Accuracy and utility of a 10-test disk blood glucose meter

被引:8
|
作者
Kendall, DM
Kaplan, RA
Paulson, CF
Parkes, JL
Tideman, AM
机构
[1] Bayer Healthcare LLC, Elkhart, IN 46514 USA
[2] Int Diabet Ctr, Minneapolis, MN USA
[3] E Bay Clin Trial Ctr, Concord, CA USA
关键词
blood glucose self-monitoring; diabetes mellitus; reagent strips; patient satisfaction; blood glucose;
D O I
10.1016/j.diabres.2004.05.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the clinical accuracy, precision, and ease-of-use of a whole blood referenced glucose meter system that uses a 10-test disk (Ascensia((R)) Confirm(TM) Blood Glucose Monitoring System, Bayer Healthcare LLC). The meter system was tested by 100 subjects and eight health care professionals at two separate diabetes centers. Meter blood glucose test results, obtained by the subjects and health care professionals, were accurate and correlated well when compared with laboratory results. The means of the subject and healthcare professional blood glucose results were within 4.8% of the laboratory mean glucose result. When compared with laboratory results, the correlation coefficient was 0.96 for subject meter results and 0.97 for health care professional meter results. Error grid analyses demonstrated that all subject and health care professional blood glucose measurements fell within zones A and B ('no effect on clinical action' and 'altered clinical action with little or no effect on clinical outcome,' respectively). Ninety-three percent (93%) of subjects rated the meter system favorably on an 'ease-of-use' questionnaire. A majority of subjects correctly performed blood glucose self-monitoring tasks simply by reviewing the user guide. In summary, this unique meter that uses a 10-test disk was shown to be both accurate and precise, and subjects with diabetes were able to use the system properly with minimal instructions. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [41] Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room
    Karon, Brad S.
    Donato, Leslie J.
    Larsen, Chelsie M.
    Siebenaler, Lindsay K.
    Wells, Amy E.
    Wood-Wentz, Christina M.
    Shirk-Marienau, Mary E.
    Curry, Timothy B.
    ANESTHESIOLOGY, 2017, 127 (03) : 466 - 474
  • [42] Patient Satisfaction With a New, High Accuracy Blood Glucose Meter That Provides Personalized Guidance, Insight, and Encouragement
    Katz, Laurence B.
    Stewart, Lorna
    Guthrie, Brian
    Cameron, Hilary
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (02): : 318 - 323
  • [43] BLOOD-GLUCOSE DETERMINATION IN INFANTS AND CHILDREN - REFLECTANCE METER ENZYME TEST STRIP SYSTEM
    HAWORTH, JC
    VANWOERT, M
    DILLING, LA
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1972, 123 (05): : 469 - &
  • [44] An assessment of the Boehringer Advantage blood glucose meter
    Duly, EB
    Trinick, TR
    Grimason, P
    ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 : 422 - 423
  • [45] BLOOD-GLUCOSE MEASUREMENTS WITH A REFLECTANCE METER
    HENDRY, PIA
    MEDICAL JOURNAL OF AUSTRALIA, 1973, 1 (22) : 1120 - 1121
  • [46] EVALUATION OF A BLOOD-GLUCOSE REFLECTANCE METER
    HAY, WW
    OSBERG, IM
    CLINICAL RESEARCH, 1982, 30 (01): : A142 - A142
  • [47] Haematocrit and the Boehringer Advantage blood glucose meter
    Wiener, K
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 325 - 326
  • [48] Addition of further blood to the Boehringer Advantage blood glucose meter
    Jones, GRD
    Penteado, P
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 687 - 687
  • [49] FALSELY LOW BLOOD-GLUCOSE READINGS BY A BLOOD-GLUCOSE METER SYSTEM
    EVANS, JR
    MCINTOSH, JP
    HARTUNG, H
    ANDERSON, C
    SAWERS, JSA
    DIABETIC MEDICINE, 1994, 11 (03) : 326 - 327
  • [50] Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening
    Boriboonhirunsarn, Dittakarn
    Robkhonburi, Amporn
    Asad-dehghan, Maria
    DIABETOLOGY INTERNATIONAL, 2022, 13 (03) : 561 - 565