Online High-Flow Peptide Immunoaffinity Enrichment and Nanoflow LC-MS/MS: Assay Development for Total Salivary Pepsin/Pepsinogen

被引:73
|
作者
Neubert, Hendrik [1 ]
Gale, Jeremy [2 ]
Muirhead, David [3 ]
机构
[1] Pfizer Ltd, Pharmacokinet Dynam & Metab & Biotherapeut & Tran, Sandwich, Kent, England
[2] Pfizer Ltd, Clin Res, Sandwich, Kent, England
[3] Pfizer Ltd, Clin Assay Grp, Sandwich, Kent, England
关键词
TANDEM MASS-SPECTROMETRY; MATRIX-METALLOPROTEINASE ACTIVITY; QUANTITATIVE-ANALYSIS; PROTEIN BIOMARKERS; MAGNETIC BEADS; QUANTIFICATION; SERUM; SISCAPA; VALIDATION; URINE;
D O I
10.1373/clinchem.2010.144576
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Detection limit challenges associated with measuring low-abundance protein biomarkers can be addressed with hybrid immunoaffinity-mass spectrometric assays, such as antipeptide antibody capture followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS). Popular assay formats use magnetic bead-based immunoaffinity enrichment and nanoflow LC-MS/MS or high-flow immunoaffinity chromatography coupled online to conventional LCMS/MS. As a proof of principle, we describe a novel online immunoaffinity LC-MS/MS configuration that combines high-flow peptide immunoaffinity enrichment and nanoflow LC-MS/MS. METHODS: We configured and validated an assay for the measurement of total pepsin/pepsinogen from human saliva that uses a pepsinogen standard. Saliva was heat-inactivated to quench residual enzymatic activity and then digested with endoproteinase AspN. Online immunoaffinity enrichment using an antipeptide antibody directed against the pepsin C-terminal sequence, DRANNQVGLAPVA, was linked to nanoflow liquid chromatography and selected reaction monitoring mass spectrometry. We used the assay to measure pepsin/pepsinogen concentrations in human saliva from presumed healthy volunteers. RESULTS: Heat inactivation at 100 degrees C for 25 min stabilized the target peptide. The final assay had < 15% interassay relative error and < 15% interassay CV across a range of 4.08-2980 pmol/L human pepsinogen (0.165-120 mu g/L). Low but quantifiable signals were observed in some samples from presumed normal healthy volunteers ranging from 4.3 to 16.6 pmol/L (0.17-0.67 mu g/L) total salivary pepsin/pepsinogen. CONCLUSIONS: This assay approach provides a high-sensitivity platform for protein bioanalysis in the low picomolar range. It bears the potential to deliver additional data on the salivary occurrence of pepsin/pepsinogen with greater confidence than previously. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:1413 / 1423
页数:11
相关论文
共 32 条
  • [31] Development and validation of an ultra-high performance LC-MS/MS assay for intracellular SN-38 in human solid tumour cell lines: Comparison with a validated HPLC-fluorescence method
    Ghazaly, Essam
    Perry, Jackie
    Kitromilidou, Christiana
    Powles, Thomas
    Joel, Simon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 969 : 213 - 218
  • [32] High-Throughput, Sensitive LC-MS Quantification of Biotherapeutics and Biomarkers Using Antibody-Free, Peptide-Level, Multiple-Mechanism Enrichment via Strategic Regulation of pH and Ionic and Solvent Strengths
    An, Bo
    Zhang, Ming
    Pu, Jie
    Shen, Shichen
    Qu, Yang
    Chen, Yuan-Ju
    Huo, Shihan
    Wang, Xue
    Polli, Joseph Ryan
    Balthasar, Joseph P.
    Herzog, Denis
    Ferrari, Luca
    Staack, Roland F.
    Richter, Wolfgang F.
    Otteneder, Michael B.
    Benincosa, Lisa J.
    Zhou, Shaolian
    Vazvaei, Faye
    Qu, Jun