COMPARISON ON TOTAL LUMINOUS FLUX MEASUREMENT OF SPECTROGONIOPHOTOMETER AND GONIOPHOTOMETER

被引:0
|
作者
Zhao, W. [1 ]
Hui, L. [1 ]
Jian, L. [2 ]
Haisu, Z. [1 ]
Tong, C. [3 ]
机构
[1] Natl Inst Metrol, Beijing, Peoples R China
[2] Beijing Normal Univ, Beijing 100875, Peoples R China
[3] Xiamen Inst Measurement & Testing, Xiamen, Peoples R China
关键词
spectrogoniophotometer; spectroradiometer; LED measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A facility of spectrogoniophotometer in NIM has been setup, and we make a comparison between the spectrogoniophotometer and a traditional goniophotometer. The differences on total luminous flux measurement are similar to 0.1% for tungsten lamp and similar to 2% for LED (except blue). The facility shows the spectral mismatch correction factor F-star(phi,theta) spatial distribution for common white LED light source is nonuniform and we recommend to introduce this factor to the usage of a traditional goniophotometer for LED light source.
引用
收藏
页码:634 / 636
页数:3
相关论文
共 50 条
  • [1] LUMINOUS FLUX MEASUREMENT AT THE NPRL BY MEANS OF A NEW GONIOPHOTOMETER.
    Monard, L.A.G.
    Hengstberger, F.
    Appenroth, T.
    Thain, M.E.
    Kok, C.J.
    Turner, R.
    Licht-Forschung, 1982, 4 (02): : 99 - 103
  • [2] Research on measurement of total luminous flux of single LED in direct comparison method
    Huang, Biyong
    Lai, Lei
    Yin, Dejin
    Cheng, Weihai
    Lin, Fangsheng
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [3] Construction of Two-Axis Goniophotometer for Measurement of Spatial Distribution of a Light Source and Calculation of Luminous Flux
    Sametoglu, F.
    ACTA PHYSICA POLONICA A, 2011, 119 (06) : 783 - 791
  • [4] A NEW GONIOPHOTOMETER FOR THE CALIBRATION OF SMALL LUMINOUS FLUX STANDARD LAMPS
    THAIN, ME
    HENGSTBERGER, F
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (06): : 675 - 678
  • [5] The total luminous flux measurement of high-power LEDs
    Li, Tiecheng
    Lin, Fangsheng
    Huang, Biyong
    Ji, Muyao
    Shi, Leibing
    Xia, Ming
    Lai, Lei
    OPTOELECTRONIC DEVICES AND INTEGRATION; AND TERAHERTZ TECHNOLOGY AND APPLICATIONS (AOPC 2019), 2019, 11334
  • [6] Luminous flux measurement
    Rastello, M.L.
    Rossi, G.
    Soardo, P.
    Lighting research & technology, 1988, 20 (04): : 189 - 193
  • [7] Comparison of luminous intensity distributions measured on luminaire turning and mirror goniophotometer
    Csuti, Peter
    Szabo, Ferenc
    Dubnicka, Roman
    PROCEEDINGS OF 2016 IEEE LIGHTING CONFERENCE OF THE VISEGRAD COUNTRIES (LUMEN V4), 2016,
  • [8] Total luminous flux measurement for flexible surface sources with an integrating sphere photometer
    Yu, Hsueh-Ling
    Liu, Wen-Chun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (01)
  • [9] Realization of total spectral radiant flux scale at NMIJ with a goniophotometer/spectroradiometer
    Godo, Kenji
    Niwa, Kazuki
    Kinoshita, Kenichi
    Ichino, Yoshiro
    Zama, Tatsuya
    METROLOGIA, 2016, 53 (02) : 853 - 859
  • [10] The measurement of luminous flux for single LEDs
    Li, Tiecheng
    Zhu, Jiangang
    Ji, Muyao
    Lin, Fangsheng
    Huang, Biyong
    Lai, Lei
    Shi, Leibing
    Xia, Ming
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621