Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume

被引:30
|
作者
Goo, Jin Mo
Kim, Kwang Gi
Gierada, David S.
Castro, Mario
Bae, Kyongtae T.
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[2] SNUMRC, Inst Radiat Med, Seoul 110744, South Korea
[3] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Div Pulm & Crit Care Med, Dept Internal Med, St Louis, MO 63110 USA
关键词
computed tomography (CT) multi-detector row; computed tomography (CT) quantitative; computed tomography (CT) three-dimensional computers; diagnostic aid lung; nodule;
D O I
10.3348/kjr.2006.7.4.243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Materials and Methods: Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules >= 3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired Nest. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. Results: The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1% for all nodules and for nodules >= 3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules >= 3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules >= 3 mm. Conclusion: Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [41] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [42] Virtual endoscopy of dogs using multi-detector row CT
    Yamada, Kazutaka
    Morimoto, Manabu
    Kishimoto, Miori
    Wisner, Erik R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2007, 48 (04) : 318 - 322
  • [43] Multi-detector row CT: Principles and practice for abdominal applications
    Saini, S
    RADIOLOGY, 2004, 233 (02) : 323 - 327
  • [44] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [45] Multi-detector row CT of pancreatic islet cell tumors
    Horton, Karen M.
    Hruban, Ralph H.
    Yeo, Charles
    Fishman, Elliot K.
    RADIOGRAPHICS, 2006, 26 (02) : 453 - U10
  • [46] Application of multi-detector row helical scanning to postmyelographic CT
    Tsuchiya, K
    Katase, S
    Aoki, C
    Hachiya, J
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1438 - 1443
  • [47] Recent Technologic Advances in Multi-Detector Row Cardiac CT
    Halliburton, Sandra Simon
    CARDIOLOGY CLINICS, 2009, 27 (04) : 655 - +
  • [48] Pancreatic carcinoma: Developing a protocol for multi-detector row CT
    Johnson, CD
    RADIOLOGY, 2001, 220 (01) : 3 - 4
  • [50] Multi-detector row CT imaging of blunt abdominal trauma
    Shanmuganathan, K