, P.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2227 - 2228
  • [6] Respiratory gated and four-dimensional tumor tracking radiotherapy
    Keall, P
    [J]. LUNG CANCER, 2005, 49 : S56 - S56
  • [7] Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm
    Suh, Yelin
    Sawant, Amit
    Venkat, Raghu
    Keall, Paul J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12): : 3821 - 3835
  • [8] Weighted Four-Dimensional IMRT Planning for Dynamic MLC Tracking Using a Practical and Simple Framework
    Tachibana, H.
    Cheung, Y.
    Jain, S.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3833 - 3833
  • [9] FOUR-DIMENSIONAL INTENSITY-MODULATED RADIOTHERAPY PLANNING FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING RADIOTHERAPY
    Liang, Yueqiang
    Xu, Hongbing
    Yao, Jonathan
    Li, Zhihui
    Chen, Wendy
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 266 - 274
  • [10] A four-dimensional controller for DMLC-based tumor tracking
    Keall, PJ
    Wijesooriya, K
    Vedam, S
    George, R
    Todor, D
    Murphy, M
    Siebers, J
    Williamson, J
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S338 - S339