Safety and Efficacy of MRI Scans in Patients With Implanted Microvascular Coupling Devices

被引:3
|
作者
Phalke, Neelam [1 ]
Thomas, W. Walsh [2 ]
Azzi, James [2 ]
Li, Ryan J. [2 ]
Petrisor, Daniel [3 ]
Wax, Mark K. [2 ]
机构
[1] Louisiana State Univ, Dept Otolaryngol, Sch Med, New Orleans, LA USA
[2] Oregon Hlth & Sci Univ, Dept Otolaryngol, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97239 USA
[3] Oregon Hlth & Sci Univ, Dept Oral Maxillofacial Surg, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97239 USA
来源
LARYNGOSCOPE | 2020年 / 130卷 / 06期
关键词
MRI compatibility; microvascular reconstruction; microvascular coupler; MRI safety; head and neck reconstruction; BIOMEDICAL IMPLANTS; INFORMATION;
D O I
10.1002/lary.28275
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To demonstrate the safety and compatibility of microvascular couplers in patients undergoing postoperative magnetic resonance imaging (MRI) scans. Study Design Retrospective case series. Methods A consecutive review of 1,252 patients undergoing free tissue transfer for head and neck reconstruction at Oregon Health and Sciences University (OHSU) between 2010 and 2017 who had microvascular coupler Synovis, Baxter Deerfield, IL (Synovis Life Technologies, Saint Paul, MN) implantation were reviewed. One hundred fifteen patients had a subsequent MRI scan, which consisted of a variety of Phillips (Amsterdam, Netherlands) MRI machines ranging from 1.0 to 3.0 Tesla (T) in magnetic strength. Results These 115 patients underwent 121 free flaps with 131 couplers (including 32 flow couplers) utilized for venous anastomoses. Couplers ranged in size from 1.5 to 4.0 mm (3.0 mm [42%] followed by 3.5 mm [21%], 2.5 mm [19%], 2.0 mm [10%], 4.0 mm [6%], and 1.5 mm [2%]. Three hundred fifty-nine MRI scans (2 days to 91 months postoperatively) were obtained with 233 MRIs for cancer surveillance, and the remaining were obtained for neurologic disease, injury, or evaluation for metastases. No complications occurred related to the MRI and the metallic components of the coupler or other metal implants, such as reconstruction bars, vascular clips, or metallic surgical mesh. Additionally, no radiology report commented on MRI distortion due to the coupler placement, which contrasts the distortion seen with the other metallic implants. Conclusion Microvascular couplers and their constitutive stainless-steel pins have not been found to cause any complications in a large series of consecutive patients undergoing multiple MRIs with magnetic strength up to 3 T. The U.S. Food and Drug Administration advocates medical alert notification for patients with couplers; however, hesitation regarding potential MRI scanning for surveillance or otherwise is unwarranted. Level of Evidence 4 Laryngoscope, 130:1428-1430, 2020
引用
收藏
页码:1428 / 1430
页数:3
相关论文
共 50 条
  • [31] Patients with cardiac devices should not be excluded from MRI scans, say experts
    Kmietowicz, Zosia
    BMJ-BRITISH MEDICAL JOURNAL, 2018, 362 : k3623
  • [32] Safety of patients with metallic devices during MRI.
    Chauvel, BP
    Cathelineau, G
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 958 - 958
  • [33] The Efficacy and Safety of Microvascular Decompression for Hemifacial Spasm in Elderly Patients
    Jeon, Chul-Jin
    Kong, Doo-Sik
    Lee, Jeong-A
    Park, Kwan
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2010, 47 (06) : 442 - 445
  • [34] Safety of MRI at 1.5 Tesla in patients with implanted sacral nerve neurostimulator
    Elkelini, Mohamed S.
    Hassouna, Mady M.
    EUROPEAN UROLOGY, 2006, 50 (02) : 311 - 316
  • [35] SAFETY OF TRANSCRANIAL MAGNETIC STIMULATION IN PATIENTS WITH ABDOMINALLY IMPLANTED ELECTRONIC DEVICES
    KOFLER, M
    LEIS, AA
    SHERWOOD, AM
    DELAPASSE, JS
    HALTER, JA
    LANCET, 1991, 338 (8777): : 1275 - 1276
  • [36] Response to Comments on "Ensuring Safety of Implanted Devices Under MRI Using Reversed RF Polarization"
    Overall, William R.
    Pauly, John M.
    Stang, Pascal P.
    Scott, Greig C.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1517 - 1517
  • [37] Efficacy of Abatacept in Patients with Rheumatoid Arthritis Assessed By MRI Scans of Bilateral Hands
    Kukida, Yuji
    Kasahara, Akiko
    Seno, Takahiro
    Isoda, Yu
    Sagawa, Tomoya
    Inoue, Takuya
    Kamio, Naoka
    Sagawa, Risa
    Kida, Takashi
    Nakabayashi, Amane
    Nagahara, Hidetake
    Murakami, Ken
    Yamamoto, Aihiro
    Morita, Satoshi
    Ito, Hirotoshi
    Kohno, Masataka
    Kawahito, Yutaka
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [38] Efficacy and safety of oral dofetilide in patients with an implanted defibrillator: A multicenter study
    O'Toole, M
    O'Neill, PG
    Kluger, J
    Bonney, SL
    Billing, CB
    Friedrich, T
    CIRCULATION, 1999, 100 (18) : 794 - 794
  • [39] THE SAFETY OF MRI IN PATIENTS WITH HYBRID CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Liu, Michael
    Pannunzio, Sofia
    Minaskeian, Nareg
    Klooster, Lindsay
    Sorajja, Dan
    Scott, Luis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 245 - 245
  • [40] Improving Safety of MRI in Patients with Deep Brain Stimulation Devices
    Boutet, Alexandre
    Chow, Clement T.
    Narang, Keshav
    Elias, Gavin J. B.
    Neudorfer, Clemens
    Germann, Juergen
    Ranjan, Manish
    Loh, Aaron
    Martin, Alastair J.
    Kucharczyk, Walter
    Steele, Christopher J.
    Hancu, Ileana
    Rezai, Ali R.
    Lozano, Andres M.
    RADIOLOGY, 2020, 296 (02) : 250 - 262