Safety and Efficacy of MRI Scans in Patients With Implanted Microvascular Coupling Devices

被引:3
|
作者
Phalke, Neelam [1 ]
Thomas, W. Walsh [2 ]
Azzi, James [2 ]
Li, Ryan J. [2 ]
Petrisor, Daniel [3 ]
Wax, Mark K. [2 ]
机构
[1] Louisiana State Univ, Dept Otolaryngol, Sch Med, New Orleans, LA USA
[2] Oregon Hlth & Sci Univ, Dept Otolaryngol, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97239 USA
[3] Oregon Hlth & Sci Univ, Dept Oral Maxillofacial Surg, 3181 Sw Sam Jackson Pk Rd, Portland, OR 97239 USA
来源
LARYNGOSCOPE | 2020年 / 130卷 / 06期
关键词
MRI compatibility; microvascular reconstruction; microvascular coupler; MRI safety; head and neck reconstruction; BIOMEDICAL IMPLANTS; INFORMATION;
D O I
10.1002/lary.28275
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To demonstrate the safety and compatibility of microvascular couplers in patients undergoing postoperative magnetic resonance imaging (MRI) scans. Study Design Retrospective case series. Methods A consecutive review of 1,252 patients undergoing free tissue transfer for head and neck reconstruction at Oregon Health and Sciences University (OHSU) between 2010 and 2017 who had microvascular coupler Synovis, Baxter Deerfield, IL (Synovis Life Technologies, Saint Paul, MN) implantation were reviewed. One hundred fifteen patients had a subsequent MRI scan, which consisted of a variety of Phillips (Amsterdam, Netherlands) MRI machines ranging from 1.0 to 3.0 Tesla (T) in magnetic strength. Results These 115 patients underwent 121 free flaps with 131 couplers (including 32 flow couplers) utilized for venous anastomoses. Couplers ranged in size from 1.5 to 4.0 mm (3.0 mm [42%] followed by 3.5 mm [21%], 2.5 mm [19%], 2.0 mm [10%], 4.0 mm [6%], and 1.5 mm [2%]. Three hundred fifty-nine MRI scans (2 days to 91 months postoperatively) were obtained with 233 MRIs for cancer surveillance, and the remaining were obtained for neurologic disease, injury, or evaluation for metastases. No complications occurred related to the MRI and the metallic components of the coupler or other metal implants, such as reconstruction bars, vascular clips, or metallic surgical mesh. Additionally, no radiology report commented on MRI distortion due to the coupler placement, which contrasts the distortion seen with the other metallic implants. Conclusion Microvascular couplers and their constitutive stainless-steel pins have not been found to cause any complications in a large series of consecutive patients undergoing multiple MRIs with magnetic strength up to 3 T. The U.S. Food and Drug Administration advocates medical alert notification for patients with couplers; however, hesitation regarding potential MRI scanning for surveillance or otherwise is unwarranted. Level of Evidence 4 Laryngoscope, 130:1428-1430, 2020
引用
收藏
页码:1428 / 1430
页数:3
相关论文
共 50 条
  • [1] Safety of MRI scans in patients with radiofrequency identification devices
    Randhawa, G. K.
    Graham, R. M.
    Corsar, K.
    Padaki, P.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2020, 58 (01): : 122 - 123
  • [2] Safety of MRI in patients with metal implants and implanted devices
    Sykora, M.
    Traubnerova, R.
    Traubner, P.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2008, 71 (01) : 47 - 52
  • [3] Safety of MRI in patients with implanted deep brain stimulation devices
    Tagliati, Michele
    Jankovic, Joseph
    Pagan, Fernando
    Susatia, Frandy
    Isaias, Ioannis U.
    Okun, Michael S.
    NEUROIMAGE, 2009, 47 : T53 - T57
  • [4] Safety of Implanted Cardiac Devices in an MRI Environment
    Esra Gucuk Ipek
    Saman Nazarian
    Current Cardiology Reports, 2015, 17
  • [5] Safety of Implanted Cardiac Devices in an MRI Environment
    Ipek, Esra Gucuk
    Nazarian, Saman
    CURRENT CARDIOLOGY REPORTS, 2015, 17 (07)
  • [6] MRI of Patients With Implanted Cardiac Devices
    Kalb, Bobby
    Indik, Julia H.
    Ott, Peter
    Martin, Diego R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (03) : 595 - 603
  • [7] The Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices
    Kahan, Joshua
    Papadaki, Anastasia
    White, Mark
    Mancini, Laura
    Yousry, Tarek
    Zrinzo, Ludvic
    Limousin, Patricia
    Hariz, Marwan
    Foltynie, Tom
    Thornton, John
    PLOS ONE, 2015, 10 (06):
  • [8] Cardiac MRI of patients with implanted electrical cardiac devices
    Ainslie, Mark
    Miller, Christopher
    Brown, Benjamin
    Schmitt, Matthias
    POSTGRADUATE MEDICAL JOURNAL, 2014, 90 (1070) : 363 - 369
  • [9] Cardiac MRI of patients with implanted electrical cardiac devices
    Ainslie, Mark
    Miller, Christopher
    Brown, Benjamin
    Schmitt, Matthias
    HEART, 2014, 100 (05) : 363 - 369
  • [10] SAFETY OF MULTIPLE MRI SCANS IN PATIENTS WITH PACEMAKERS OR DEFIBRILLATORS
    Patel, Kavisha
    Tman, Zachariah
    Lin, Andrew
    Hull, Stephanie
    Hall, Peter
    Lee, Roland
    Birgersdotter-Green, Ulrika
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 99 - 99