40-MHZ MICROMACHINED PMN-PT COMPOSITE ULTRASOUND ARRAY FOR MEDICAL IMAGING

被引:0
|
作者
Li, Sibo [1 ]
Huang, Wenbin [1 ]
Chang, Wei-Yi [1 ]
Jiang, Xiaoning [1 ]
机构
[1] North Carolina State Univ, Raleigh, NC 27695 USA
关键词
PC-MUT; TRANSDUCERS; MHZ;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonography is well known as a relatively low cost and non-invasive modality for real-time imaging. In recent years, various high frequency array transducers have been developed and used for ophthalmology, dermatology, and small animal studies. This paper reports the development of a 48 element 40-MHz ultrasonic array using micromachined lead magnesium niobate-lead titanate (PMN-PT) single crystal 1-3 composite material. Array elements with a pitch of 100-micron were interconnected via a customized flexible circuit. Pulse-echo test showed an average center frequency of 40 MHz and a -6 dB fractional bandwidth of 52%. The -20 dB pulse length was evaluated as 120 ns. The electrical and acoustical separation showed the crosstalk less than-24 dB. An image of a steel wire target phantom was acquired by stacking multiple A-lines. The results demonstrate resolutions exceeding 70 gm axially and 800 gm laterally. Those results imply the great potential of the developed array transducer for the high frequency medical imaging.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Design and analysis of piezoelectric micromachined ultrasonic transducer using high coupling PMN-PT single crystal thin film for ultrasound imaging
    Chen, Mingzhu
    Zhang, Qiaozhen
    Zhao, Xiangyong
    Wang, Feifei
    Liu, Huiling
    Li, Baichuan
    Zhang, Xiangfen
    Luo, Haosu
    SMART MATERIALS AND STRUCTURES, 2021, 30 (05)
  • [22] In vivo microcirculation mapping of human skin keloid by 40-MHz ultrafast ultrasound imaging
    Chen, Pei-Yu
    Hsueh, Yuan-Yu
    Huang, Chih-Chung
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [23] ECG-gated imaging of a mouse heart using a 40-MHz annular array
    Ketterling, Jeffrey A.
    Aristizabal, Orlando
    Turnbull, Daniel H.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 116 - +
  • [24] A PMN- PT Micromachined 1-3 Composite Circular Array for IVUS
    Li, Sibo
    Jiang, Xiaoning
    Tian, Jian
    Han, Pengdi
    Zhang, Chao
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [25] Development of a 35-MHz piezo-composite ultrasound array for medical imaging
    Cannata, JM
    Williams, JA
    Zhou, QF
    Ritter, TA
    Shung, KK
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 224 - 236
  • [26] A 30-MHz piezo-composite ultrasound array for medical imaging applications
    Ritter, TA
    Shrout, TR
    Tutwiler, R
    Shung, KK
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) : 217 - 230
  • [27] 80-MHz Intravascular Ultrasound Transducer Using PMN-PT Free-Standing Film
    Li, Xiang
    Wu, Wei
    Chung, Youngsoo
    Shih, Wan Y.
    Shih, Wei-Heng
    Zhou, Qifa
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (11) : 2281 - 2288
  • [28] Micromachined PIN-PMN-PT Crystal Composite Transducer for High-Frequency Intravascular Ultrasound (IVUS) Imaging
    Li, Xiang
    Ma, Teng
    Tian, Jian
    Han, Pengdi
    Zhou, Qifa
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (07) : 1171 - 1178
  • [29] Influence of cell packing by centrifugation on 40-MHz ultrasound backscatter
    Nam, Kweon-Ho
    Choi, Min Joo
    Yoo, Eun Sook
    Paeng, Dong-Guk
    ULTRASONICS, 2011, 51 (02) : 197 - 201
  • [30] A Novel 6 MHz Phased Array Piezoelectric Micromachined Ultrasound Transducer (pMUT) with 128 Elements for Medical Imaging
    Sadeghpour, Sina
    Zilonova, Ekatrina
    D'Hooge, Jan
    Kraft, Michael
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,