Four-Dimensional CT Analysis of Normal Syndesmotic Motion

被引:10
|
作者
Wong, Murray T. [1 ]
Wiens, Charmaine [1 ]
Lamothe, Jeremy [1 ]
Edwards, W. Brent [1 ]
Schneider, Prism S. [1 ]
机构
[1] Univ Calgary, Calgary, AB, Canada
关键词
4DCT; dynamic CT; syndesmosis; reduction; kinematics; DISTAL TIBIOFIBULAR SYNDESMOSIS; COMPUTED-TOMOGRAPHY; CLINICAL IMPORTANCE; ANKLE SYNDESMOSIS; SCREW FIXATION; SUTURE-BUTTON; REDUCTION; MALREDUCTION; INJURIES; BIOMECHANICS;
D O I
10.1177/10711007211015204
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The syndesmosis ligament complex stabilizes the distal tibiofibular joint while allowing for small amounts of physiologic motion. When injured, malreduction of the syndesmosis is the most important factor that contributes to inferior functional outcomes. Syndesmotic reduction is a dynamic measure, which is not adequately captured by conventional computed tomography (CT). Four-dimensional CT (4DCT) can image joints as they move through range of motion (ROM). The aim of this study was to employ 4DCT to determine in vivo syndesmotic motion with ankle ROM in uninjured ankles. Methods: Uninjured ankles were analyzed in patients who had contralateral syndesmotic injuries, as well as a cohort of healthy volunteers with bilateral uninjured ankles. Bilateral ankle 4DCT scans were performed as participants moved their ankles between maximal dorsiflexion and plantarflexion. Multiple measures of syndesmotic width, as well as sagittal translation and fibular rotation, were automatically extracted from 4DCT using a custom program to determine the change in syndesmotic position with ankle ROM. Results: Fifty-eight ankles were analyzed. Measures of syndesmotic width decreased by 0.7 to 1.1 mm as the ankle moved from dorsiflexion to plantarflexion (P < .001 for each measure). The fibula externally rotated by 1.2 degrees with ankle ROM (P < .001), but there was no significant motion in the sagittal plane (P = .43). No participants with bilateral uninjured ankles had a side-to-side difference in syndesmotic width of 2 mm or greater. Conclusion: 4DCT allows accurate, in vivo syndesmotic measurements, which change with ankle ROM, confirming prior work that was limited to biomechanical studies. Side-to-side syndesmotic measurements are consistent within subjects, validating the method of templating syndesmotic reduction off the contralateral ankle, in a consistent ankle position, to achieve anatomic reduction of syndesmotic injury.
引用
收藏
页码:1491 / 1501
页数:11
相关论文
共 50 条
  • [21] Four-Dimensional PET-CT in Radiation Oncology
    Mawlawi, Osama R.
    Court, Laurence E.
    PET CLINICS, 2013, 8 (01) : 81 - +
  • [22] Assessment of four-dimensional CT image acquisition quality
    Starkschall, G.
    Desai, N.
    Balter, P.
    Prado, K.
    Luo, D.
    Cody, D.
    Pan, T.
    MEDICAL PHYSICS, 2006, 33 (06) : 1986 - 1987
  • [23] Quality assurance of four-dimensional CT image acquisition
    Fitzpatrick, MJ
    Starkschall, G
    Batter, P
    Pan, T
    Antolak, J
    Guerrero, T
    Stevens, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1780 - 1780
  • [24] Four-Dimensional CT Planning for Gastric MALT Lymphoma
    King, J. W.
    Brown, J. G.
    Mauch, P. M.
    Ng, A. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S629 - S629
  • [25] Analysis of Acquisition Parameters That Caused Artifacts in Four-Dimensional (4D) CT Images of Targets Undergoing Regular Motion
    Sheen, H.
    Han, Y.
    Shin, E.
    Min, B.
    Kim, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3652 - 3652
  • [26] Accelerated Partial Breast Irradiation: Use of Four-Dimensional CT for Target Localization and Assessment of Intrafractional Motion
    Liao, Zhi-Wei
    Guan, Xun-Xing
    Li, Feng-Yan
    He, Zhen-Yu
    Xue, Ming
    Huang, Xiao-Yan
    Chen, Li-xin
    ONCOLOGY RESEARCH, 2010, 18 (10) : 503 - 507
  • [27] Quantitative motion analysis of subchromosomal foci in living cells using four-dimensional microscopy
    Bornfleth, H
    Edelmann, P
    Zink, D
    Cremer, T
    Cremer, C
    BIOPHYSICAL JOURNAL, 1999, 77 (05) : 2871 - 2886
  • [28] Evaluation of pisotriquetral motion pattern using four-dimensional CT: initial clinical experience in asymptomatic wrists
    Demehri, S.
    Hafezi-Nejad, N.
    Thakur, U.
    Morelli, J. N.
    Lifchez, S. D.
    Means, K. R.
    Shores, J. T.
    CLINICAL RADIOLOGY, 2015, 70 (12) : 1362 - 1369
  • [29] Motion artifact detection in four-dimensional computed tomography images
    Bouilhol, G.
    Ayadi, M.
    Pinho, R.
    Rit, S.
    Sarrut, D.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [30] Integrability of Dynamic Equations of Generalized Four-Dimensional Pendulum Motion
    Shamolin, M. V.
    LOBACHEVSKII JOURNAL OF MATHEMATICS, 2024, 45 (08) : 3737 - 3759