Four-Dimensional CT Analysis of Normal Syndesmotic Motion

被引:10
|
作者
Wong, Murray T. [1 ]
Wiens, Charmaine [1 ]
Lamothe, Jeremy [1 ]
Edwards, W. Brent [1 ]
Schneider, Prism S. [1 ]
机构
[1] Univ Calgary, Calgary, AB, Canada
关键词
4DCT; dynamic CT; syndesmosis; reduction; kinematics; DISTAL TIBIOFIBULAR SYNDESMOSIS; COMPUTED-TOMOGRAPHY; CLINICAL IMPORTANCE; ANKLE SYNDESMOSIS; SCREW FIXATION; SUTURE-BUTTON; REDUCTION; MALREDUCTION; INJURIES; BIOMECHANICS;
D O I
10.1177/10711007211015204
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The syndesmosis ligament complex stabilizes the distal tibiofibular joint while allowing for small amounts of physiologic motion. When injured, malreduction of the syndesmosis is the most important factor that contributes to inferior functional outcomes. Syndesmotic reduction is a dynamic measure, which is not adequately captured by conventional computed tomography (CT). Four-dimensional CT (4DCT) can image joints as they move through range of motion (ROM). The aim of this study was to employ 4DCT to determine in vivo syndesmotic motion with ankle ROM in uninjured ankles. Methods: Uninjured ankles were analyzed in patients who had contralateral syndesmotic injuries, as well as a cohort of healthy volunteers with bilateral uninjured ankles. Bilateral ankle 4DCT scans were performed as participants moved their ankles between maximal dorsiflexion and plantarflexion. Multiple measures of syndesmotic width, as well as sagittal translation and fibular rotation, were automatically extracted from 4DCT using a custom program to determine the change in syndesmotic position with ankle ROM. Results: Fifty-eight ankles were analyzed. Measures of syndesmotic width decreased by 0.7 to 1.1 mm as the ankle moved from dorsiflexion to plantarflexion (P < .001 for each measure). The fibula externally rotated by 1.2 degrees with ankle ROM (P < .001), but there was no significant motion in the sagittal plane (P = .43). No participants with bilateral uninjured ankles had a side-to-side difference in syndesmotic width of 2 mm or greater. Conclusion: 4DCT allows accurate, in vivo syndesmotic measurements, which change with ankle ROM, confirming prior work that was limited to biomechanical studies. Side-to-side syndesmotic measurements are consistent within subjects, validating the method of templating syndesmotic reduction off the contralateral ankle, in a consistent ankle position, to achieve anatomic reduction of syndesmotic injury.
引用
收藏
页码:1491 / 1501
页数:11
相关论文
共 50 条
  • [31] Four-dimensional non-rigid cardiac motion estimation
    Tang, Qiulin
    Cammin, Jochen
    Srivastava, Somesh
    Taguchi, Katsuyuki
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [32] Repeatability Analysis of GTV Texture Feature Extracted From Four-Dimensional CT in NSCLC
    Duan, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [33] Analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients
    Yamamoto, T.
    Langner, U.
    Keall, P. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S610 - S610
  • [34] Tibiofibular syndesmosis in asymptomatic ankles: initial kinematic analysis using four-dimensional CT
    Mousavian, A.
    Shakoor, D.
    Hafezi-Nejad, N.
    Haj-Mirzaian, A.
    Netto, C. de Cesar
    Orapin, J.
    Schon, L. C.
    Demehri, S.
    CLINICAL RADIOLOGY, 2019, 74 (07) : 571.e1 - 571.e8
  • [35] Normal standards of fetal behavior assessed by four-dimensional sonography
    Yigiter, Alin Basgul
    Kavak, Zehra N.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2006, 19 (11): : 707 - 721
  • [36] A four-dimensional Analysis of Partitioned Approximate Filters
    Schmidt, Tobias
    Bandle, Maximilian
    Giceva, Jana
    PROCEEDINGS OF THE VLDB ENDOWMENT, 2021, 14 (11): : 2355 - 2368
  • [37] Integration theorems of four-dimensional vector analysis
    McAulay, A
    PHILOSOPHICAL MAGAZINE, 1921, 42 (247): : 197 - 197
  • [38] The Technical Limitations of a Four-dimensional CT System for Radiotherapy Planning
    Smith, D. W.
    Dean, C. J.
    Lilley, J.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 250 - 251
  • [39] Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT
    Taguchi, K
    MEDICAL PHYSICS, 2003, 30 (04) : 640 - 650
  • [40] Analysis of a novel four-dimensional hyperchaotic system
    Liu, Ling
    Liu, Chongxin
    Zhang, Yanbin
    CHINESE JOURNAL OF PHYSICS, 2008, 46 (04) : 386 - 393