THERMAL CHARACTERISTICS OF COMBINED COMPRESSOR - EJECTOR REFRIGERATION/HEAT PUMP SYSTEMS FOR HVAC&R

被引:0
|
作者
Gjerasimovski, Aleksandar [1 ]
Sharevska, Maja [1 ,2 ]
Gjerasimovska, Natasha [3 ]
Sharevska, Monika [1 ]
Filkoski, Risto V. [1 ]
机构
[1] Ss Cyril & Methodius Univ, Fac Mech Engn, Skopje, North Macedonia
[2] Univ Twente, Fac Engn Technol ET, Thermal Engn TE, Enschede, Netherlands
[3] Macedonian Minist Econ, Dept Renewable Energy, Energy Sect, Skopje, North Macedonia
来源
THERMAL SCIENCE | 2024年 / 28卷 / 2C期
关键词
energy efficiency; compressor; ejector; thermocompression; HVAC&R; refrigeration; heat pump; HEAT; OPTIMIZATION; CYCLE;
D O I
10.2298/TSCI230513182G
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal characteristics of combined compressor - ejector refrigeration/heat pump systems applied in heating, ventilation, air conditioning and refrigeration (HVAC&R) of buildings are investigated. An original model for estimation of the thermal characteristics of the combined cycles is developed, to determine the influence of the evaporation, interstage, condensation, and generating temperature conditions on mechanical and thermal COP of the combined system, and to optimize the thermal parameters of the cycle. Results are presented for different temperature conditions, with R134a as a suitable refrigerant. A comparison between the thermal characteristics of the simple mechanical vapor compression cycle, the simple ejector thermocompression cycle, and the combined compressor - ejector refrigeration/heat pump cycle is given. The benefits of implementation of combined compressor - ejector refrigeration/heat pump cycles in HVAC&R systems are discussed. The temperature lift or temperature difference between condensing temperature and interstage temperature significantly influences the thermal (ejector) COP. If temperature lift is between 10 K and 20 K, high values of thermal COP can be achieved (0.5-1.0, for generating temperature equal to 80 degrees C; 1.0-1.8, for generating temperature equal to 120 degrees C). If temperature lift is between 30 K and 40 K, very low values of COPth can be obtained (0.05-0.3). High values of mechanical COP can be achieved (24.8-6.9), for compressor stage temperature lift 10-30 K.
引用
收藏
页码:1577 / 1587
页数:11
相关论文
共 50 条
  • [1] Smarter systems on HVAC&R horizon
    不详
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1996, 38 (04): : 23 - 24
  • [2] Water treatment for HVAC&R systems
    Boffardi, BP
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 52 - 56
  • [3] Application of electric power in HVAC&R systems
    Flaniken, BL
    [J]. ASHRAE JOURNAL, 1999, 41 (01) : 37 - 40
  • [4] Special Issue: "Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems"
    Yang, Kai-Shing
    Shyu, Jin-Cherng
    Lee, Ming-Tsang
    [J]. PROCESSES, 2022, 10 (07)
  • [5] HVAC&R Systems for Mango Pulp Processing
    Mamoru, Amey
    [J]. ASHRAE JOURNAL, 2016, 58 (09) : 22 - +
  • [6] Research records and optimizing HVAC&R systems
    Coker, WR
    [J]. ASHRAE JOURNAL, 1996, 38 (10) : 6 - 6
  • [7] Air supply systems for HVAC&R controls
    Bentsen, LJ
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1997, : 44 - 46
  • [8] A review on polymer heat exchangers for HVAC&R applications
    T'Joen, C.
    Park, Y.
    Wang, Q.
    Sommers, A.
    Han, X.
    Jacobi, A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 763 - 779
  • [9] A novel theory of PI control for HVAC&R systems
    Krakow, KI
    Hussein, GM
    Lin, S
    [J]. TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 1998, 22 (02) : 167 - 192
  • [10] Progress in ejector-expansion vapor compression refrigeration and heat pump systems
    Zhang, Zhenying
    Feng, Xu
    Tian, Dingzhu
    Yang, Jianjun
    Chang, Li
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 207