In this work we study the estimation error of ball center cone beam projections. This problem arises in the context of cone beam system calibration. The cone beam projection of a ball is generally an ellipse. It is well known that the ellipse center is usually different from the ball center projection. We show that the centroid of the ellipse (gray level gravity center) is also different from the ball center projection, even if closer to the ball center projection than the ellipse center is. However, we numerically show that in usual applications (focal length around 1m and detector size less than 0.4m), the centroid or the ellipse center estimation are good approximations of the ball center projection. We study numerically the ball center estimation error as a function of the ball size, the noise quantity and the x-ray source (or optical center) finite size.
引用
收藏
页码:2859 / 2863
页数:5
相关论文
共 50 条
  • [41] CONE-BEAM RECONSTRUCTION BY THE USE OF RADON-TRANSFORM INTERMEDIATE FUNCTIONS
    CLACK, R
    DEFRISE, M
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (02) : 580 - 585
  • [42] CLINICAL CONE-BEAM SPECT
    BICE, AN
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (01) : 141 - 142
  • [43] CONE-BEAM PRECISION BALANCE
    STOCK, JT
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1975, (169): : 3 - 3
  • [44] CONE-BEAM TECHNOLOGY response
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2011, 142 (03): : 246 - 246
  • [45] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [46] Helical cone-beam tomography
    Turbell, H
    Danielsson, PE
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2000, 11 (01) : 91 - 100
  • [47] A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product
    Kim, S.
    Song, H.
    Samei, E.
    Yin, F.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [48] Accuracy of cone-beam computed tomography in imaging the components of the periodontal phenotype
    Schulze, Ralf
    Couso-Queiruga, Emilio
    Katsaros, Christos
    PERIODONTOLOGY 2000, 2024,
  • [49] USE OF CONE-BEAM COLLIMATION FOR MAGNIFICATION SPECT BONE IMAGING OF THE EXTREMITIES
    COOPER, JA
    MAHMOOD, MM
    SMITH, HS
    MCCANDLESS, BK
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P142 - P143
  • [50] Performance Characterization of a Cone-Beam Computed Tomography System for Musculoskeletal Imaging
    De Jean, P.
    Zbijewski, W.
    Yorkston, J.
    Packard, N.
    Yang, D.
    Senn, R.
    Machado, A.
    Carrino, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06)