A facility of spectrogoniophotometer in NIM has been setup, and we make a comparison between the spectrogoniophotometer and a traditional goniophotometer. The differences on total luminous flux measurement are similar to 0.1% for tungsten lamp and similar to 2% for LED (except blue). The facility shows the spectral mismatch correction factor F-star(phi,theta) spatial distribution for common white LED light source is nonuniform and we recommend to introduce this factor to the usage of a traditional goniophotometer for LED light source.
引用
收藏
页码:634 / 636
页数:3
相关论文
共 50 条
  • [21] TOTAL LUMINOUS FLUX - A POSSIBLE RESPONSE DETERMINANT FOR NORMAL MONKEY
    SCHILDER, P
    PASIK, P
    PASIK, T
    SCIENCE, 1967, 158 (3802) : 806 - &
  • [22] Temperature dependence correction method of LED filament lamp for total luminous flux calibration based on voltage measurement
    Weiqiang, Zhao
    Jinyun, Yan
    Hui, Liu
    Ying, Su
    Yandong, Lin
    METROLOGIA, 2021, 58 (04)
  • [23] 6TH COMPARISON OF NATIONAL STANDARDS OF LUMINOUS INTENSITY AND OF LUMINOUS FLUX (1985)
    BONHOURE, J
    METROLOGIA, 1987, 24 (04) : 157 - 162
  • [24] Measurement of differential gloss using a μ-goniophotometer
    Farnand, Susan
    Nilosek, David
    NIP 23: 23RD INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, TECHNICAL PROGRAM AND PROCEEDINGS/DIGITAL FABRICATION 2007, 2007, : 368 - 372
  • [25] ABSOLUTE LUMINOUS FLUX MEASUREMENT OF LAMPS USING THE ULBRICHT SPHERE
    Jordan, Werner
    Halbritter, Werner
    Steudtner, Walter
    Binder, Ulrich
    Wagner, Norbert
    PROCEEDINGS OF THE CIE EXPERT SYMPOSIUM ON SPECTRAL AND IMAGING METHODS FOR PHOTOMETRY AND RADIOMETRY, 2010, : 119 - 125
  • [26] Methods of estimating luminous flux of the backlight module by luminance measurement
    Fung, Rong-Fong
    Chang, Liang-Kang
    Lin, Chi-Feng
    OPTICAL ENGINEERING, 2007, 46 (01)
  • [27] Research on the Influence of Baffle in Luminous Flux Measurement with Integrating Sphere
    Lin, Fangsheng
    Li, Tiecheng
    Huang Biyong
    Yin, Dejin
    Ji, Muyao
    Lai, Lei
    Xia, Ming
    AOPC 2017: OPTOELECTRONICS AND MICRO/NANO-OPTICS, 2017, 10460
  • [28] Measurement of the Luminous Flux of Fluorescent Lamps in a Spherical Photometer.
    Golik, W.
    Krzeszowiak, T.
    Licht-Forschung, 1983, 5 (01): : 49 - 52
  • [29] MEASUREMENT OF GEOMETRICALLY TOTAL SPECTRAL FLUX
    MOHAN, K
    SCHAEFER, AR
    ZALEWSKI, EF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1974, 64 (10) : 1405 - 1405
  • [30] PULSATION OF LUMINOUS FLUX OF LIGHT EMITTING DIODES AND FEATURES OF THEIR MEASUREMENT AND RATIONING
    Georgobiani, Sergei A.
    Klykov, Mikhail E.
    Lobanov, Mikhail V.
    LIGHT & ENGINEERING, 2015, 23 (03): : 73 - 77