A self-contained and integrated microfluidic nano-detection system for the biosensing and analysis of molecular interactions

被引:7
|
作者
Xie, Xinwu [1 ,2 ]
Ma, Jinbiao [3 ,4 ]
Wang, Hao [1 ,5 ]
Cheng, Zhen [6 ]
Li, Tie [7 ,8 ]
Chen, Shixing [7 ,8 ]
Du, Yaohua [1 ,2 ]
Wu, Jianguo [1 ,5 ]
Wang, Can [3 ,4 ]
Xu, Xinxi [1 ,2 ]
机构
[1] Acad Mil Sci, Inst Systemat Engn, Dept Med Support Technol, Tianjin 300161, Peoples R China
[2] Natl Bioprotect Engn Ctr, Tianjin 300161, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[5] Tianjin Univ Sci & Technol, Sch Elect Informat & Automat, Tianjin 300222, Peoples R China
[6] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[7] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
[8] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
关键词
FIELD-EFFECT TRANSISTOR; SILICON; NANOWIRES;
D O I
10.1039/d1lc01056e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R-2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL(-1). Furthermore, the process of the binding-dissociation of antibody-protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.
引用
收藏
页码:1702 / 1713
页数:13
相关论文
共 50 条
  • [11] A self-contained, programmable microfluidic cell culture system with real-time microscopy access
    Peder Skafte-Pedersen
    Mette Hemmingsen
    David Sabourin
    Felician Stefan Blaga
    Henrik Bruus
    Martin Dufva
    Biomedical Microdevices, 2012, 14 : 385 - 399
  • [12] A self-contained, programmable microfluidic cell culture system with real-time microscopy access
    Skafte-Pedersen, Peder
    Hemmingsen, Mette
    Sabourin, David
    Blaga, Felician Stefan
    Bruus, Henrik
    Dufva, Martin
    BIOMEDICAL MICRODEVICES, 2012, 14 (02) : 385 - 399
  • [13] ANALYSIS AND SYNTHESIS OF THE DYNAMICS OF A SELF-CONTAINED SOLAR TRACKING SYSTEM.
    Baz, A.
    Sabry, A.
    Mobarak, A.
    Morcos, S.
    1600, (16): : 2 - 3
  • [14] Self-contained local broadband seismogeodetic early warning system: Detection and location
    Goldberg, D. E.
    Bock, Y.
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2017, 122 (04) : 3197 - 3220
  • [15] A self-contained microfluidic in-gel loop-mediated isothermal amplification for multiplexed pathogen detection
    Chen, Chen
    Liu, Pian
    Zhao, Xing
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 1 - 8
  • [16] Design and Analysis of a Persistent, Efficient, and Self-Contained WSN Data Collection System
    Zhang, Wei
    Chang, Jianfei
    Xiao, Fengjun
    Hu, Yuwei
    Xiong, Neal N.
    IEEE ACCESS, 2019, 7 : 1068 - 1083
  • [17] Development of a self-contained device for rapid detection of volatile impurities in the oil system of a turbine
    Starostin A.A.
    Shangin V.V.
    Bukhman V.G.
    Volosnikov D.V.
    Skripov P.V.
    Thermal Engineering, 2016, 63 (8) : 544 - 550
  • [18] Design and Development of a Self-contained and Non-Invasive Integrated System for Electricity Monitoring Applications
    Zarabi, Sid
    Fernandes, Egon
    Rua, Isabel
    Salehian, Armaghan
    Debeda, Helene
    Nairn, David
    Wei, Lan
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2017, : 1125 - 1128
  • [19] Leak Detection for Self-Contained Fluid-Filled Cables using Regression Analysis
    Hao, L.
    Lewin, P. L.
    Swingler, S. G.
    Bradley, C.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [20] ENERGY ANALYSIS OF A WATER-LOOP SELF-CONTAINED SYSTEM VS A MULTIPLEX SUPERMARKET
    Bagarella, G.
    Lazzarin, R.
    Noro, M.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 11 - 19