A thermal network model for hydrocarbon heat pump systems: A coupling analysis of configuration, working condition, and refrigeration distribution

被引:8
|
作者
Liang, Jierong [1 ,2 ]
Zhu, Tingting [2 ,3 ]
Sun, Li [4 ]
Wang, Hao [5 ]
Li, Tingxun [1 ]
机构
[1] Sun Yat Sen Univ, Sch Intelligent Syst Engn, West Xingan Rd 135, Guangzhou 510275, Peoples R China
[2] Tech Univ Denmark, Dept Civil & Mech Engn, Sect Thermal Energy, Nils Koppels, DK-2800 Lyngby, Denmark
[3] Univ Twente, Fac Engn Technol ET, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[4] Hohai Univ, Coll Mech & Elect Engn, Changzhou 213022, Peoples R China
[5] Guangdong Shenling Environm Syst Co Ltd, Xinglong 10th Rd 8, Foshan 528313, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump model; Resistance-capacitance network; Hydrocarbon; Charge reduction; Refrigerant distribution; AIR-CONDITIONER; PRESSURE-DROP; 2-PHASE FLOW; MASS-DISTRIBUTION; FRICTION CHARACTERISTICS; CHARGE OPTIMIZATION; GENERAL CORRELATION; HORIZONTAL TUBES; RISK-ASSESSMENT; SMOOTH TUBES;
D O I
10.1016/j.enconman.2022.115908
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ambition of zero emission neighborhood has been set out to operate the building components with zero life cycle greenhouse gas emissions. Hydrocarbon heat pumps as the building components with nearly zero greenhouse gas emissions are faced with the problem of simultaneously reducing refrigerant charges and maintaining competitive capacities. These must be resolved by formulating an effective modeling tool for detailed design and optimization. To develop a resistance-capacitance network model, interdisciplinary knowledge (including graph theory, heat and mass transfer, local moving boundary modeling, and algebraic multigrid) is integrated. The model simultaneously considers heat exchanger circuitries with a high detail level and component behaviors at a holistic system level. Based on experimental validation, the model's error is similar to 10%. In an R290 heat pump case study, the coupling mechanism of the system's configuration, working conditions, and refrigerant distribution are analyzed. Results indicate that the refrigerant charge can be reduced by 11.6% at the expense of a 4.2% reduction in the coefficient of performance, by varying the compressor displacement alone. In response to the variation in the system's refrigerant, 46.8%, 7.85%, and 44.2% of the total amount of refrigerants are allocated to the condenser, evaporator, and compressor, respectively. The distribution of the refrigerant quality in the heat exchanger is also visualized to indicate the direction of refrigerant reduction.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Current status of natural working fluids in refrigeration, a/c, and heat pump systems
    Kruse, H
    APPLICATIONS FOR NATURAL REFRIGERANTS, 1996, : 49 - 64
  • [2] Novel molecules as working fluids for refrigeration, heat pump and organic Rankine cycle systems
    Gimenez-Prades, P.
    Navarro-Esbri, J.
    Arpagaus, C.
    Fernandez-Moreno, A.
    Mota-Babiloni, A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 167
  • [3] ANALYTICAL STUDIES ON THE PERFORMANCE OF CASCADED REFRIGERATION HEAT-PUMP SYSTEMS WITH DIFFERENT WORKING FLUID COMBINATIONS
    MURTHY, SS
    MURTHY, MVK
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1982, 2 (03): : 233 - 245
  • [4] Characteristics analysis of the photovoltaic thermal heat pump system on refrigeration mode: An experimental investigation
    Liang, Ruobing
    Zhou, Chao
    Zhang, Jili
    Chen, Jianquan
    Riaz, Ahmad
    RENEWABLE ENERGY, 2020, 146 : 2450 - 2461
  • [5] Thermal economic analysis on LiBr refrigeration -heat pump system applied in CCHP system
    Zhang, CuiZhen
    Yang, Mo
    Lu, Mei
    Zhu, Jiaxian
    Xu, Wendong
    2012 INTERNATIONAL CONFERENCE ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING (ICMPBE2012), 2012, 33 : 672 - 677
  • [6] THERMAL CHARACTERISTICS OF COMBINED COMPRESSOR - EJECTOR REFRIGERATION/HEAT PUMP SYSTEMS FOR HVAC&R
    Gjerasimovski, Aleksandar
    Sharevska, Maja
    Gjerasimovska, Natasha
    Sharevska, Monika
    Filkoski, Risto V.
    THERMAL SCIENCE, 2024, 28 (2C): : 1577 - 1587
  • [7] Design and Heat Transfer Analysis of a New Psychrometric Environmental Chamber for Heat Pump and Refrigeration Systems Testing
    Cremaschi, Lorenzo
    Lee, Edwin
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 2, 2008, 114 : 619 - 631
  • [8] Thermal stability of trifluoroiodomethane (R13I1) as an environmentally friendly working fluid for refrigeration and heat pump systems: Investigations and improvement strategies
    Chen, Yubo
    Yang, Zhao
    Hu, Yansong
    Zhang, Yong
    He, Hongxia
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [9] Model-based Analysis of the Performance and the Environmental Impact of Solar Thermal and Heat Pump Systems
    Jonas, Danny
    Frey, Georg
    2018 9TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2018,
  • [10] Composition adjustment study of refrigeration and heat pump systems using CO2-based mixture as the working fluid
    Sun, Jing
    Shi, Lingfeng
    Sun, Xiaocun
    Lu, Bowen
    Tian, Hua
    Yao, Yu
    Zhang, Meiyan
    Shu, Gequn
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (11) : 2597 - 2611