Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients

被引:17
|
作者
Chang, Pingjun [1 ,2 ]
Lin, Lei [1 ,2 ]
Li, Zhangliang [1 ,2 ]
Wang, Li [3 ]
Huang, Jinhai [1 ,2 ]
Zhao, Yun-e [1 ,2 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou Xueyuan Rd, Wenzhou 325102, Zhejiang, Peoples R China
[2] Minist Hlth, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
基金
中国国家自然科学基金;
关键词
Pediatric cataract; Calculation formulas; Intraocular lens power; Prediction errors; REFRACTIVE OUTCOMES; SURGICAL OUTCOMES; IMPLANTATION; CHILDREN; SURGERY; EYES;
D O I
10.1007/s00417-020-04617-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy of the eight formulas for intraocular lens (IOL) power calculation in pediatric cataract patients. Methods A retrospective study. A total of 68 eyes (68 patients) that underwent uneventful cataract surgery and posterior chamber IOL implantation in the capsular bag were enrolled. We compared the calculation accuracy of the 8 formulas at 1 month postoperatively and performed subgroup analysis according to age or axial length (AL). Results The mean age at surgery was 34.07 +/- 24.60 months and mean AL was 21.12 +/- 1.42 mm. The mean prediction errors (PE) of eight formulas for all patients were as follows: SRK II (- 0.66), SRK/T (- 0.44), Holladay 1 (- 0.36), Hoffer Q (- 0.09), Olsen (0.71), Barrett (0.37), Holladay 2 (- 0.70), and Haigis (0.50). There was significant difference among the 8 formulas (p < 0.0001), while no significant difference of absolute PE was found among the 8 formulas in all patients (p = 0.053). Moreover, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formula was relatively accurate in 34% and 39% of eyes, respectively. While in patients older than 2 or with AL > 21 mm, Barrett and Haigis formulas were better (58% and 47% for Barrett, 52% and 53% for Haigis). Conclusion Overall, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formulas were relatively accurate, while Barrett and Haigis formulas were better in patients older than 2 or with AL > 21 mm.
引用
收藏
页码:1123 / 1131
页数:9
相关论文
共 50 条
  • [21] Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
    Zeng, Zongsheng
    Zhu, Meiyi
    Zhang, Guangbin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [22] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [23] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [24] Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry
    Yilmaz, Ibrahim Edhem
    Kimyon, Sabit
    Mete, Alper
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 3071 - 3077
  • [25] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [26] Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry
    İbrahim Edhem Yılmaz
    Sabit Kimyon
    Alper Mete
    International Ophthalmology, 2022, 42 : 3071 - 3077
  • [27] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [28] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [30] Intraocular lens power calculation in pediatric cataract surgery: A narrative review
    Wojcik-Niklewska, Bogumila
    Nocon-Bratek, Martyna
    Szala, Klaudia
    MEDICINE, 2025, 104 (14)