40-MHZ MICROMACHINED PMN-PT COMPOSITE ULTRASOUND ARRAY FOR MEDICAL IMAGING

被引:0
|
作者
Li, Sibo [1 ]
Huang, Wenbin [1 ]
Chang, Wei-Yi [1 ]
Jiang, Xiaoning [1 ]
机构
[1] North Carolina State Univ, Raleigh, NC 27695 USA
关键词
PC-MUT; TRANSDUCERS; MHZ;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonography is well known as a relatively low cost and non-invasive modality for real-time imaging. In recent years, various high frequency array transducers have been developed and used for ophthalmology, dermatology, and small animal studies. This paper reports the development of a 48 element 40-MHz ultrasonic array using micromachined lead magnesium niobate-lead titanate (PMN-PT) single crystal 1-3 composite material. Array elements with a pitch of 100-micron were interconnected via a customized flexible circuit. Pulse-echo test showed an average center frequency of 40 MHz and a -6 dB fractional bandwidth of 52%. The -20 dB pulse length was evaluated as 120 ns. The electrical and acoustical separation showed the crosstalk less than-24 dB. An image of a steel wire target phantom was acquired by stacking multiple A-lines. The results demonstrate resolutions exceeding 70 gm axially and 800 gm laterally. Those results imply the great potential of the developed array transducer for the high frequency medical imaging.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] High Frequency PMN-PT 1-3 Composite Transducer for Ultrasonic Imaging Application
    Sun, Ping
    Wang, Gaofeng
    Wu, Dawei
    Zhu, Benpeng
    Hu, Changhong
    Liu, Changgeng
    Djuth, Frank T.
    Zhou, Qifa
    Shung, K. Kirk
    FERROELECTRICS, 2010, 408 : 120 - 128
  • [42] Single crystal PMN-PT and PZN-PT ultrasonic imaging arrays
    Zipparo, MJ
    Oakley, CG
    PROCEEDINGS OF THE 2001 12TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, VOLS I AND II, 2001, : 111 - 114
  • [43] Fabrication and performance of a 40-MHz linear array based on a 1-3 composite with geometric elevation focusing
    Brown, Jeremy A.
    Foster, F. Stuart
    Needles, Andrew
    Cherin, Emmanuel
    Lockwood, Geoffrey R.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1888 - 1894
  • [44] Sol-gel derived PMN-PT thick films for high frequency ultrasound linear array applications
    Zhu, B. P.
    Wu, D. W.
    Zhang, Y.
    Ou-Yang, J.
    Chen, S.
    Yang, X. F.
    CERAMICS INTERNATIONAL, 2013, 39 (08) : 8709 - 8714
  • [45] 40 MHz piezo-composite linear array for medical imaging and integration in a high resolution system
    Bantignies, Claire
    Mauchamp, Pascal
    Dufait, Remi
    Levassort, Franck
    Mateo, Tony
    Gregoire, Jean-Marc
    Ossant, Frederic
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 226 - 229
  • [46] PIN-PMN-PT Single Crystal 1-3 Composite-based 20 MHz Ultrasound Phased Array
    Zhou, Wei
    Zhang, Tao
    Ou-Yang, Jun
    Yang, Xiaofei
    Wu, Dawei
    Zhu, Benpeng
    MICROMACHINES, 2020, 11 (05)
  • [47] Development of Nonlinear Ultrasound System Using PMN-PT Piezoelectric Crystal
    Mihara, T.
    Oliara, Y.
    Yamanaka, K.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 5, 2009, : 161 - 164
  • [48] Effects of Composition Segregation in PMN-PT Crystals on Ultrasound Transducer Performance
    Jiang, Zibo
    Hou, Chenxue
    Fei, Chunlong
    Li, Zhaoxi
    Ye, Zuo-Guang
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (02) : 795 - 802
  • [49] Characterization of PMN-PT piezoelectric single crystal and PMN-PT 1-3 composite at elevated temperatures by electrical impedance resonance analysis
    Wu, Zhengbin
    Xi, Kui
    ULTRASONICS, 2014, 54 (05) : 1318 - 1322
  • [50] Thermal assessment of 40-MHz ultrasound at soft tissue-bone interfaces
    Duckett, AS
    Reid, AD
    Leamen, L
    Cucevic, V
    Foster, FS
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (05): : 665 - 673