Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients

被引:17
|
作者
Chang, Pingjun [1 ,2 ]
Lin, Lei [1 ,2 ]
Li, Zhangliang [1 ,2 ]
Wang, Li [3 ]
Huang, Jinhai [1 ,2 ]
Zhao, Yun-e [1 ,2 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou Xueyuan Rd, Wenzhou 325102, Zhejiang, Peoples R China
[2] Minist Hlth, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
基金
中国国家自然科学基金;
关键词
Pediatric cataract; Calculation formulas; Intraocular lens power; Prediction errors; REFRACTIVE OUTCOMES; SURGICAL OUTCOMES; IMPLANTATION; CHILDREN; SURGERY; EYES;
D O I
10.1007/s00417-020-04617-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy of the eight formulas for intraocular lens (IOL) power calculation in pediatric cataract patients. Methods A retrospective study. A total of 68 eyes (68 patients) that underwent uneventful cataract surgery and posterior chamber IOL implantation in the capsular bag were enrolled. We compared the calculation accuracy of the 8 formulas at 1 month postoperatively and performed subgroup analysis according to age or axial length (AL). Results The mean age at surgery was 34.07 +/- 24.60 months and mean AL was 21.12 +/- 1.42 mm. The mean prediction errors (PE) of eight formulas for all patients were as follows: SRK II (- 0.66), SRK/T (- 0.44), Holladay 1 (- 0.36), Hoffer Q (- 0.09), Olsen (0.71), Barrett (0.37), Holladay 2 (- 0.70), and Haigis (0.50). There was significant difference among the 8 formulas (p < 0.0001), while no significant difference of absolute PE was found among the 8 formulas in all patients (p = 0.053). Moreover, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formula was relatively accurate in 34% and 39% of eyes, respectively. While in patients older than 2 or with AL > 21 mm, Barrett and Haigis formulas were better (58% and 47% for Barrett, 52% and 53% for Haigis). Conclusion Overall, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formulas were relatively accurate, while Barrett and Haigis formulas were better in patients older than 2 or with AL > 21 mm.
引用
收藏
页码:1123 / 1131
页数:9
相关论文
共 50 条
  • [41] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial hyperopia
    Stopyra, Wiktor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [42] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia
    Stopyra, Wiktor
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (02) : 225 - 230
  • [43] Accuracy of the refractive prediction determined by intraocular lens power calculation formulas in high myopia
    Shrivastava, Ankur K.
    Behera, Pranayee
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (11) : 1905 - +
  • [44] Accuracy of 20 Intraocular Lens Power Calculation Formulas in Medium-Long Eyes
    Stopyra, Wiktor
    Voytsekhivskyy, Oleksiy
    Grzybowski, Andrzej
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (07) : 1893 - 1907
  • [45] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Jia-Qing
    Zou, Xu-Yuan
    Zheng, Dan-Ying
    Chen, Wei-Rong
    Sun, Ao
    Luo, Li-Xia
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 943 - 948
  • [46] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Jia-Qing Zhang
    Xu-Yuan Zou
    Dan-Ying Zheng
    Wei-Rong Chen
    Ao Sun
    Li-Xia Luo
    International Journal of Ophthalmology, 2019, (06) : 943 - 948
  • [47] Accuracy of Intraocular Lens Power Calculation in Children With Vitrectomized Eyes Undergoing Cataract Surgery
    Agarkar, Sumita
    Mailankody, Swathi
    Srinivasan, Ramyaa
    Raman, Rajiv
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2021, 58 (02) : 126 - 131
  • [48] Comparison of 9 intraocular lens power calculation formulas
    Cooke, David L.
    Cooke, Timothy L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1157 - 1164
  • [49] Accuracy of 8 intraocular lens calculation formulas in relation to anterior chamber depth in patients with normal axial lengths
    Gokce, Sabite Emine
    De Oca, Ildamaris Montes
    Cooke, David L.
    Wang, Li
    Koch, Douglas D.
    Al-Mohtaseb, Zaina
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (03): : 362 - 368
  • [50] Precision of bag-in-the-lens intraocular lens power calculation in different age groups of pediatric cataract patients: Report of the Giessen Pediatric Cataract Study Group
    Lytvynchuk, Lyubomyr M.
    Thiele, Maximilian, V
    Schmidt, Werner
    Lorenz, Birgit
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1372 - 1379