Four-dimensional treatment planning strategies for dynamic tumor tracking

被引:0
|
作者
Carpentier, Emilie E. [1 ,2 ,4 ]
McDermott, Ronan L. [3 ]
Camborde, Marie-Laure A. [2 ]
Karan, Tania [2 ]
Bergman, Alanah M. [2 ]
Mestrovic, Ante [2 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, 600 W 10th Ave, Vancouver, BC, Canada
[2] BC Canc, Dept Med Phys, Vancouver, BC, Canada
[3] BC Canc Vancouver, Radiat Oncol, Vancouver, BC, Canada
[4] BC Canc Vancouver, Med Phys, 600 W 10th Ave, Vancouver, BC, Canada
来源
关键词
4D dose calculation; 4D treatment planning; dynamic tumor tracking; gimballed linac system; GUIDED RADIOTHERAPY SYSTEM; MOTION; MANAGEMENT;
D O I
10.1002/acm2.14269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionDynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the "Boolean OAR Method" and the "Aperture Sorting Method," to determine if they can successfully spare an OAR while maintaining sufficient target coverage.Materials and methodsA step-and-shoot intensity modulated radiation therapy (sIMRT) treatment plan was re-optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the "Boolean OAR Method" created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the "Aperture Sorting Method" assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose.ResultsAll 10 OARs exceeded their dose constraints on the original plan four-dimensional (4D) dose distributions and average target coverage was V100% = 91.3% +/- 2.9% (ranging from 85.1% to 94.8%). The "Boolean OAR Method" spared 7/10 OARs, and mean target coverage decreased to V100% = 87.1% +/- 3.8% (ranging from 80.7% to 93.7%). The "Aperture Sorting Method" spared 9/10 OARs and the mean target coverage remained high at V100% = 91.7% +/- 2.8% (ranging from 84.9% to 94.5%).Conclusions4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The "Boolean OAR Method" improved sparing of OARs but target coverage was reduced. The "Aperture Sorting Method" further improved sparing of OARs and maintained target coverage.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Four-Dimensional Computer Tomography Scans for Conformal Thoracic Treatment Planning: Is a Single Scan Sufficient to Capture Thoracic Tumor Motion?
    Tseng, Y. D.
    Rengan, R.
    Apisarnthanarax, S.
    Zeng, J.
    Kim, E. Y.
    Patel, S. A.
    Wong, T. P.
    Bloch, C.
    Sandison, G. A.
    St James, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E426 - E426
  • [42] Four-Dimensional Speckle Tracking Echocardiography in Patients with Hypertrophic Cardiomyopathy
    Kilickesmez, Kadriye Orta
    Baydar, Onur
    Bostan, Cem
    Coskun, Ugur
    Kucukoglu, Serdar
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (10): : 1547 - 1553
  • [43] Tracking control and synchronization of four-dimensional hyperchaotic Rossler system
    Wang, Xing-Yuan
    Wu, Xiang-Jun
    [J]. CHAOS, 2006, 16 (03)
  • [44] PLANNING STUDY COMPARISON OF REAL-TIME TARGET TRACKING AND FOUR-DIMENSIONAL INVERSE PLANNING FOR MANAGING PATIENT RESPIRATORY MOTION
    Zhang, Peng
    Hugo, Geoffrey D.
    Yan, Di
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1221 - 1227
  • [45] Dynamic Four-Dimensional MR Angiography of the Chest and Abdomen
    Griffin, Michael
    Grist, Thomas M.
    Francois, Christopher J.
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (01) : 77 - +
  • [46] On the Dynamics of Immune-Tumor Conjugates in a Four-Dimensional Tumor Model
    Starkov, Konstantin E.
    Krishchenko, Alexander P.
    [J]. MATHEMATICS, 2024, 12 (06)
  • [47] The Technical Limitations of a Four-dimensional CT System for Radiotherapy Planning
    Smith, D. W.
    Dean, C. J.
    Lilley, J.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 250 - 251
  • [48] Inverse Planning for Four-dimensional Volumetric Modulated ARC Therapy
    Ma, Y.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S766 - S766
  • [49] Changes in chest wall thickness during four-dimensional CT in particle lung treatment planning
    Mori, S.
    Yamamoto, N.
    Nakajima, M.
    Baba, M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1004): : E158 - E160
  • [50] Color intensity projections: A rapid approach for evaluating four-dimensional CT scans in treatment planning
    Cover, KS
    Lagerwaard, FJ
    Senan, S