Personalized Anatomic Eye Model From T1-Weighted Volume Interpolated Gradient Echo Magnetic Resonance Imaging of Patients With Uveal Melanoma

被引:13
|
作者
Nguyen, Huu-Giao [1 ,2 ,3 ,4 ]
Sznitman, Raphael [2 ]
Maeder, Philippe [3 ]
Schalenbourg, Ann [6 ]
Peroni, Marta [1 ]
Hrbacek, Jan [1 ]
Weber, Damien C. [1 ]
Pica, Alessia [1 ]
Cuadra, Meritxell Bach [3 ,4 ,5 ]
机构
[1] Paul Scherrer Inst, ETH Domain, Proton Therapy Ctr, Villigen, Switzerland
[2] Univ Bern, ARTORG Ctr, Ophthalm Technol Lab, Bern, Switzerland
[3] Lausanne Univ Hosp, Radiol Dept, Lausanne, Switzerland
[4] Univ Lausanne, Ctr Imagerie BioMed, Med Image Anal Lab, Lausanne, Switzerland
[5] Ecole Polytech Fed Lausanne, Signal Proc Lab, Lausanne, Switzerland
[6] Univ Lausanne, Adult Ocular Oncol Unit, Jules Gonin Eye Hosp, FAA,Dept Ophthalmol, Lausanne, Switzerland
关键词
PROTON-BEAM RADIOTHERAPY; THIN-SECTION MR; AUTOMATIC SEGMENTATION; SPACE;
D O I
10.1016/j.ijrobp.2018.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We present a 3-dimensional patient-specific eye model from magnetic resonance imaging (MRI) for proton therapy treatment planning of uveal melanoma (UM). During MRI acquisition of UM patients, the point fixation can be difficult and, together with physiological blinking, can introduce motion artifacts in the images, thus challenging the model creation. Furthermore, the unclear boundary of the small objects (eg, lens, optic nerve) near the muscle or of the tumors with hemorrhage and tantalum clips can limit model accuracy. Methods and Materials: A dataset of 37 subjects, including 30 healthy eyes of volunteers and 7 eyes of UM patients, was investigated. In our previous work, active shape model was successfully applied to retinoblastoma eye segmentation in T1-weighted 3T MRI. Here, we evaluate this method in a more challenging setting, based on 1.5T MRI acquisition and different datasets of awake adult eyes with UM. The lens and cornea together with the sclera, vitreous humor, and optic nerve were automatically segmented and validated against manual delineations of a senior ocular radiation oncologist, in terms of the Dice similarity coefficient and Hausdorff distance. Results: Leave-one-out cross validation (mixing both volunteers and UM patients) yielded median Dice similarity coefficient values (respective of Hausdorff distance) of 94.5% (1.64 mm) for the sclera, 92.2% (1.73 mm) for the vitreous humor, 88.3% (1.09 mm) for the lens, and 81.9% (1.86 mm) for the optic nerve. The average computation time for an eye was 10 seconds. Conclusions: To our knowledge, our work is the first attempt to automatically segment adult eyes, including patients with UM. Our results show that automated active shape model segmentation can succeed in the presence of motion, tumors, and tantalum clips. These results are promising for inclusion in clinical practice. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [41] Differentiating Components of Cerebral Arteriovenous Malformations Using T1-Weighted Gradient Recall Echo MR Imaging
    Wu, E-H.
    Wong, H-F.
    Toh, C-H.
    Ng, S-H.
    Wu, Y-M.
    Wong, A. M.
    NEURORADIOLOGY JOURNAL, 2010, 23 (03): : 279 - 283
  • [42] Cerebral air emboli on T2-weighted gradient-echo magnetic resonance imaging
    Jeon, Sang-Beom
    Kang, Dong-Wha
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2007, 78 (08): : 871 - 871
  • [43] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [44] The advance in T2/T1-weighted cardiac magnetic resonance coronary plaque imaging
    Taniguchi Yasuyo
    Takeshi Ishimoto
    Kazuo Mizutani
    Sachiyo Iwata
    Katsunori Okajima
    Akira Shimane
    Masahiro Kumada
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [45] High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging
    Yokoyama, S
    Hirano, H
    Uomizu, K
    Kajiya, Y
    Tajitsu, K
    Kusumoto, K
    NEUROLOGIA MEDICO-CHIRURGICA, 2005, 45 (11) : 556 - 560
  • [46] Gd(III)-Dithiolane Gold Nanoparticles for T1-Weighted Magnetic Resonance Imaging of the Pancreas
    Holbrook, Robert J.
    Rammohan, Nikhil
    Rotz, Matthew W.
    MacRenaris, Keith W.
    Preslar, Adam T.
    Meade, Thomas J.
    NANO LETTERS, 2016, 16 (05) : 3202 - 3209
  • [47] Dynamic T1-weighted monitoring of vascularization in human carcinoma heterotransplants by magnetic resonance imaging
    Kiessling, F
    Heilmann, M
    Vosseler, S
    Lichy, M
    Krix, M
    Fink, C
    Kiessling, I
    Steinbauer, H
    Schad, L
    Fusenig, NE
    Delorme, S
    INTERNATIONAL JOURNAL OF CANCER, 2003, 104 (01) : 113 - 120
  • [48] Nanoparticle-Based Systems for T1-Weighted Magnetic Resonance Imaging Contrast Agents
    Zhu, Derong
    Liu, Fuyao
    Ma, Lina
    Liu, Dianjun
    Wang, Zhenxin
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (05): : 10591 - 10607
  • [49] Ligand-free gadolinium oxide for in vivo T1-weighted magnetic resonance imaging
    Luo, Ningqi
    Tian, Xiumei
    Yang, Chuan
    Xiao, Jun
    Hu, Wenyong
    Chen, Dihu
    Li, Li
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (29) : 12235 - 12240
  • [50] Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging
    Schindlbeck, Katharina A.
    Santaella, Anna
    Galinovic, Ivana
    Krause, Thomas
    Rocco, Andrea
    Nolte, Christian H.
    Villringer, Kersten
    Fiebach, Jochen B.
    STROKE, 2016, 47 (02) : 417 - 423