Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume

被引:30
|
作者
Goo, Jin Mo
Kim, Kwang Gi
Gierada, David S.
Castro, Mario
Bae, Kyongtae T.
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[2] SNUMRC, Inst Radiat Med, Seoul 110744, South Korea
[3] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Div Pulm & Crit Care Med, Dept Internal Med, St Louis, MO 63110 USA
关键词
computed tomography (CT) multi-detector row; computed tomography (CT) quantitative; computed tomography (CT) three-dimensional computers; diagnostic aid lung; nodule;
D O I
10.3348/kjr.2006.7.4.243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Materials and Methods: Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules >= 3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired Nest. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. Results: The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1% for all nodules and for nodules >= 3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules >= 3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules >= 3 mm. Conclusion: Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [1] Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy
    Goo, JM
    Tongdee, T
    Tongdee, R
    Yeo, K
    Hildebolt, CF
    Bae, KT
    RADIOLOGY, 2005, 235 (03) : 850 - 856
  • [2] Lung cancer perfusion at multi-detector row CT: Reproducibility of whole tumor quantitative measurements
    Ng, QS
    Goh, V
    Fichte, H
    Klotz, E
    Fernie, P
    Saunders, MI
    Hoskin, PJ
    Padhani, AR
    RADIOLOGY, 2006, 239 (02) : 547 - 553
  • [3] Bronchial anatomy of left lung: a study of multi-detector row CT
    Zhao, Xinya
    Ju, Yuanrong
    Liu, Cheng
    Li, Jianfeng
    Huang, Min
    Sun, Jian
    Wang, Tao
    SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (02) : 85 - 91
  • [4] Bronchial anatomy of left lung: a study of multi-detector row CT
    Xinya Zhao
    Yuanrong Ju
    Cheng Liu
    Jianfeng Li
    Min Huang
    Jian Sun
    Tao Wang
    Surgical and Radiologic Anatomy, 2009, 31 : 85 - 91
  • [5] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Dag Wormanns
    Gerhard Kohl
    Ernst Klotz
    Anke Marheine
    Florian Beyer
    Walter Heindel
    Stefan Diederich
    European Radiology, 2004, 14 : 86 - 92
  • [6] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Wormanns, D
    Kohl, G
    Klotz, E
    Marheine, A
    Beyer, F
    Heindel, W
    Diederich, S
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 86 - 92
  • [7] CT number accuracy of simulated lung nodules imaged with a multi-detector CT scanner
    Goodsitt, M
    Chan, H
    Larson, S
    Christodoulou, E
    Kim, J
    Way, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2104 - 2104
  • [8] Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners
    Goodsitt, Mitchell M.
    Chan, Heang-Ping
    Way, Ted W.
    Larson, Sandra C.
    Christodoulou, Emmanuel G.
    Kim, Jeomsoon
    MEDICAL PHYSICS, 2006, 33 (08) : 3006 - 3017
  • [9] Multi-detector row CT and postprocessing techniques in the assessment of diffuse lung disease
    Beigelman-Aubry, C
    Hill, C
    Guibal, A
    Savatovsky, J
    Grenier, PA
    RADIOGRAPHICS, 2005, 25 (06) : 1639 - 1652
  • [10] Multi-detector row CT of hemoptysis
    Bruzzi, John F.
    Remy-Jardin, Martine
    Delhaye, Damien
    Teisseire, Antoine
    Khalil, Chadi
    Remy, Jacques
    RADIOGRAPHICS, 2006, 26 (01) : 3 - U78