Online High-Flow Peptide Immunoaffinity Enrichment and Nanoflow LC-MS/MS: Assay Development for Total Salivary Pepsin/Pepsinogen

被引:73
|
作者
Neubert, Hendrik [1 ]
Gale, Jeremy [2 ]
Muirhead, David [3 ]
机构
[1] Pfizer Ltd, Pharmacokinet Dynam & Metab & Biotherapeut & Tran, Sandwich, Kent, England
[2] Pfizer Ltd, Clin Res, Sandwich, Kent, England
[3] Pfizer Ltd, Clin Assay Grp, Sandwich, Kent, England
关键词
TANDEM MASS-SPECTROMETRY; MATRIX-METALLOPROTEINASE ACTIVITY; QUANTITATIVE-ANALYSIS; PROTEIN BIOMARKERS; MAGNETIC BEADS; QUANTIFICATION; SERUM; SISCAPA; VALIDATION; URINE;
D O I
10.1373/clinchem.2010.144576
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Detection limit challenges associated with measuring low-abundance protein biomarkers can be addressed with hybrid immunoaffinity-mass spectrometric assays, such as antipeptide antibody capture followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS). Popular assay formats use magnetic bead-based immunoaffinity enrichment and nanoflow LC-MS/MS or high-flow immunoaffinity chromatography coupled online to conventional LCMS/MS. As a proof of principle, we describe a novel online immunoaffinity LC-MS/MS configuration that combines high-flow peptide immunoaffinity enrichment and nanoflow LC-MS/MS. METHODS: We configured and validated an assay for the measurement of total pepsin/pepsinogen from human saliva that uses a pepsinogen standard. Saliva was heat-inactivated to quench residual enzymatic activity and then digested with endoproteinase AspN. Online immunoaffinity enrichment using an antipeptide antibody directed against the pepsin C-terminal sequence, DRANNQVGLAPVA, was linked to nanoflow liquid chromatography and selected reaction monitoring mass spectrometry. We used the assay to measure pepsin/pepsinogen concentrations in human saliva from presumed healthy volunteers. RESULTS: Heat inactivation at 100 degrees C for 25 min stabilized the target peptide. The final assay had < 15% interassay relative error and < 15% interassay CV across a range of 4.08-2980 pmol/L human pepsinogen (0.165-120 mu g/L). Low but quantifiable signals were observed in some samples from presumed normal healthy volunteers ranging from 4.3 to 16.6 pmol/L (0.17-0.67 mu g/L) total salivary pepsin/pepsinogen. CONCLUSIONS: This assay approach provides a high-sensitivity platform for protein bioanalysis in the low picomolar range. It bears the potential to deliver additional data on the salivary occurrence of pepsin/pepsinogen with greater confidence than previously. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1413 / 1423
页数:11
相关论文
共 32 条
  • [1] Replacing immunoassays with tryptic digestion-peptide immunoaffinity enrichment and LC-MS/MS
    Becker, Jessica
    Hoofnagle, Andrew N.
    BIOANALYSIS, 2012, 4 (03) : 281 - 290
  • [2] Quantification of Amyloid-β in Plasma by Simple and Highly Sensitive Immunoaffinity Enrichment and LC-MS/MS Assay
    Iino, Takuya
    Watanabe, Shunsuke
    Yamashita, Kazuto
    Tamada, Eiya
    Hasegawa, Takehiro
    Irino, Yasuhiro
    Iwanaga, Shigeki
    Harada, Amane
    Noda, Kenta
    Suto, Kouzou
    Yoshida, Tomokazu
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (04): : 834 - 845
  • [3] Development and validation of a novel LC-MS/MS assay for C-peptide in human serum
    Owusu, Benjamin Y.
    Pflaum, Hannah
    Garner, Russell
    Foulon, North
    Laha, Thomas J.
    Hoofnagle, Andrew N.
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2021, 19 : 1 - 6
  • [4] Development and fit-for-purpose validation of a LC-MS/MS assay for fibrinogen peptide A quantitation in human plasma
    Lin, Mingxiang
    Lassman, Michael E.
    Weiner, Russell
    Laterza, Omar F.
    BIOANALYSIS, 2014, 6 (13) : 1759 - 1766
  • [5] Development of a CDC-certified total testosterone assay for adult and pediatric samples using LC-MS/MS
    Star-Weinstock, Michal
    Dey, Subhakar
    CLINICAL MASS SPECTROMETRY, 2019, 13 : 27 - 35
  • [6] Sensitive LC-MS/MS Assay for Total Testosterone Quantification on Unit Resolution and High-Resolution Instruments
    Wolken, Jill K.
    Peterson, Meghan M.
    Cao, Wenjing
    Challoner, Keith
    Jin, Zhicheng
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
  • [7] Development and validation of a high-throughput LC-MS/MS assay for routine measurement of molecular ceramides
    Kauhanen, Dimple
    Sysi-Aho, Marko
    Koistinen, Kaisa M.
    Laaksonen, Reijo
    Sinisalo, Juha
    Ekroos, Kim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (13) : 3475 - 3483
  • [8] Development of a Peptide Immunoaffinity LC-MS/MS Assay for Frataxin Transgene Protein Measurements after AAV9-FXN Treatment of the MCK Mouse Model of Friedreich Ataxia
    Farrokhi, Vahid
    Parng, Chuenlei
    Martelli, Alain
    Wayne, Stochaji
    Caiazzo, Teresa
    Lavallie, Edward
    Pregel, Marko
    Neubert, Hendrik
    MOLECULAR THERAPY, 2020, 28 (04) : 27 - 27
  • [9] Development and validation of a hybrid immunoaffinity LC-MS/MS assay for quantitation of total antibody (TAb) from an antibody drug conjugate (ADC) PYX-201 in human plasma
    Yin, Feng
    Adhikari, Diana
    Peay, Marlking
    Cortes, Diego
    Garada, Mohammed
    Ma, Eric
    Lebarbenchon, Diane
    Mylott, William
    Dyszel, Mike
    Harriman, Shawn
    Pinkas, Jan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1228
  • [10] High-throughput analysis of underivatized methylmalonic acid and total homocysteine in serum and urine by LC-MS/MS assay
    Ma, X.
    CLINICA CHIMICA ACTA, 2022, 530 : S18 - S19