A self-contained and integrated microfluidic nano-detection system for the biosensing and analysis of molecular interactions

被引:7
|
作者
Xie, Xinwu [1 ,2 ]
Ma, Jinbiao [3 ,4 ]
Wang, Hao [1 ,5 ]
Cheng, Zhen [6 ]
Li, Tie [7 ,8 ]
Chen, Shixing [7 ,8 ]
Du, Yaohua [1 ,2 ]
Wu, Jianguo [1 ,5 ]
Wang, Can [3 ,4 ]
Xu, Xinxi [1 ,2 ]
机构
[1] Acad Mil Sci, Inst Systemat Engn, Dept Med Support Technol, Tianjin 300161, Peoples R China
[2] Natl Bioprotect Engn Ctr, Tianjin 300161, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[5] Tianjin Univ Sci & Technol, Sch Elect Informat & Automat, Tianjin 300222, Peoples R China
[6] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[7] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
[8] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
关键词
FIELD-EFFECT TRANSISTOR; SILICON; NANOWIRES;
D O I
10.1039/d1lc01056e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R-2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL(-1). Furthermore, the process of the binding-dissociation of antibody-protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.
引用
收藏
页码:1702 / 1713
页数:13
相关论文
共 50 条
  • [31] Analysis of pairwise cell interactions using an integrated dielectrophoretic-microfluidic system
    Yin, Zhizhong
    Noren, David
    Wang, C. Joanne
    Hang, Rob
    Levchenko, Andre
    [J]. MOLECULAR SYSTEMS BIOLOGY, 2008, 4
  • [32] An Integrated Microfluidic Biosensing System Based on a Versatile Valve and Recombinase Polymerase Amplification for Rapid and Sensitive Detection of Salmonella typhimurium
    Jin, Yan
    Wang, Jingyi
    Wang, Zhiqiang
    Xiong, Peng
    Cheng, Jianing
    Xu, Tongyu
    [J]. BIOSENSORS-BASEL, 2023, 13 (08):
  • [33] A microfluidic system with integrated molecular imprinting polymer films for surface plasmon resonance detection
    Huang, Shih-Chiang
    Lee, Gwo-Bin
    Chien, Fan-Ching
    Chen, Shean-Jen
    Chen, Wen-Janq
    Yang, Ming-Chang
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2006, 16 (07) : 1251 - 1257
  • [34] A SELF-CONTAINED PORTABLE POLYMERASE-CHAIN-REACTION SYSTEM INTEGRATED WITH ELECTROMAGNETIC MINI-ACTUATORS FOR BI-DIRECTIONAL FLUID TRANSPORT
    Chia, B. T.
    Yang, S. -A.
    Cheng, M. -Y.
    Lin, C. -W.
    Yang, Y. -J.
    [J]. JOURNAL OF MECHANICS, 2011, 27 (03) : 357 - 364
  • [35] Mobile lab: A novel pathogen assay using the nucleic acid automatic assay system assisted by a self-contained microfluidic cassette and chitosan decorating magnetic particles
    Yang, Ke
    Zhou, Jiujian
    Zhao, Jun
    Liu, Lijuan
    Hua, Changyi
    Hong, Chenggang
    Wang, Minglong
    Hu, Anzhong
    Zhang, Weilong
    Cui, Junsheng
    Zhu, Cancan
    Deng, Guoqing
    Liu, Yong
    Zhu, Ling
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 419
  • [36] Detection and quantification of specific bacterial populations using PNA molecular beacons in an integrated microfluidic system
    Xi, CW
    Raskin, L
    Boppart, SA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U809 - U809
  • [37] Multi-sensor fusion for biomechanical analysis: evaluation of dynamic interactions between self-contained breathing apparatus and firefighter using computational methods
    Xie, Bing
    Zhang, Junxia
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [38] Integrated Microfluidic System with Chemiluminescence Detection for Single Cell Analysis after Intracellular Labeling
    Zhao, Shulin
    Li, Xiangtang
    Liu, Yi-Ming
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3873 - 3878
  • [39] Integration of Power-Free and Self-Contained Microfluidic Chip with Fiber Optic Particle Plasmon Resonance Aptasensor for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein
    Chang, Ting-Chou
    Sun, Aileen Y.
    Huang, Yu-Chung
    Wang, Chih-Hui
    Wang, Shau-Chun
    Chau, Lai-Kwan
    [J]. BIOSENSORS-BASEL, 2022, 12 (10):
  • [40] Proteome-transcriptome alignment of molecular portraits achieved by self-contained gene set analysis: Consensus colon cancer subtypes case study
    Glazko, Galina
    Zybailov, Boris
    Emmert-Streib, Frank
    Baranova, Ancha
    Rahmatallah, Yasir
    [J]. PLOS ONE, 2019, 14 (08):