Multi-detector row CT colonography: Effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen

被引:40
|
作者
Taylor, SA
Halligan, S
Bartram, CI
Morgan, PR
Talbot, IC
Fry, N
Saunders, BP
Khosraviani, K
Atkin, W
机构
[1] St Marks Hosp, Dept Intestinal Imaging, Harrow HA1 3UJ, Middx, England
[2] St Marks Hosp, Dept Pathol, Harrow HA1 3UJ, Middx, England
[3] St Marks Hosp, Dept Surg, Harrow HA1 3UJ, Middx, England
[4] St Marks Hosp, Dpet Endoscopy, Harrow HA1 3UJ, Middx, England
[5] St Marks Hosp, Canc Res UK Colorectal Canc Unit, Harrow HA1 3UJ, Middx, England
[6] Gen Elect Med Syst, Slough, Berks, England
关键词
colon; CT; colon neoplasms; computer tomography (CT); technology;
D O I
10.1148/radiol.2291020561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. MATERIALS AND METHODS: A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. RESULTS: The percentage of polyps that were detected significantly increased when collimation (P = .008) and table feed (P = .03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small Polyps in the transverse segment (positioned at a 90degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P < .001). The effective radiation dose, calculated with a Monte Carlo simulation, was 1.4-10.0 mSv. CONCLUSION: Detection of small polyps (< 5 mm) with multi-detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. (C) RSNA, 2003.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [31] Multi-detector row CT: Is prospective electrocardiographic triggering improving the detection of small pulmonary tumors?
    Pauls, S
    Aschoff, AJ
    Wahl, J
    Brambs, HJ
    Fleiter, TR
    ACADEMIC RADIOLOGY, 2005, 12 (05) : 614 - 619
  • [32] Automated segmentation of urinary bladder and detection of bladder lesions in multi-detector row CT urography
    Hadjiiski, Lubomir
    Sahiner, Berkman
    Chan, Heang-Ping
    Caoili, Elaine M.
    Cohan, Richard H.
    Zhou, Chuan
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [33] Coronary artery calcification: Effect of size of field of view on multi-detector row CT measurements
    Hong, C
    Pilgram, TK
    Zhu, F
    Bae, KT
    RADIOLOGY, 2004, 233 (01) : 281 - 285
  • [34] Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume
    Goo, Jin Mo
    Kim, Kwang Gi
    Gierada, David S.
    Castro, Mario
    Bae, Kyongtae T.
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (04) : 243 - 248
  • [35] Acute massive gastrointestinal bleeding: Detection and localization with arterial phase multi-detector row helical CT
    Yoon, W
    Jeong, YY
    Shin, SS
    Lim, HS
    Song, SG
    Jang, NG
    Kim, JK
    Kang, HK
    RADIOLOGY, 2006, 239 (01) : 160 - 167
  • [36] Preoperative T and N staging of colorectal cancer: Accuracy of contrast-enhanced multi-detector row CT colonography - Initial experience
    Filippone, A
    Ambrosini, R
    Fuschi, M
    Marinelli, T
    Genovesi, D
    Bonomo, L
    RADIOLOGY, 2004, 231 (01) : 83 - 90
  • [37] Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation
    Achenbach, S
    Ropers, D
    Pohle, FK
    Raaz, D
    von Erffa, J
    Yilmaz, A
    Muschiol, G
    Daniel, WG
    EUROPEAN HEART JOURNAL, 2005, 26 (19) : 1978 - 1986
  • [38] Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose
    Hong, C
    Bae, KT
    Pilgram, TK
    Suh, J
    Bradley, D
    RADIOLOGY, 2002, 225 (03) : 901 - 906
  • [39] Optimization of multi-detector row CT urography: Effect of compression, saline administration, and prolongation of acquisition delay
    Caoili, EM
    Inampudi, P
    Cohan, RH
    Ellis, JH
    RADIOLOGY, 2005, 235 (01) : 116 - 123
  • [40] Detection of low-contrast objects: Experimental comparison of single- and multi-detector row CT with a phantom
    Verdun, FR
    Denys, A
    Valley, JF
    Schnyder, P
    Meuli, RA
    RADIOLOGY, 2002, 223 (02) : 426 - 431