Accuracy and utility of a 10-test disk blood glucose meter

被引:8
|
作者
Kendall, DM
Kaplan, RA
Paulson, CF
Parkes, JL
Tideman, AM
机构
[1] Bayer Healthcare LLC, Elkhart, IN 46514 USA
[2] Int Diabet Ctr, Minneapolis, MN USA
[3] E Bay Clin Trial Ctr, Concord, CA USA
关键词
blood glucose self-monitoring; diabetes mellitus; reagent strips; patient satisfaction; blood glucose;
D O I
10.1016/j.diabres.2004.05.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the clinical accuracy, precision, and ease-of-use of a whole blood referenced glucose meter system that uses a 10-test disk (Ascensia((R)) Confirm(TM) Blood Glucose Monitoring System, Bayer Healthcare LLC). The meter system was tested by 100 subjects and eight health care professionals at two separate diabetes centers. Meter blood glucose test results, obtained by the subjects and health care professionals, were accurate and correlated well when compared with laboratory results. The means of the subject and healthcare professional blood glucose results were within 4.8% of the laboratory mean glucose result. When compared with laboratory results, the correlation coefficient was 0.96 for subject meter results and 0.97 for health care professional meter results. Error grid analyses demonstrated that all subject and health care professional blood glucose measurements fell within zones A and B ('no effect on clinical action' and 'altered clinical action with little or no effect on clinical outcome,' respectively). Ninety-three percent (93%) of subjects rated the meter system favorably on an 'ease-of-use' questionnaire. A majority of subjects correctly performed blood glucose self-monitoring tasks simply by reviewing the user guide. In summary, this unique meter that uses a 10-test disk was shown to be both accurate and precise, and subjects with diabetes were able to use the system properly with minimal instructions. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [31] Accuracy Of A Handheld Blood Glucose Monitor During Exercise And An Oral Glucose Tolerance Test
    Peterson, James R.
    Granderson, Davoncie M.
    Camic, Clayton L.
    Chomentowski, Peter J.
    Howell, Steven M.
    Sebastiao, Emerson
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 289 - 289
  • [32] EXACTECH BLOOD-GLUCOSE METER
    不详
    DIABETIC MEDICINE, 1995, 12 (05) : 450 - 450
  • [33] ACCURACY ASSESSMENT OF THE CONTOUR TS BLOOD GLUCOSE MONITORING SYSTEM CONTAINING AN UPDATED METER ALGORITHM
    Harrison, B.
    Simmons, D. A.
    Warchal-Windham, M. E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A81 - A81
  • [34] Jetting Dispenser Height Effect on the Accuracy of Test Strip for Blood Glucose
    Kim, Kun-Yong
    Lee, Yi-Cheng
    Chang, Ho
    Lee, Rahn-Fang
    Wu, Hong-Wei
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (01) : 109 - 116
  • [35] Jetting Dispenser Height Effect on the Accuracy of Test Strip for Blood Glucose
    Kun-Yong Kim
    Yi-Cheng Lee
    Ho Chang
    Rahn-Fang Lee
    Hong-Wei Wu
    Journal of Medical and Biological Engineering, 2019, 39 : 109 - 116
  • [36] Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs
    Johnson, Beth M.
    Fry, Michael M.
    Flatland, Bente
    Kirk, Claudia A.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2009, 235 (11): : 1309 - 1313
  • [37] Assessing Glucose Meter Accuracy: The Details Matter! In Reply
    Karon, Brad S.
    Donato, Leslie J.
    Mogensen, Chelsie M.
    Siebenaler, Lindsay K.
    Wells, Amy E.
    Wood-Wentz, Christina M.
    Marienau, Mary E.
    Curry, Timothy B.
    ANESTHESIOLOGY, 2018, 128 (05) : 1045 - 1046
  • [38] Accuracy of Blood Glucose Measurement and Blood Glucose Targets
    Eerdekens, Gert-Jan
    Rex, Steffen
    Mesotten, Dieter
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (03): : 553 - 559
  • [39] EDUCATION: A MAJOR ISSUE FOR GLUCOSE METER RESULT ACCURACY
    Abada, B.
    Philippe, M.
    Fillee, C.
    ACTA CLINICA BELGICA, 2010, 65 (03): : 214 - 214
  • [40] Development of the portable blood glucose meter for self-monitoring of blood glucose
    Li, Qi
    Yuan, Jingqi
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6735 - 6738