Accuracy and utility of a 10-test disk blood glucose meter

被引:8
|
作者
Kendall, DM
Kaplan, RA
Paulson, CF
Parkes, JL
Tideman, AM
机构
[1] Bayer Healthcare LLC, Elkhart, IN 46514 USA
[2] Int Diabet Ctr, Minneapolis, MN USA
[3] E Bay Clin Trial Ctr, Concord, CA USA
关键词
blood glucose self-monitoring; diabetes mellitus; reagent strips; patient satisfaction; blood glucose;
D O I
10.1016/j.diabres.2004.05.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the clinical accuracy, precision, and ease-of-use of a whole blood referenced glucose meter system that uses a 10-test disk (Ascensia((R)) Confirm(TM) Blood Glucose Monitoring System, Bayer Healthcare LLC). The meter system was tested by 100 subjects and eight health care professionals at two separate diabetes centers. Meter blood glucose test results, obtained by the subjects and health care professionals, were accurate and correlated well when compared with laboratory results. The means of the subject and healthcare professional blood glucose results were within 4.8% of the laboratory mean glucose result. When compared with laboratory results, the correlation coefficient was 0.96 for subject meter results and 0.97 for health care professional meter results. Error grid analyses demonstrated that all subject and health care professional blood glucose measurements fell within zones A and B ('no effect on clinical action' and 'altered clinical action with little or no effect on clinical outcome,' respectively). Ninety-three percent (93%) of subjects rated the meter system favorably on an 'ease-of-use' questionnaire. A majority of subjects correctly performed blood glucose self-monitoring tasks simply by reviewing the user guide. In summary, this unique meter that uses a 10-test disk was shown to be both accurate and precise, and subjects with diabetes were able to use the system properly with minimal instructions. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [21] INTERFERENTS IN GLUCOSE DETERMINATION DO NOT INFLUENCE THE HOSPITAL POC GLUCOSE METER STATSTRIP IN ACCURACY AND PRECISION OF BLOOD GLUCOSE MEASUREMENT
    Schoendorf, T.
    Forst, T.
    Pfuetzner, A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S687 - S687
  • [22] ACCURACY OF 2 SYSTEMS FOR BLOOD-GLUCOSE MONITORING WITHOUT A METER (CHEMSTRIP VISIDEX)
    SILVERSTEIN, JH
    ROSENBLOOM, AL
    SPILLAR, RP
    PENDERGAST, JF
    DIABETES, 1983, 32 : A81 - A81
  • [23] ACCURACY OF 2 SYSTEMS FOR BLOOD-GLUCOSE MONITORING WITHOUT A METER (CHEMSTRIP VISIDEX)
    SILVERSTEIN, JH
    ROSENBLOOM, AL
    CLARKE, DW
    SPILLAR, R
    PENDERGAST, JF
    DIABETES CARE, 1983, 6 (06) : 533 - 535
  • [24] ACCURACY OF OFF-LABEL USE OF BLOOD GLUCOSE METER IN THE CRITICAL CARE POPULATION
    Stewart, Amy
    Seibert, Karen
    Villines, Dana
    Saeedi, Joel
    Chaiban, Joumana
    Yasmeen, Tahira
    Ries, Michael
    CRITICAL CARE MEDICINE, 2020, 48
  • [25] MEASUREMENT OF BLOOD-GLUCOSE IN NEONATE USING TEST STRIPS WITH COLOR METER
    CAVELL, B
    SVENNINGSEN, N
    THULIN, T
    SCHERSTEN, B
    ACTA PAEDIATRICA SCANDINAVICA, 1972, 61 (03): : 392 - +
  • [26] 10/10 Accuracy Analysis of a Self-Monitoring Blood Glucose System
    Katz, Laurence B.
    Smith, Antony
    Cameron, Hilary
    Setford, Steven
    Grady, Mike
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (03): : 717 - 718
  • [27] THE CLINICAL ACCURACY OF A GLUCOSE REFLECTANCE METER IN NEONATES
    SESHIA, MMK
    LEROUX, ML
    PEDIATRIC RESEARCH, 1991, 29 (04) : A234 - A234
  • [28] Accuracy of glucose meter use in gestational diabetes
    Ryan, EA
    Nguyen, G
    DIABETES, 2000, 49 : A86 - A86
  • [29] Assessing Glucose Meter Accuracy: The Details Matter!
    Liang, Yafen
    Rice, Mark J.
    ANESTHESIOLOGY, 2018, 128 (05) : 1044 - 1045
  • [30] Accuracy of portable human glucose meter (Accu-chek® Performa) for blood glucose measurement in newborn piglets
    Nuntapaitoon, Morakot
    Sirisawadi, Sujin
    Asawakarn, Sariya
    Tummaruk, Padet