Selection of pulse oximetry equipment for ambulatory monitoring

被引:0
|
作者
Barratt, CW
Vyas, H
Hayes-Gill, BR
Crowe, JA
机构
[1] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
[2] Queens Med Ctr, Paediat Intens Care Unit, Nottingham NG7 2UH, England
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Primary objective: This communication describes the initial stage of a research project concerning the monitoring of SpO(2) in infants prone to periods of spontaneous oxygen desaturation whilst freely moving around their home environment. The primary aim was to determine an appropriate probe type and site together with an assessment of the suitability of two commercially available oximeter units. Research design: The study comprised 19 comparative tests, totalling 162 hours of recordings at resolution one sample every four seconds. Comparisons are drawn between probes, probe sites and pulse oximeters. Main outcomes/results: The bias and precision is presented with respect to the probe and measurement site. Also, correlation between the trial and reference recordings is considered. Conclusions: It is concluded that ambulatory recording of SpO(2) in infants utilizing equipment suitable for home monitoring can Produce diagnostic data equivalent to that of the Ohmeda 3700 biox, but that an indication of movement artefact may be required for confirmation of accuracy. It became apparent that 'wrap around' probes, used on the index finger or big toe are the most suitable.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [21] LED power reduction trade-offs for ambulatory pulse oximetry
    Pelaez, Eduardo Aguilar
    Villegas, Esther Rodriguez
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2296 - 2299
  • [22] Ambulatory oximetry monitoring in patients with severe COPD - A preliminary study
    Pilling, J
    Cutaia, M
    CHEST, 1999, 116 (02) : 314 - 321
  • [23] Wavelength selection for low-saturation pulse oximetry
    Nellcor Puritan Bennett, 4280 Hacienda Drive, Pleasanton, CA 94588, United States
    不详
    IEEE TRANS. BIOMED. ENG., 3 (148-158):
  • [24] PULSE OXIMETRY - A NEW, SIGNIFICANT ADJUNCT TO AMBULATORY PATIENT-EVALUATION
    ANDERSON, AB
    ZWERDLING, RG
    DEWITT, TG
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1988, 142 (04): : 394 - 394
  • [25] Wavelength selection for low-saturation pulse oximetry
    Mannheimer, PD
    Casciani, JR
    Fein, ME
    Nierlich, SL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 148 - 158
  • [26] Variations in physician interpretation of overnight pulse oximetry monitoring
    Ramsey, Rory
    Mehra, Reena
    Strohl, Kingnwn P.
    CHEST, 2007, 132 (03) : 852 - 859
  • [27] Evaluation of pulse oximetry as a monitoring method in avian anesthesia
    Schmitt, PM
    Gobel, T
    Trautvetter, E
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 1998, 12 (02) : 91 - 99
  • [28] Cerebral and Pulse Oximetry Monitoring of Newborns Clinical Observations
    Benni, P.
    Chen, B.
    Fenik, J.
    Rais-Bahrami, K.
    Rivera, O.
    Short, B. L.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S100 - S100
  • [29] Advanced Pulse Oximetry System for Remote Monitoring and Management
    Pak, Ju Geon
    Park, Kee Hyun
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2012,
  • [30] USE OF PULSE OXIMETRY FOR MONITORING TRACHEOSTOMY TUBE OBSTRUCTION
    RAO, AJ
    KOMATSU, T
    KAINUMA, M
    KOH, T
    SHIMADA, Y
    YANAGITA, N
    NAKASHIMA, T
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1988, 50 (05): : 345 - 348