Selection of pulse oximetry equipment for ambulatory monitoring

被引:0
|
作者
Barratt, CW
Vyas, H
Hayes-Gill, BR
Crowe, JA
机构
[1] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
[2] Queens Med Ctr, Paediat Intens Care Unit, Nottingham NG7 2UH, England
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Primary objective: This communication describes the initial stage of a research project concerning the monitoring of SpO(2) in infants prone to periods of spontaneous oxygen desaturation whilst freely moving around their home environment. The primary aim was to determine an appropriate probe type and site together with an assessment of the suitability of two commercially available oximeter units. Research design: The study comprised 19 comparative tests, totalling 162 hours of recordings at resolution one sample every four seconds. Comparisons are drawn between probes, probe sites and pulse oximeters. Main outcomes/results: The bias and precision is presented with respect to the probe and measurement site. Also, correlation between the trial and reference recordings is considered. Conclusions: It is concluded that ambulatory recording of SpO(2) in infants utilizing equipment suitable for home monitoring can Produce diagnostic data equivalent to that of the Ohmeda 3700 biox, but that an indication of movement artefact may be required for confirmation of accuracy. It became apparent that 'wrap around' probes, used on the index finger or big toe are the most suitable.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [41] INFLIGHT ARTERIAL SATURATION - CONTINUOUS MONITORING BY PULSE OXIMETRY
    COTTRELL, JJ
    LEBOVITZ, BL
    FENNELL, RG
    KOHN, GM
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1995, 66 (02): : 126 - 130
  • [42] Possibilities and limitations of pulse oximetry during intrapartum monitoring
    Knitza, R
    GYNAKOLOGE, 1996, 29 (01): : 52 - 56
  • [43] A wireless monitoring system for pulse-oximetry sensors
    Morón, MJ
    Casilari, E
    Luque, R
    Gázquez, JA
    2005 SYSTEMS COMMUNICATIONS, PROCEEDINGS: ICW 2005, WIRELESS TECHNOLOGIES; ICHSN 2005, HIGH SPEED NETWORKS; ICMCS 2005, MULTIMEDIA COMMUNICATIONS SYSTEMS; SENET 2005, SENSOR NETWORKS, 2005, : 79 - 84
  • [44] A centralized monitoring approach to pulse oximetry for patients on opioids
    Miller P.J.
    Biomedical Instrumentation and Technology, 2017, 51 (05): : 708 - 713
  • [45] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [46] Pulse oximetry for monitoring infants in the delivery room: a review
    Dawson, J. A.
    Davis, P. G.
    O'Donnell, C. P. F.
    Kamlin, C. O. F.
    Morley, C. J.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2007, 92 (01): : F4 - F7
  • [47] Ambulatory pulse oximetry as a clinical aid for the diagnosis and treatment response of radiation pneumonitis
    Scher, Eli D.
    Kim, Sinae
    Deek, Matthew P.
    Ahmed, Inaya
    Kothadia, Jiten P.
    Balasubramanian, Sairam
    Aisner, Joseph
    Goyal, Sharad
    Jabbour, Salma K.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (06) : E635 - E641
  • [48] Wavelength Selection Method with Standard Deviation: Application to Pulse Oximetry
    Vazquez-Jaccaud, Camille
    Paez, Gonzalo
    Strojnik, Marija
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (07) : 1994 - 2009
  • [49] Wavelength Selection Method with Standard Deviation: Application to Pulse Oximetry
    Camille Vazquez-Jaccaud
    Gonzalo Paez
    Marija Strojnik
    Annals of Biomedical Engineering, 2011, 39 : 1994 - 2009
  • [50] An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
    Haahr, Rasmus G.
    Duun, Sune B.
    Toft, Mette H.
    Belhage, Bo
    Larsen, Jan
    Birkelund, Karen
    Thomsen, Erik V.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (01) : 45 - 53