A self-contained and integrated microfluidic nano-detection system for the biosensing and analysis of molecular interactions

被引:7
|
作者
Xie, Xinwu [1 ,2 ]
Ma, Jinbiao [3 ,4 ]
Wang, Hao [1 ,5 ]
Cheng, Zhen [6 ]
Li, Tie [7 ,8 ]
Chen, Shixing [7 ,8 ]
Du, Yaohua [1 ,2 ]
Wu, Jianguo [1 ,5 ]
Wang, Can [3 ,4 ]
Xu, Xinxi [1 ,2 ]
机构
[1] Acad Mil Sci, Inst Systemat Engn, Dept Med Support Technol, Tianjin 300161, Peoples R China
[2] Natl Bioprotect Engn Ctr, Tianjin 300161, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[5] Tianjin Univ Sci & Technol, Sch Elect Informat & Automat, Tianjin 300222, Peoples R China
[6] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[7] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
[8] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
关键词
FIELD-EFFECT TRANSISTOR; SILICON; NANOWIRES;
D O I
10.1039/d1lc01056e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R-2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL(-1). Furthermore, the process of the binding-dissociation of antibody-protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.
引用
收藏
页码:1702 / 1713
页数:13
相关论文
共 50 条
  • [21] METDS - A Self-contained, Context-Based Detection System for Evil Twin Access Points
    Szongott, Christian
    Brenner, Michael
    Smith, Matthew
    [J]. FINANCIAL CRYPTOGRAPHY AND DATA SECURITY (FC 2015), 2015, 8975 : 370 - 386
  • [22] Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection
    Liu, RH
    Yang, JN
    Lenigk, R
    Bonanno, J
    Grodzinski, P
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (07) : 1824 - 1831
  • [23] A Novel Zero Velocity Interval Detection Algorithm for Self-Contained Pedestrian Navigation System with Inertial Sensors
    Tian, Xiaochun
    Chen, Jiabin
    Han, Yongqiang
    Shang, Jianyu
    Li, Nan
    [J]. SENSORS, 2016, 16 (10)
  • [24] Self-contained Diffuse Optical Imaging System for Real-Time Detection and Localization of Vascular Occlusions
    Pollonini, Luca
    Forseth, Kiefer J.
    Dacso, Clifford C.
    Parazynski, Scott E.
    Friedman, Jeffrey D.
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5884 - 5887
  • [25] A self-contained polymeric 2-DE chip system 2 for rapid and easy analysis
    Usui, Keisuke
    Hiratsuka, Atsunori
    Shiseki, Kisho
    Maruo, Yuji
    Matsushima, Toshiyuki
    Takahashi, Katsuyoshi
    Unuma, Yutaka
    Sakairi, Koji
    Namatame, Ichiji
    Ogawa, Yasuhiro
    Yokoyama, Kenji
    [J]. ELECTROPHORESIS, 2006, 27 (18) : 3635 - 3642
  • [26] Instrument-free, CRISPR-based diagnostics of SARS-CoV-2 using self-contained microfluidic system
    Li, Ziyue
    Ding, Xiong
    Yin, Kun
    Avery, Lori
    Ballesteros, Enrique
    Liu, Changchun
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 199
  • [27] GPSPiChain-Blockchain and AI based Self-Contained Anomaly Detection Family Security System in Smart Home
    Ali Raza
    Lachlan Hardy
    Erin Roehrer
    Soonja Yeom
    Byeong Ho Kang
    [J]. Journal of Systems Science and Systems Engineering, 2021, 30 : 433 - 449
  • [28] GPSPiChain-Blockchain and AI based Self-Contained Anomaly Detection Family Security System in Smart Home
    Raza, Ali
    Hardy, Lachlan
    Roehrer, Erin
    Yeom, Soonja
    Kang, Byeong Ho
    [J]. JOURNAL OF SYSTEMS SCIENCE AND SYSTEMS ENGINEERING, 2021, 30 (04) : 433 - 449
  • [29] Self-Contained Reference Sensors to Reduce Nuisance Alarm Rate in φ-OTDR-Based Fence Intrusion Detection System
    Zhang, Hailiang
    Dong, Hui
    Hu, Dora Juan Juan
    Ng, Jun Hong
    [J]. OPTICS, 2023, 4 (02): : 330 - 339
  • [30] Implications of Self-Contained Radiance Bias Correction for Data Assimilation within the Hurricane Analysis and Forecasting System (HAFS)
    Knisely, Joseph
    Poterjoy, Jonathan
    [J]. WEATHER AND FORECASTING, 2023, 38 (09) : 1719 - 1738