Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients

被引:17
|
作者
Chang, Pingjun [1 ,2 ]
Lin, Lei [1 ,2 ]
Li, Zhangliang [1 ,2 ]
Wang, Li [3 ]
Huang, Jinhai [1 ,2 ]
Zhao, Yun-e [1 ,2 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou Xueyuan Rd, Wenzhou 325102, Zhejiang, Peoples R China
[2] Minist Hlth, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
基金
中国国家自然科学基金;
关键词
Pediatric cataract; Calculation formulas; Intraocular lens power; Prediction errors; REFRACTIVE OUTCOMES; SURGICAL OUTCOMES; IMPLANTATION; CHILDREN; SURGERY; EYES;
D O I
10.1007/s00417-020-04617-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy of the eight formulas for intraocular lens (IOL) power calculation in pediatric cataract patients. Methods A retrospective study. A total of 68 eyes (68 patients) that underwent uneventful cataract surgery and posterior chamber IOL implantation in the capsular bag were enrolled. We compared the calculation accuracy of the 8 formulas at 1 month postoperatively and performed subgroup analysis according to age or axial length (AL). Results The mean age at surgery was 34.07 +/- 24.60 months and mean AL was 21.12 +/- 1.42 mm. The mean prediction errors (PE) of eight formulas for all patients were as follows: SRK II (- 0.66), SRK/T (- 0.44), Holladay 1 (- 0.36), Hoffer Q (- 0.09), Olsen (0.71), Barrett (0.37), Holladay 2 (- 0.70), and Haigis (0.50). There was significant difference among the 8 formulas (p < 0.0001), while no significant difference of absolute PE was found among the 8 formulas in all patients (p = 0.053). Moreover, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formula was relatively accurate in 34% and 39% of eyes, respectively. While in patients older than 2 or with AL > 21 mm, Barrett and Haigis formulas were better (58% and 47% for Barrett, 52% and 53% for Haigis). Conclusion Overall, in patients younger than 2 years old or with AL <= 21 mm, SRK/T formulas were relatively accurate, while Barrett and Haigis formulas were better in patients older than 2 or with AL > 21 mm.
引用
收藏
页码:1123 / 1131
页数:9
相关论文
共 50 条
  • [31] Accuracy of Intraocular Lens Power Formulas Modified for Patients with Keratoconus
    Kane, Jack X.
    Connell, Benjamin
    Yip, Harry
    McAlister, James C.
    Beckingsale, Peter
    Snibson, Grant R.
    Chan, Elsie
    OPHTHALMOLOGY, 2020, 127 (08) : 1037 - 1042
  • [32] Longitudinal changes in ocular biometry and their effect on intraocular lens power calculation accuracy in cataract patients
    Yun, Young In
    Oh, Richul
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [33] Toric intraocular lens power calculation in cataract patients with keratoconus
    Ton, Yokrat
    Barrett, Graham D.
    Kleinmann, Guy
    Levy, Adi
    Assia, Ehud I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : 1389 - 1397
  • [34] Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes
    Li, Xinxin
    Song, Chunyuan
    Wang, Yong
    Wang, Jing
    Tang, Qiongyan
    Wu, Zheming
    Zhou, Yanwen
    Sun, Juan
    Jia, Yanhong
    Lin, Zhenlin
    Li, Shaowei
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3619 - 3628
  • [35] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [36] Advancements in intraocular lens power calculation formulas
    Chung, Jinkwon
    Bu, Jennifer J.
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2022, 33 (01) : 35 - 40
  • [37] Comparative accuracy of intraocular lens power calculation formulas when targeting myopia
    Yang, Soonwon
    Park, Chanjoon
    Byun, Yong-Soo
    Chung, So-Hyang
    Kim, Hyun Seung
    HELIYON, 2024, 10 (13)
  • [38] Efficacy of corneal curvature on the accuracy of 8 intraocular lens power calculation formulas in 302 highly myopic eyes
    Mo, Er
    Feng, Ke
    Li, Qiyuan
    Xu, Jingyuan
    Cen, Jiaying
    Li, Jin
    Zhao, Yun-e
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (12): : 1195 - 1200
  • [39] Accuracy of the refractive prediction determined by intraocular lens power calculation formulas in high myopia
    Zhou, Dong
    Sun, Zhuo
    Deng, Guohua
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (04) : 484 - 489
  • [40] Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes
    Wang, Qiwei
    Jiang, Wu
    Lin, Tiao
    Wu, Xiaohang
    Lin, Haotian
    Chen, Weirong
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (04): : 356 - 363