A self-contained and integrated microfluidic nano-detection system for the biosensing and analysis of molecular interactions

被引:7
|
作者
Xie, Xinwu [1 ,2 ]
Ma, Jinbiao [3 ,4 ]
Wang, Hao [1 ,5 ]
Cheng, Zhen [6 ]
Li, Tie [7 ,8 ]
Chen, Shixing [7 ,8 ]
Du, Yaohua [1 ,2 ]
Wu, Jianguo [1 ,5 ]
Wang, Can [3 ,4 ]
Xu, Xinxi [1 ,2 ]
机构
[1] Acad Mil Sci, Inst Systemat Engn, Dept Med Support Technol, Tianjin 300161, Peoples R China
[2] Natl Bioprotect Engn Ctr, Tianjin 300161, Peoples R China
[3] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[5] Tianjin Univ Sci & Technol, Sch Elect Informat & Automat, Tianjin 300222, Peoples R China
[6] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[7] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
[8] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
关键词
FIELD-EFFECT TRANSISTOR; SILICON; NANOWIRES;
D O I
10.1039/d1lc01056e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional detection methods have shortcomings such as time-consumption and requirement of large instruments, which cannot meet the demands for on-site detection or analysis. Silicon nanowire-field-effect transistor (SiNW-FET) biosensors have the advantages of high speed, high sensitivity, strong specificity, and ease of integration. However, SiNW-FET biosensors also have some demerits: they are too sensitive, environmental factors such as light, temperature, and pH easily cause interference, and their performance uniformity needs to be calibrated in advance. In this work, we constructed a self-contained and integrated microfluidic nano-detection system containing a SiNW-FET biosensor for bio-detection and analysis. All analysis processes including liquid sample delivery, optical modulation, constant temperature control, signal amplification and data acquisition, and result display were automatically performed. In series tests including light-guided ones by analyzing various types of samples with an automatic sample injection mode, the system shows good stability and robustness. Its signal accuracy was verified using a commercial high-precision ammeter (R-2 = 0.9988), too. The feasibility of the system for bio-detection was verified using simulant samples of the typical microorganism Mycobacterium tuberculosis with a limit of detection of 1.0 fg mL(-1). Furthermore, the process of the binding-dissociation of antibody-protein pairs was analyzed using the system, demonstrating the potential for molecular interaction analysis. This system is highly integrated, small in size, and easy to carry, which will be developed into a portable device for on-site bio-detection and analysis of molecular interactions to enable environmental testing, medical research, food and agricultural safety, military medicine, etc.
引用
收藏
页码:1702 / 1713
页数:13
相关论文
共 50 条
  • [1] An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids
    Chen, Dafeng
    Mauk, Michael
    Qiu, Xianbo
    Liu, Changchun
    Kim, Jitae
    Ramprasad, Sudhir
    Ongagna, Serge
    Abrams, William R.
    Malamud, Daniel
    Corstjens, Paul L. A. M.
    Bau, Haim H.
    [J]. BIOMEDICAL MICRODEVICES, 2010, 12 (04) : 705 - 719
  • [2] An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids
    Dafeng Chen
    Michael Mauk
    Xianbo Qiu
    Changchun Liu
    Jitae Kim
    Sudhir Ramprasad
    Serge Ongagna
    William R. Abrams
    Daniel Malamud
    Paul L. A. M. Corstjens
    Haim H. Bau
    [J]. Biomedical Microdevices, 2010, 12 : 705 - 719
  • [3] A self-contained microfluidic cell culture system
    Zhang, Baoyue
    Kim, Min-Cheol
    Thorsen, Todd
    Wang, Zhanhui
    [J]. BIOMEDICAL MICRODEVICES, 2009, 11 (06) : 1233 - 1237
  • [4] A self-contained microfluidic cell culture system
    Baoyue Zhang
    Min-Cheol Kim
    Todd Thorsen
    Zhanhui Wang
    [J]. Biomedical Microdevices, 2009, 11 : 1233 - 1237
  • [5] Local drug delivery with a self-contained, programmable, microfluidic system
    Fiering, J.
    Mescher, M. J.
    Swan, E. E. Leary
    Holmboe, M. E.
    Murphy, B. A.
    Chen, Z.
    Peppi, M.
    Sewell, W. F.
    McKenna, M. J.
    Kujawa, S. G.
    Borenstein, J. T.
    [J]. BIOMEDICAL MICRODEVICES, 2009, 11 (03) : 571 - 578
  • [6] A self-contained microfluidic cell sorting system for HIV diagnosis
    Sun, Y
    Liu, AQ
    Yap, PH
    Ayi, TC
    [J]. Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 1708 - 1711
  • [7] Local drug delivery with a self-contained, programmable, microfluidic system
    J. Fiering
    M. J. Mescher
    E. E. Leary Swan
    M. E. Holmboe
    B. A. Murphy
    Z. Chen
    M. Peppi
    W. F. Sewell
    M. J. McKenna
    S. G. Kujawa
    J. T. Borenstein
    [J]. Biomedical Microdevices, 2009, 11 : 571 - 578
  • [8] Nucleic acid extraction, amplification, and detection in a integrated, self-contained system.
    Beard, SE
    Gerdes, J
    Kozwich, D
    Marmaro, J
    Roehl, C
    Woronoff, S
    [J]. AMERICAN JOURNAL OF HUMAN GENETICS, 1999, 65 (04) : A57 - A57
  • [9] A SELF-CONTAINED MICROFLUIDIC CASSETTE FOR THE DETECTION OF NUCLEIC ACIDS AT THE POINT-OF-CARE
    Chen, Dafeng
    Qiu, Xianbo
    Mauk, Michael
    Bau, Haim H.
    [J]. NEMB2010: PROCEEDINGS OF THE ASME FIRST GLOBAL CONGRESS ON NANOENGINEERING FOR MEDICINE AND BIOLOGY - 2010, 2010, : 149 - 150
  • [10] A self-contained and fully integrated fluidic cassette system for multiplex nucleic acid detection of bacteriuria
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    [J]. LAB ON A CHIP, 2020, 20 (02) : 384 - 393