Four-Dimensional CT Analysis of Normal Syndesmotic Motion

被引:10
|
作者
Wong, Murray T. [1 ]
Wiens, Charmaine [1 ]
Lamothe, Jeremy [1 ]
Edwards, W. Brent [1 ]
Schneider, Prism S. [1 ]
机构
[1] Univ Calgary, Calgary, AB, Canada
关键词
4DCT; dynamic CT; syndesmosis; reduction; kinematics; DISTAL TIBIOFIBULAR SYNDESMOSIS; COMPUTED-TOMOGRAPHY; CLINICAL IMPORTANCE; ANKLE SYNDESMOSIS; SCREW FIXATION; SUTURE-BUTTON; REDUCTION; MALREDUCTION; INJURIES; BIOMECHANICS;
D O I
10.1177/10711007211015204
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The syndesmosis ligament complex stabilizes the distal tibiofibular joint while allowing for small amounts of physiologic motion. When injured, malreduction of the syndesmosis is the most important factor that contributes to inferior functional outcomes. Syndesmotic reduction is a dynamic measure, which is not adequately captured by conventional computed tomography (CT). Four-dimensional CT (4DCT) can image joints as they move through range of motion (ROM). The aim of this study was to employ 4DCT to determine in vivo syndesmotic motion with ankle ROM in uninjured ankles. Methods: Uninjured ankles were analyzed in patients who had contralateral syndesmotic injuries, as well as a cohort of healthy volunteers with bilateral uninjured ankles. Bilateral ankle 4DCT scans were performed as participants moved their ankles between maximal dorsiflexion and plantarflexion. Multiple measures of syndesmotic width, as well as sagittal translation and fibular rotation, were automatically extracted from 4DCT using a custom program to determine the change in syndesmotic position with ankle ROM. Results: Fifty-eight ankles were analyzed. Measures of syndesmotic width decreased by 0.7 to 1.1 mm as the ankle moved from dorsiflexion to plantarflexion (P < .001 for each measure). The fibula externally rotated by 1.2 degrees with ankle ROM (P < .001), but there was no significant motion in the sagittal plane (P = .43). No participants with bilateral uninjured ankles had a side-to-side difference in syndesmotic width of 2 mm or greater. Conclusion: 4DCT allows accurate, in vivo syndesmotic measurements, which change with ankle ROM, confirming prior work that was limited to biomechanical studies. Side-to-side syndesmotic measurements are consistent within subjects, validating the method of templating syndesmotic reduction off the contralateral ankle, in a consistent ankle position, to achieve anatomic reduction of syndesmotic injury.
引用
收藏
页码:1491 / 1501
页数:11
相关论文
共 50 条
  • [11] PNMC: Four-dimensional conebeam CT reconstruction combining prior network and motion compensation
    Ou Z.
    Xie J.
    Teng Z.
    Wang X.
    Jin P.
    Du J.
    Ding M.
    Li H.
    Chen Y.
    Niu T.
    Computers in Biology and Medicine, 2024, 171
  • [12] Four-dimensional CT Analysis of Wrist Kinematics during Radioulnar Deviation
    Rauch, Aymeric
    Abou Arab, Waled
    Dap, Francois
    Dautel, Gilles
    Blum, Alain
    Teixeira, Pedro Augusto Gondim
    RADIOLOGY, 2018, 289 (03) : 750 - 758
  • [13] Analysis of Artifacts in Four-Dimensional CT Images of Phantoms with Regular Motions
    Sheen, H.
    Han, Y.
    Shin, E.
    MEDICAL PHYSICS, 2010, 37 (06) : 3153 - +
  • [14] A novel system of four-dimensional motion analysis after total hip arthroplasty
    Hagio, K
    Sugano, N
    Nishii, T
    Miki, H
    Otake, Y
    Hattori, A
    Suzuki, N
    Yonenobu, K
    Yoshikawa, H
    Ochi, T
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) : 665 - 670
  • [15] Four-dimensional computed tomography (4D-CT)-based analysis of intra-fractionall esophageal motion
    Michalski, D.
    de Andrade, R. S.
    Heron, D. E.
    Huq, M. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S518 - S519
  • [16] Optimal control of the motion of an object in four-dimensional space
    Timofeyev, D.S.
    Soviet journal of computer and systems sciences, 1992, 30 (05): : 70 - 76
  • [17] Four-dimensional computed tomographic analysis of esophageal mobility during normal respiration
    Dieleman, Edith M. T.
    Senan, Suresh
    Vincent, Andrew
    Lagerwaard, Frank J.
    Slotman, Ben J.
    de Koste, John R. van Sornsen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 775 - 780
  • [18] Four-dimensional analysis of stomatognathic function
    Terajima, Masahiko
    Endo, Mizuki
    Aoki, Yoshimitsu
    Yuuda, Kyouko
    Hayasaki, Haruaki
    Goto, Tazuko K.
    Tokumori, Kenji
    Nakasima, Akihiko
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (02) : 276 - 287
  • [19] Four-Dimensional CT of the Diaphragm in Children: Initial Experience
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 111 - 118
  • [20] Four-dimensional CT in the laboratory has potential for manufacturing
    不详
    INSIGHT, 2018, 60 (12) : 660 - 660