INFLIGHT ARTERIAL SATURATION - CONTINUOUS MONITORING BY PULSE OXIMETRY

被引:0
|
作者
COTTRELL, JJ
LEBOVITZ, BL
FENNELL, RG
KOHN, GM
机构
[1] UNIV PITTSBURGH,MED CTR,DIV RESP ALLERGY & CRIT CARE,PITTSBURGH,PA
[2] UNIV AIRLINES,DEPT MED,CHICAGO,IL
[3] UNIV AIRLINES,DEPT MED,ELK GROVE VILLAGE,IL
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The ability of newer airliners to fly at higher altitudes has resulted in an increased altitude exposure to both airline crews and passengers. This increase in altitude exposure has the potential to place some individuals at risk for desaturation. Using pulse oximetry, the arterial oxygen saturation of 42 airline crew members was continuously monitored on 22 regularly scheduled commercial flights. Mean nadir arterial oxygen saturations fell from 97.0% preflight to 88.6% at cruising altitudes, Pulse oximetry results revealed large variations between individuals. individual nadir saturations ranged from 93% to 80%. Modern aircraft flight may result in desaturations even among healthy aircrew, The effects on human performance remain unknown.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 50 条
  • [1] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [2] CONTINUOUS MONITORING OF ARTERIAL OXYGEN-SATURATION WITH PULSE OXIMETRY DURING TRANSFER TO THE RECOVERY ROOM
    TYLER, IL
    TANTISIRA, B
    WINTER, PM
    MOTOYAMA, EK
    [J]. ANESTHESIA AND ANALGESIA, 1985, 64 (11): : 1108 - 1112
  • [3] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    [J]. ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [4] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    [J]. OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [5] INFLIGHT ARTERIAL SATURATION
    FOWLER, B
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1995, 66 (11): : 1119 - 1120
  • [6] Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
    Jensen, LA
    Onyskiw, JE
    Prasad, NGN
    [J]. HEART & LUNG, 1998, 27 (06): : 387 - 408
  • [7] Trans-abdominal monitoring of fetal arterial oxygen saturation using pulse oximetry
    Mawn, T
    Li, PC
    Nioka, S
    Chance, B
    [J]. PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 227 - 228
  • [8] EFFECTS OF ANEMIA ON PULSE OXIMETRY AND CONTINUOUS MIXED VENOUS HEMOGLOBIN SATURATION MONITORING IN DOGS
    LEE, S
    TREMPER, KK
    BARKER, SJ
    [J]. ANESTHESIOLOGY, 1991, 75 (01) : 118 - 122
  • [9] Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia
    Ottestad, William
    Kasin, Jan Ivar
    Hoiseth, Lars Oivind
    [J]. AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2018, 89 (12) : 1045 - 1049
  • [10] EVALUATION OF PULSE OXIMETRY AS A CONTINUOUS MONITORING TECHNIQUE
    BARRINGTON, K
    FINER, N
    RYAN, A
    ROSSMANN, J
    [J]. PEDIATRIC RESEARCH, 1987, 21 (04) : A352 - A352