Personalized Anatomic Eye Model From T1-Weighted Volume Interpolated Gradient Echo Magnetic Resonance Imaging of Patients With Uveal Melanoma

被引:13
|
作者
Nguyen, Huu-Giao [1 ,2 ,3 ,4 ]
Sznitman, Raphael [2 ]
Maeder, Philippe [3 ]
Schalenbourg, Ann [6 ]
Peroni, Marta [1 ]
Hrbacek, Jan [1 ]
Weber, Damien C. [1 ]
Pica, Alessia [1 ]
Cuadra, Meritxell Bach [3 ,4 ,5 ]
机构
[1] Paul Scherrer Inst, ETH Domain, Proton Therapy Ctr, Villigen, Switzerland
[2] Univ Bern, ARTORG Ctr, Ophthalm Technol Lab, Bern, Switzerland
[3] Lausanne Univ Hosp, Radiol Dept, Lausanne, Switzerland
[4] Univ Lausanne, Ctr Imagerie BioMed, Med Image Anal Lab, Lausanne, Switzerland
[5] Ecole Polytech Fed Lausanne, Signal Proc Lab, Lausanne, Switzerland
[6] Univ Lausanne, Adult Ocular Oncol Unit, Jules Gonin Eye Hosp, FAA,Dept Ophthalmol, Lausanne, Switzerland
关键词
PROTON-BEAM RADIOTHERAPY; THIN-SECTION MR; AUTOMATIC SEGMENTATION; SPACE;
D O I
10.1016/j.ijrobp.2018.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We present a 3-dimensional patient-specific eye model from magnetic resonance imaging (MRI) for proton therapy treatment planning of uveal melanoma (UM). During MRI acquisition of UM patients, the point fixation can be difficult and, together with physiological blinking, can introduce motion artifacts in the images, thus challenging the model creation. Furthermore, the unclear boundary of the small objects (eg, lens, optic nerve) near the muscle or of the tumors with hemorrhage and tantalum clips can limit model accuracy. Methods and Materials: A dataset of 37 subjects, including 30 healthy eyes of volunteers and 7 eyes of UM patients, was investigated. In our previous work, active shape model was successfully applied to retinoblastoma eye segmentation in T1-weighted 3T MRI. Here, we evaluate this method in a more challenging setting, based on 1.5T MRI acquisition and different datasets of awake adult eyes with UM. The lens and cornea together with the sclera, vitreous humor, and optic nerve were automatically segmented and validated against manual delineations of a senior ocular radiation oncologist, in terms of the Dice similarity coefficient and Hausdorff distance. Results: Leave-one-out cross validation (mixing both volunteers and UM patients) yielded median Dice similarity coefficient values (respective of Hausdorff distance) of 94.5% (1.64 mm) for the sclera, 92.2% (1.73 mm) for the vitreous humor, 88.3% (1.09 mm) for the lens, and 81.9% (1.86 mm) for the optic nerve. The average computation time for an eye was 10 seconds. Conclusions: To our knowledge, our work is the first attempt to automatically segment adult eyes, including patients with UM. Our results show that automated active shape model segmentation can succeed in the presence of motion, tumors, and tantalum clips. These results are promising for inclusion in clinical practice. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [31] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Jeong Hee Yoon
    Jeong Min Lee
    Eun Sun Lee
    Jeehyun Baek
    Sangwoo Lee
    Yuji Iwadate
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 278 - 288
  • [32] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    F. Safar
    T. Kamura
    K. Okamuto
    K. Sasai
    F. Gejyo
    Abdominal Imaging, 2005, 30 : 297 - 302
  • [33] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    Safar, F
    Kamura, T
    Okamuto, K
    Sasai, K
    Gejyo, F
    ABDOMINAL IMAGING, 2005, 30 (03): : 297 - 302
  • [34] Gadolinium(III) based nanoparticles for T1-weighted magnetic resonance imaging probes
    Yang, Chang-Tong
    Padmanabhan, Parasuraman
    Gulyas, Balazs Z.
    RSC ADVANCES, 2016, 6 (65): : 60945 - 60966
  • [35] Diagnosis of symptomatic carotid plaques with T1-weighted magnetic resonance imaging and ultrasonography
    Oyama, N
    Yamada, N
    Nagatsuka, K
    Miyamoto, S
    Minematsu, K
    Naritomi, H
    STROKE, 2006, 37 (02) : 643 - 643
  • [36] Polymeric Metal Contrast Agents for T1-Weighted Magnetic Resonance Imaging of the Brain
    Foster, Dorian
    Larsen, Jessica
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2023, 9 (03): : 1224 - 1242
  • [37] Gadolinium-Incorporated Carbon Nanodots for T1-Weighted Magnetic Resonance Imaging
    Ji, Ding-Kun
    Reina, Giacomo
    Liang, Hanyu
    Zhang, Da
    Guo, Shi
    Ballesteros, Belen
    Menard-Moyon, Cecilia
    Li, Juan
    Bianco, Alberto
    ACS APPLIED NANO MATERIALS, 2021, 4 (02) : 1467 - 1477
  • [38] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [39] OPTIMIZATION OF 3-DIMENSIONAL T1-WEIGHTED GRADIENT-ECHO IMAGING OF THE CERVICAL-SPINE
    ROSS, JS
    TKACH, JA
    DILLINGER, J
    RUGGIERI, PM
    MASARYK, TJ
    MODIC, MT
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 359 - 364
  • [40] Radiomic Analysis Reveals Prognostic Information in T1-Weighted Baseline Magnetic Resonance Imaging in Patients With Glioblastoma
    Ingrisch, Michael
    Schneider, Moritz Joerg
    Noerenberg, Dominik
    de Figueiredo, Giovanna Negrao
    Maier-Hein, Klaus
    Suchorska, Bogdana
    Schueller, Ulrich
    Albert, Nathalie
    Brueckmann, Hartmut
    Reiser, Maximilian
    Tonn, Joerg-Christian
    Ertl-Wagner, Birgit
    INVESTIGATIVE RADIOLOGY, 2017, 52 (06) : 360 - 366