Accuracy and utility of a 10-test disk blood glucose meter

被引:8
|
作者
Kendall, DM
Kaplan, RA
Paulson, CF
Parkes, JL
Tideman, AM
机构
[1] Bayer Healthcare LLC, Elkhart, IN 46514 USA
[2] Int Diabet Ctr, Minneapolis, MN USA
[3] E Bay Clin Trial Ctr, Concord, CA USA
关键词
blood glucose self-monitoring; diabetes mellitus; reagent strips; patient satisfaction; blood glucose;
D O I
10.1016/j.diabres.2004.05.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the clinical accuracy, precision, and ease-of-use of a whole blood referenced glucose meter system that uses a 10-test disk (Ascensia((R)) Confirm(TM) Blood Glucose Monitoring System, Bayer Healthcare LLC). The meter system was tested by 100 subjects and eight health care professionals at two separate diabetes centers. Meter blood glucose test results, obtained by the subjects and health care professionals, were accurate and correlated well when compared with laboratory results. The means of the subject and healthcare professional blood glucose results were within 4.8% of the laboratory mean glucose result. When compared with laboratory results, the correlation coefficient was 0.96 for subject meter results and 0.97 for health care professional meter results. Error grid analyses demonstrated that all subject and health care professional blood glucose measurements fell within zones A and B ('no effect on clinical action' and 'altered clinical action with little or no effect on clinical outcome,' respectively). Ninety-three percent (93%) of subjects rated the meter system favorably on an 'ease-of-use' questionnaire. A majority of subjects correctly performed blood glucose self-monitoring tasks simply by reviewing the user guide. In summary, this unique meter that uses a 10-test disk was shown to be both accurate and precise, and subjects with diabetes were able to use the system properly with minimal instructions. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [1] ACCURACY OF BLOOD-GLUCOSE MEASUREMENTS USING A REFLECTANCE METER
    DENNIS, PM
    MEDICAL JOURNAL OF AUSTRALIA, 1976, 1 (15) : 552 - 552
  • [2] ACCURACY OF BLOOD-GLUCOSE MEASUREMENTS USING A REFLECTANCE METER
    DENNIS, PM
    LARKIN, MA
    ENNIS, GC
    MEDICAL JOURNAL OF AUSTRALIA, 1976, 1 (05) : 124 - 125
  • [3] ACCURACY OF BLOOD-GLUCOSE MEASUREMENTS USING A REFLECTANCE METER
    CROMWELLWOOD, B
    MEDICAL JOURNAL OF AUSTRALIA, 1976, 1 (12) : 415 - 415
  • [4] An accuracy of blood glucose obtained from glucose meter [LDQUO]Standard Gluconavii® GDH Blood Glucose Meter [RDQUO] by testing with arterial and neonatal blood samples
    Thongsukkeang, K.
    Treebuphachatsakul, W.
    Apiratmateekul, N.
    CLINICA CHIMICA ACTA, 2022, 530 : S98 - S98
  • [5] Assessing glucose meter accuracy
    Arabadjief, Darius
    Nichols, James H.
    CURRENT MEDICAL RESEARCH AND OPINION, 2006, 22 (11) : 2167 - 2174
  • [6] System accuracy assessments with a blood glucose meter with combined glucose and ß-hydroxybutyrate measurement capabilities
    Weissenbacher, Sylvia
    Yang, Chen-Yu
    Kuan, Tang-Chin
    Demircik, Filiz
    Hanna, Mina
    Pfuetzner, Andreas
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2019, 19 (11) : 1043 - 1048
  • [7] MEASURING NEONATAL BLOOD GLUCOSE WITH A REFLECTANCE METER AND TEST STRIPS
    LEVKOFF, AH
    URQUHART, C
    DUNCAN, R
    GERSHANIK, JJ
    SOUTHERN MEDICAL JOURNAL, 1970, 63 (12) : 1497 - +
  • [8] MEASURING NEONATAL BLOOD GLUCOSE WITH A REFLECTANCE METER AND TEST STRIPTS
    LEVKOFF, AH
    DUNCAN, RC
    URQUHART, C
    GERSHANIK, JJ
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1971, 7 (04): : 598 - +
  • [9] Design & Implementation of a Low Cost Blood Glucose Meter with High Accuracy
    Saha, Shumit
    Sarker, Nayan
    Hira, Avijit
    2014 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT 2014), 2014,
  • [10] USE OF TEST STRIPS WITH COLOUR METER TO MEASURE BLOOD-GLUCOSE
    BALAZS, N
    BRADSHAW, R
    WELBORN, T
    LANCET, 1970, 1 (7658): : 1232 - &