Cone-Beam Imaging of Delta Functions

被引:7
|
作者
Desbat, Laurent [1 ]
Clackdoyle, Rolf [2 ,3 ]
Grezes-Besset, Louise [4 ]
Mennessier, Catherine [2 ,3 ]
Bricault, Ivan [1 ]
机构
[1] Grenoble Univ, CNRS, TIMC IMAG, UJF,UMR 5525, Grenoble, France
[2] Univ Lyon, Lab Traitement Signaux Images, Lyon, France
[3] Univ St Etienne, Lab Traitement Signaux Images, St Etienne, France
[4] Univ Lyon, CPE, Lyon, France
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
pinhole system calibration; ball center cone beam projection estimation;
D O I
10.1109/NSSMIC.2006.356473
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work we study the estimation error of ball center cone beam projections. This problem arises in the context of cone beam system calibration. The cone beam projection of a ball is generally an ellipse. It is well known that the ellipse center is usually different from the ball center projection. We show that the centroid of the ellipse (gray level gravity center) is also different from the ball center projection, even if closer to the ball center projection than the ellipse center is. However, we numerically show that in usual applications (focal length around 1m and detector size less than 0.4m), the centroid or the ellipse center estimation are good approximations of the ball center projection. We study numerically the ball center estimation error as a function of the ball size, the noise quantity and the x-ray source (or optical center) finite size.
引用
收藏
页码:2859 / 2863
页数:5
相关论文
共 50 条
  • [31] Projection extension for region of interest imaging in cone-beam CT
    Wiegert, J
    Bertram, M
    Netsch, T
    Wulff, J
    Weese, J
    Rose, G
    ACADEMIC RADIOLOGY, 2005, 12 (08) : 1010 - 1023
  • [32] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Aydin, Ulkem
    Gormez, Ozlem
    Yildirim, Derya
    ORAL RADIOLOGY, 2020, 36 (03) : 217 - 224
  • [33] TOMOGRAPHIC IMAGING OF THE DISTAL EXTREMITIES USING CONE-BEAM COLLIMATION
    COOPER, JA
    MAHMOOD, MM
    SMITH, HS
    MCCANDLESS, BK
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : 914 - 917
  • [34] Respiratory gated cone-beam CT volumetric imaging for external beam radiotherapy
    Moseley, DJ
    Hawkins, M
    Eccles, C
    Euler, C
    White, EA
    Bissonnette, J
    Dawson, LA
    Jaffray, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S27 - S28
  • [36] Dose delivered to patients for megavoltage cone-beam CT imaging
    Morin, O.
    Bellerose, J.
    Descovich, M.
    Aubin, N.
    Chen, J.
    Aubry, J.
    Chen, H.
    Pouliot, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1999 - 1999
  • [37] Task-Driven Imaging in Cone-Beam Computed Tomography
    Gang, G. J.
    Stayman, J. W.
    Ouadah, S.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [38] Cone-beam computed tomography imaging of dentoalveolar and mandibular fractures
    Ulkem Aydin
    Ozlem Gormez
    Derya Yildirim
    Oral Radiology, 2020, 36 : 217 - 224
  • [39] Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging
    Perenyi Adam
    Bella Zsolt
    Barath Zoltan
    Magyar Peter
    Nagy Katalin
    Rovo Laszlo
    ORVOSI HETILAP, 2016, 157 (02) : 52 - 58
  • [40] Optimization of helical orbit cone-beam SPECT imaging performance for brain imaging
    Vogelsang, Levon
    Krol, Andrzej
    Lipson, Edward
    Feiglin, David
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53